Literature DB >> 24618658

Evaluation of left ventricular diastolic function with a dedicated cadmium-zinc-telluride cardiac camera: comparison with Doppler echocardiography.

Alessia Gimelli1, Riccardo Liga2, Emilio Maria Pasanisi3, Assuero Giorgetti3, Gavino Marras3, Brunella Favilli3, Paolo Marzullo4.   

Abstract

AIMS: To evaluate the relationships between measures of left ventricular (LV) filling dynamics at cadmium-zinc-telluride (CZT) imaging and indexes of LV diastolic function at transthoracic echocardiography. METHODS AND
RESULTS: Two hundred and forty-seven patients underwent myocardial perfusion imaging at rest and after stress with a low-dose CZT protocol and a baseline transthoracic echocardiography study. All patients were submitted to invasive or computed coronary angiography. The peak filling rate (PFR) and the time to PFR (TPFR) were derived from gated CZT images as measures of LV filling dynamics. LV diastolic function was also evaluated at echocardiography and the presence of significantly increased LV filling pressures determined. Increased LV filling pressures at transthoracic echocardiography were evident in 103 (42%) patients. Interestingly, independently from the presence of coronary artery disease, there was a strict correlation between the presence and severity of LV diastolic dysfunction at echocardiography and CZT-derived measures of filling dynamics, i.e., PFR (P = 0.001) and TPFR (P = 0.001). At receiving operating characteristic analysis, a composite index of reduced PFR (≤2.11 end-diastolic volume s(-1)) and increased TPFR (>234 ms) showed a sensitivity of 84% and a specificity of 67% in unmasking the presence of elevated LV filling pressures at echocardiography.
CONCLUSIONS: CZT-derived measures of LV filling dynamics correlate with echocardiographic parameters of diastolic function and may identify the presence of increased LV filling pressures. Published on behalf of the European Society of Cardiology. All rights reserved.
© The Author 2014. For permissions please email: journals.permissions@oup.com.

Entities:  

Keywords:  CZT; Diastolic function; Doppler echocardiography; Filling pressures; Peak filling rate

Mesh:

Substances:

Year:  2014        PMID: 24618658     DOI: 10.1093/ehjci/jeu037

Source DB:  PubMed          Journal:  Eur Heart J Cardiovasc Imaging        ISSN: 2047-2404            Impact factor:   6.875


  14 in total

1.  Left ventricular eccentricity index measured with SPECT myocardial perfusion imaging: An additional parameter of adverse cardiac remodeling.

Authors:  Alessia Gimelli; Riccardo Liga; Alberto Clemente; Gavino Marras; Annette Kusch; Paolo Marzullo
Journal:  J Nucl Cardiol       Date:  2017-01-12       Impact factor: 5.952

2.  Influence of cardiac stress protocol on myocardial perfusion imaging accuracy: The role of exercise level on the evaluation of ischemic burden.

Authors:  Alessia Gimelli; Riccardo Liga; Emilio Maria Pasanisi; Mirta Casagranda; Michele Coceani; Paolo Marzullo
Journal:  J Nucl Cardiol       Date:  2015-03-27       Impact factor: 5.952

3.  CZT camera: moving beyond classical CAD detection?

Authors:  Thomas Hellmut Schindler
Journal:  Eur J Nucl Med Mol Imaging       Date:  2015-06       Impact factor: 9.236

4.  Interactions between myocardial sympathetic denervation and left ventricular mechanical dyssynchrony: A CZT analysis.

Authors:  Alessia Gimelli; Riccardo Liga; Francesca Menichetti; Ezio Soldati; Maria Grazia Bongiorni; Paolo Marzullo
Journal:  J Nucl Cardiol       Date:  2017-08-14       Impact factor: 5.952

5.  Detection of ischemia with early myocardial perfusion imaging: You see more if you watch before.

Authors:  Riccardo Liga; Alessia Gimelli
Journal:  J Nucl Cardiol       Date:  2016-04-13       Impact factor: 5.952

6.  Detection of non-obstructive coronary artery disease: Is post-stress diastolic dysfunction assessed by myocardial perfusion imaging a useful tool?

Authors:  Bernard Songy
Journal:  J Nucl Cardiol       Date:  2016-04-11       Impact factor: 5.952

7.  Chronotropic response to vasodilator-stress in patients submitted to myocardial perfusion imaging: impact on the accuracy in detecting coronary stenosis.

Authors:  Alessia Gimelli; Riccardo Liga; Michele Coceani; Angela Quaranta; Michele Emdin; Paolo Marzullo
Journal:  Eur J Nucl Med Mol Imaging       Date:  2015-07-21       Impact factor: 9.236

8.  Determinants of left ventricular mechanical dyssynchrony in patients submitted to myocardial perfusion imaging: A cardiac CZT study.

Authors:  Alessia Gimelli; Riccardo Liga; Assuero Giorgetti; Brunella Favilli; Emilio Maria Pasanisi; Paolo Marzullo
Journal:  J Nucl Cardiol       Date:  2015-09-04       Impact factor: 5.952

9.  Myocardial ischemia in the absence of obstructive coronary lesion: The role of post-stress diastolic dysfunction in detecting early coronary atherosclerosis.

Authors:  Alessia Gimelli; Riccardo Liga; Emilio Maria Pasanisi; Mirta Casagranda; Paolo Marzullo
Journal:  J Nucl Cardiol       Date:  2016-03-29       Impact factor: 5.952

10.  Accuracy of myocardial perfusion imaging in detecting multivessel coronary artery disease: A cardiac CZT study.

Authors:  Alessia Gimelli; Riccardo Liga; Valerio Duce; Annette Kusch; Alberto Clemente; Paolo Marzullo
Journal:  J Nucl Cardiol       Date:  2016-02-03       Impact factor: 5.952

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.