Literature DB >> 24612938

Bruch's membrane thickness in high myopia.

Jost B Jonas1, Leonard Holbach, Songhomitra Panda-Jonas.   

Abstract

PURPOSE: To measure the thickness of Bruch's membrane (BM) and assess its associations with axial length.
METHODS: Using a light microscope, we measured the thickness of Bruch's membrane, choroid and sclera on horizontal anterior-posterior histological sections of enucleated human globes.
RESULTS: The study included 54 eyes (42 with glaucomatous optic nerve damage; 23 globes with axial length ≥26.5 mm) with a mean axial length of 26.6 ± 3.3 mm (range: 21.0-34.0 mm). In the non-highly myopic eyes, BM was significantly thicker at the pars plana region (6.6 ± 1.1 μm) than at the equator (4.1 ± 1.5 μm; p < 0.001), the midpoint between equator and posterior pole (4.1 ± 1.5 μm; p < 0.001), the parapapillary region (4.5 ± 1.0 μm; p = 0.006) or the posterior pole (4.4 ± 1.7 μm; p = 0.001). At any measurement location at or behind the ora serrata, BM thickness did not differ significantly (all p ≥ 0.40) between the non-glaucomatous non-highly myopic group and the glaucomatous non-highly myopic group, or between the non-highly myopic group and the highly myopic group. BM thickness at any location was not significantly (all p > 0.45) related to axial length. The ratio of scleral thickness to BM thickness and the ratio of choroidal thickness to BM thickness significantly decreased with longer axial length for measurements taken behind the equator.
CONCLUSIONS: BM is physiologically thickest in the pars plana, with no major thickness differences between locations at or behind the ora serrata. In contrast to choroidal and scleral thickness, BM thickness is not significantly related to axial length. Axially elongated eyes have a normal BM thickness, despite a thinned choroid and sclera.
© 2014 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  Bruch′s membrane; glaucoma; high myopia; myopization

Mesh:

Year:  2014        PMID: 24612938     DOI: 10.1111/aos.12372

Source DB:  PubMed          Journal:  Acta Ophthalmol        ISSN: 1755-375X            Impact factor:   3.761


  18 in total

1.  Choroidal neovascularization secondary to pathological myopia-macular Bruch membrane defects as prognostic factor to anti-VEGF treatment.

Authors:  João Coelho; André Ferreira; Ana Carolina Abreu; Sílvia Monteiro; Maria João Furtado; Miguel Gomes; Miguel Lume
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2021-03-21       Impact factor: 3.117

2.  Association between axial length and horizontal and vertical globe diameters.

Authors:  Jost B Jonas; Kyoko Ohno-Matsui; Leonard Holbach; Songhomitra Panda-Jonas
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2016-07-29       Impact factor: 3.117

Review 3.  [Epidemiology and anatomy of myopia].

Authors:  Jost B Jonas; Songhomitra Panda-Jonas
Journal:  Ophthalmologe       Date:  2019-06       Impact factor: 1.059

4.  Scleral and choroidal volume in relation to axial length in infants with retinoblastoma versus adults with malignant melanomas or end-stage glaucoma.

Authors:  Ling Shen; Qi Sheng You; Xiaolin Xu; Fei Gao; Zhibao Zhang; Bin Li; Jost B Jonas
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2016-04-26       Impact factor: 3.117

5.  Optic Disc-Fovea Distance, Axial Length and Parapapillary Zones. The Beijing Eye Study 2011.

Authors:  Rahul Arvo Jonas; Ya Xing Wang; Hua Yang; Jian Jun Li; Liang Xu; Songhomitra Panda-Jonas; Jost Bruno Jonas
Journal:  PLoS One       Date:  2015-09-21       Impact factor: 3.240

6.  Macular Bruch's Membrane Length and Axial Length. The Beijing Eye Study.

Authors:  Jost B Jonas; Ya Xing Wang; Qi Zhang; Yi Liu; Liang Xu; Wen Bin Wei
Journal:  PLoS One       Date:  2015-08-28       Impact factor: 3.240

7.  Three-Dimensional Evaluation of Posterior Pole and Optic Nerve Head in Myopes with Glaucoma.

Authors:  Yong Chan Kim; Kyoung In Jung; Hae-Young Lopilly Park; Chan Kee Park
Journal:  Sci Rep       Date:  2017-12-21       Impact factor: 4.379

8.  Horizontal and vertical optic disc rotation. The Beijing Eye Study.

Authors:  Yuan Yuan Fan; Jost B Jonas; Ya Xing Wang; Chang Xi Chen; Wen Bin Wei
Journal:  PLoS One       Date:  2017-05-08       Impact factor: 3.240

9.  Bruch´s membrane thickness in relationship to axial length.

Authors:  Hai Xia Bai; Ying Mao; Ling Shen; Xiao Lin Xu; Fei Gao; Zhi Bao Zhang; Bin Li; Jost B Jonas
Journal:  PLoS One       Date:  2017-08-02       Impact factor: 3.240

10.  The Location of the Deepest Point of the Eyeball Determines the Optic Disc Configuration.

Authors:  Yong Chan Kim; Younhea Jung; Hae-Young Lopilly Park; Chan Kee Park
Journal:  Sci Rep       Date:  2017-07-19       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.