Monoenergetic extrapolation of cardiac dual energy CT for artifact reduction.

Francesco Secchi1, Carlo Nicola De Cecco2, James Vance Spearman3, Justin Robert Silverman3, Ullrich Ebersberger4, Francesco Sardanelli5, U Joseph Schoepf3.   

Abstract

BACKGROUND: Monoenergetic extrapolation of cardiac dual-energy computed tomography (DECT) could be useful in artifact reduction in clinical practice.
PURPOSE: To evaluate the potential of monoenergetic extrapolation of cardiac DECT data for reducing artifacts from metal and high iodine contrast concentration.
MATERIAL AND METHODS: With IRB approval and in HIPAA compliance, 35 patients (22 men, 61 ± 12 years) underwent cardiac DECT with dual-source CT (100 kVp and 140 kVp). Contrast material injection protocols were adapted to the patient's weight using non-ionic low-osmolar 370 mgI/mL iopromide. Datasets were transferred to a stand-alone workstation and dedicated monoenergetic analysis software was used for postprocessing. Reconstructions with the following five photon energies were generated: 40 keV, 60 keV, 80 keV, 100 keV, and 120 keV. Artifact severity was graded on a 5-point Likert scale (0, massive artifact; 5, absence of artifact). The size of artifact and image noise (expressed as HU) in anatomic structures adjacent to the artifact were measured. Quantitative and subjective image quality was compared using Friedman and Wilcoxon tests.
RESULTS: We observed artifacts arising from densely concentrated contrast material in the superior vena cava (SVC) in 18 patients, from sternal wires in 14, from bypass clips in eight, and from coronary artery stents in seven. Artifact size in monoenergetic reconstructions from 40 to 120 keV decreased from 21.3 to 19 mm for the SVC (P < 0.001), from 8.4 to 2.6 mm for sternal wires (P < 0.001), from 6.4 to 2.2 mm for bypass clips (P < 0.001), and from 5.9 to 2.7 mm for stents (P < 0.001), respectively. The quality score changed from 0.2 to 3.8 for the SVC (P < 0.001), from 0.1 to 4 for sternal wires (P < 0.001), from 0 to 3.9 for bypass clips (P < 0.001), and from 0 to 3.9 for stents (P < 0.001). Lowest noise in adjacent structures was found at 80 keV for the SVC (39.1 HU), for sternal wires (33.3), for bypass clips (26.9), and for stents (33.9).
CONCLUSION: A significant reduction of high-attenuation artifacts can be achieved by use of higher monoenergetic energy levels with cardiac DECT. However, image noise in anatomic structures affected by artifacts is lowest at 80 keV, which suggests an evaluation approach that makes use of multiple energy levels for a complete diagnosis. © The Foundation Acta Radiologica 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

Entities:  

Keywords:  Dual energy CT (DECT); artifact; monoenergetic extrapolation

Mesh:

Substances:

Year:  2014        PMID: 24615417     DOI: 10.1177/0284185114527867

Source DB:  PubMed          Journal:  Acta Radiol        ISSN: 0284-1851            Impact factor:   1.990


  16 in total

Review 1.  Dual energy computed tomography virtual monoenergetic imaging: technique and clinical applications.

Authors:  Tommaso D'Angelo; Giuseppe Cicero; Silvio Mazziotti; Giorgio Ascenti; Moritz H Albrecht; Simon S Martin; Ahmed E Othman; Thomas J Vogl; Julian L Wichmann
Journal:  Br J Radiol       Date:  2019-04-09       Impact factor: 3.039

Review 2.  New Applications of Cardiac Computed Tomography: Dual-Energy, Spectral, and Molecular CT Imaging.

Authors:  Ibrahim Danad; Zahi A Fayad; Martin J Willemink; James K Min
Journal:  JACC Cardiovasc Imaging       Date:  2015-06

Review 3.  Cardiac CT Imaging of Plaque Vulnerability: Hype or Hope?

Authors:  Martin J Willemink; Tim Leiner; Pál Maurovich-Horvat
Journal:  Curr Cardiol Rep       Date:  2016-04       Impact factor: 2.931

4.  Coronary CT angiography in patients with implanted cardiac devices: initial experience with the metal artefact reduction technique.

Authors:  Fuminari Tatsugami; Toru Higaki; Hiroaki Sakane; Wataru Fukumoto; Makoto Iida; Yasutaka Baba; Chikako Fujioka; Yasuki Kihara; So Tsushima; Kazuo Awai
Journal:  Br J Radiol       Date:  2016-09-29       Impact factor: 3.039

5.  Reduction of artifacts caused by orthopedic hardware in the spine in spectral detector CT examinations using virtual monoenergetic image reconstructions and metal-artifact-reduction algorithms.

Authors:  Nils Große Hokamp; V Neuhaus; N Abdullayev; K Laukamp; S Lennartz; A Mpotsaris; J Borggrefe
Journal:  Skeletal Radiol       Date:  2017-09-21       Impact factor: 2.199

6.  Iterative metal artefact reduction (MAR) in postsurgical chest CT: comparison of three iMAR-algorithms.

Authors:  Joel Aissa; Johannes Boos; Lino Morris Sawicki; Niklas Heinzler; Karl Krzymyk; Martin Sedlmair; Patric Kröpil; Gerald Antoch; Christoph Thomas
Journal:  Br J Radiol       Date:  2017-08-22       Impact factor: 3.039

7.  Optimisation of window settings for traditional and noise-optimised virtual monoenergetic imaging in dual-energy computed tomography pulmonary angiography.

Authors:  Tommaso D'Angelo; Andreas M Bucher; Lukas Lenga; Christophe T Arendt; Julia L Peterke; Damiano Caruso; Silvio Mazziotti; Alfredo Blandino; Giorgio Ascenti; Ahmed E Othman; Simon S Martin; Doris Leithner; Thomas J Vogl; Julian L Wichmann
Journal:  Eur Radiol       Date:  2017-10-10       Impact factor: 5.315

8.  Deep-learning-based direct synthesis of low-energy virtual monoenergetic images with multi-energy CT.

Authors:  Hao Gong; Jeffrey F Marsh; Karen N D'Souza; Nathan R Huber; Kishore Rajendran; Joel G Fletcher; Cynthia H McCollough; Shuai Leng
Journal:  J Med Imaging (Bellingham)       Date:  2021-04-19

9.  CT artifacts after contrast media injection in chest imaging: evaluation of post-processing algorithms, virtual monoenergetic images and their combination for artifact reduction.

Authors:  Amit Gupta; Verena Carola Obmann; Michelle Jordan; Simon Lennartz; Markus Michael Obmann; Nils Große Hokamp; David Zopfs; Lenhard Pennig; Gina Fürtjes; Nikhil Ramaiya; Robert Gilkeson; Kai Roman Laukamp
Journal:  Quant Imaging Med Surg       Date:  2021-01

Review 10.  Detector-based spectral CT with a novel dual-layer technology: principles and applications.

Authors:  Negin Rassouli; Maryam Etesami; Amar Dhanantwari; Prabhakar Rajiah
Journal:  Insights Imaging       Date:  2017-10-06
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.