Abstract

This study reviews the literature regarding the factors contributing to failures of dental implants. An electronic search was undertaken including papers from 2004 onwards. The titles and abstracts from these results were read to identify studies within the selection criteria. All reference lists of the selected studies were then hand-searched, this time without time restrictions. A narrative review discussed some findings from the first two parts where separate data from non-comparative studies may have indicated conclusions different from those possible to draw in the systematic analysis. It may be suggested that the following situations are correlated to increase the implant failure rate: a low insertion torque of implants that are planned to be immediately or early loaded, inexperienced surgeons inserting the implants, implant insertion in the maxilla, implant insertion in the posterior region of the jaws, implants in heavy smokers, implant insertion in bone qualities type III and IV, implant insertion in places with small bone volumes, use of shorter length implants, greater number of implants placed per patient, lack of initial implant stability, use of cylindrical (non-threaded) implants and prosthetic rehabilitation with implant-supported overdentures. Moreover, it may be suggested that the following situations may be correlated with an increase in the implant failure rate: use of the non-submerged technique, immediate loading, implant insertion in fresh extraction sockets, smaller diameter implants. Some recently published studies suggest that modern, moderately rough implants may present with similar results irrespective if placed in maxillas, in smoking patients or using only short implants.
© 2014 John Wiley & Sons Ltd.

Entities:  

Keywords:  associated conditions; dental implants; failure; systematic review

Mesh:

Substances:

Year:  2014        PMID: 24612346     DOI: 10.1111/joor.12157

Source DB:  PubMed          Journal:  J Oral Rehabil        ISSN: 0305-182X            Impact factor:   3.837


  65 in total

Review 1.  Efficacy of parathyroid hormone supplementation on the osseointegration of implants: a systematic review.

Authors:  Fawad Javed; Mohammad D Al Amri; Sergio Varela Kellesarian; Abdulaziz A Al-Kheraif; Fahim Vohra; José Luis Calvo-Guirado; Hans Malmstrom; Georgios E Romanos
Journal:  Clin Oral Investig       Date:  2015-12-22       Impact factor: 3.573

2.  Review finds failure rates lower for delayed loaded submerged dental implants.

Authors:  David McReynolds; Brett Duane
Journal:  Evid Based Dent       Date:  2015-12

3.  Posterior partially edentulous jaws, planning a rehabilitation with dental implants.

Authors:  Douglas R Monteiro; Emily V F Silva; Eduardo P Pellizzer; Osvaldo Magro Filho; Marcelo C Goiato
Journal:  World J Clin Cases       Date:  2015-01-16       Impact factor: 1.337

Review 4.  Accuracy assessment of dynamic computer-aided implant placement: a systematic review and meta-analysis.

Authors:  Adrià Jorba-García; Albert González-Barnadas; Octavi Camps-Font; Rui Figueiredo; Eduard Valmaseda-Castellón
Journal:  Clin Oral Investig       Date:  2021-02-26       Impact factor: 3.573

5.  Effect of periodontitis history on implant success: a long-term evaluation during supportive periodontal therapy in a university setting.

Authors:  Christian Graetz; Karim Fawzy El-Sayed; Antje Geiken; Anna Plaumann; Sonja Sälzer; Eleonore Behrens; Jörg Wiltfang; Christof E Dörfer
Journal:  Clin Oral Investig       Date:  2017-03-28       Impact factor: 3.573

6.  Bioengineered Tooth Buds Exhibit Features of Natural Tooth Buds.

Authors:  E E Smith; S Angstadt; N Monteiro; W Zhang; A Khademhosseini; P C Yelick
Journal:  J Dent Res       Date:  2018-06-07       Impact factor: 6.116

7.  Bioengineering Tooth Bud Constructs Using GelMA Hydrogel.

Authors:  Elizabeth E Smith; Pamela C Yelick
Journal:  Methods Mol Biol       Date:  2019

Review 8.  Differentiating success from survival in modern implantology--key considerations for case selection, predicting complications and obtaining consent.

Authors:  J Beaumont; G McManus; J Darcey
Journal:  Br Dent J       Date:  2016-01-15       Impact factor: 1.626

Review 9.  Diabetes and oral implant failure: a systematic review.

Authors:  B R Chrcanovic; T Albrektsson; A Wennerberg
Journal:  J Dent Res       Date:  2014-06-13       Impact factor: 6.116

10.  Dense cancellous bone as evidenced by a high HU value is predictive of late implant failure: a preliminary study.

Authors:  Ikuya Miyamoto; Tetsu Takahashi; Tatsurou Tanaka; Bunichi Hirayama; Kenko Tanaka; Toru Yamazaki; Yasuhiro Morimoto; Izumi Yoshioka
Journal:  Oral Radiol       Date:  2017-08-03       Impact factor: 1.852

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.