Literature DB >> 24612841

Comparability of clinical wear measurements by optical 3D laser scanning in two different centers.

Thomas Stober1, Navina Heuschmid2, Gaby Zellweger3, Valentin Rousson4, Stefan Rues2, Siegward D Heintze3.   

Abstract

OBJECTIVE: The purpose of this study was to compare the use of different variables to measure the clinical wear of two denture tooth materials in two analysis centers.
METHODS: Twelve edentulous patients were provided with full dentures. Two different denture tooth materials (experimental material and control) were placed randomly in accordance with the split-mouth design. For wear measurements, impressions were made after an adjustment phase of 1-2 weeks and after 6, 12, 18, and 24 months. The occlusal wear of the posterior denture teeth of 11 subjects was assessed in two study centers by use of plaster replicas and 3D laser-scanning methods. In both centers sequential scans of the occlusal surfaces were digitized and superimposed. Wear was described by use of four different variables. Statistical analysis was performed after log-transformation of the wear data by use of the Pearson and Lin correlation and by use of a mixed linear model.
RESULTS: Mean occlusal vertical wear of the denture teeth after 24 months was between 120μm and 212μm, depending on wear variable and material. For three of the four variables, wear of the experimental material was statistically significantly less than that of the control. Comparison of the two study centers, however, revealed correlation of the wear variables was only moderate whereas strong correlation was observed among the different wear variables evaluated by each center. SIGNIFICANCE: Moderate correlation was observed for clinical wear measurements by optical 3D laser scanning in two different study centers. For the two denture tooth materials, wear measurements limited to the attrition zones led to the same qualitative assessment.
Copyright © 2014 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Clinical wear; Denture teeth; In vivo wear; Laser scanning; Wear

Mesh:

Year:  2014        PMID: 24612841     DOI: 10.1016/j.dental.2014.02.001

Source DB:  PubMed          Journal:  Dent Mater        ISSN: 0109-5641            Impact factor:   5.304


  4 in total

1.  Antagonist wear of monolithic zirconia crowns after 2 years.

Authors:  Ulrich Lohbauer; Sven Reich
Journal:  Clin Oral Investig       Date:  2016-06-09       Impact factor: 3.573

Review 2.  Wear in Antagonist Teeth Produced by Monolithic Zirconia Crowns: A Systematic Review and Meta-Analysis.

Authors:  María Fernanda Solá-Ruíz; Alejandra Baima-Moscardó; Eduardo Selva-Otaolaurruchi; José María Montiel-Company; Rubén Agustín-Panadero; Carla Fons-Badal; Lucía Fernández-Estevan
Journal:  J Clin Med       Date:  2020-04-02       Impact factor: 4.241

Review 3.  Wear Behavior of Different Generations of Zirconia: Present Literature.

Authors:  Kuljirarnat Jitwirachot; Pimduen Rungsiyakull; Julie A Holloway; Wissanee Jia-Mahasap
Journal:  Int J Dent       Date:  2022-03-07

4.  In vivo wear of CAD-CAM composite versus lithium disilicate full coverage first-molar restorations: a pilot study over 2 years.

Authors:  Jan-Frederik Güth; Kurt Erdelt; Christine Keul; Gintare Burian; Josef Schweiger; Daniel Edelhoff
Journal:  Clin Oral Investig       Date:  2020-05-12       Impact factor: 3.573

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.