Literature DB >> 24610598

Endodontic instruments after torsional failure: nanoindentation test.

Ahmed Jamleh1, Alireza Sadr, Naoyuki Nomura, Arata Ebihara, Yoshio Yahata, Takao Hanawa, Junji Tagami, Hideaki Suda.   

Abstract

This study aimed to evaluate effects of torsional loading on the mechanical properties of endodontic instruments using the nanoindentation technique. ProFile (PF; size 30, taper 04; Dentsply Maillefer, Switzerland) and stainless steel (SS; size 30, taper 02; Mani, Japan) instruments were subjected to torsional test. Nanoindentation was then performed adjacent to the edge of fracture (edge) and at the cutting part beside the shank (shank). Hardness and elastic modulus were measured under 100-mN force on 100 locations at each region, and compared to those obtained from the same regions on new instruments. It showed that PF and SS instruments failed at 559 ± 67 and 596 ± 73 rotation degrees and mean maximum torque of 0.90 ± 0.07 and 0.99 ± 0.05 N-cm, respectively. Hardness and elastic modulus ranged 4.8-6.7 and 118-339 GPa in SS, and 2.7-3.2 and 52-81 GPa in PF. Significant differences between torsion-fractured and new instruments in hardness and elastic modulus were detected in the SS system used. While in PF system, the edge region after torsional fracture had significantly lower hardness and elastic modulus compared to new instruments. The local hardness and modulus of elasticity of endodontic instruments adjacent to the fracture edge are significantly reduced by torsional loading.
© 2014 Wiley Periodicals, Inc.

Entities:  

Keywords:  elastic modulus; hardness; nanoindentation; nickel-titanium; stainless steel

Mesh:

Substances:

Year:  2014        PMID: 24610598     DOI: 10.1002/sca.21139

Source DB:  PubMed          Journal:  Scanning        ISSN: 0161-0457            Impact factor:   1.932


  4 in total

Review 1.  Root dentine and endodontic instrumentation: cutting edge microscopic imaging.

Authors:  Amre R Atmeh; Timothy F Watson
Journal:  Interface Focus       Date:  2016-06-06       Impact factor: 3.906

2.  The effect of electrical treatment on cyclic fatigue of NiTi instruments.

Authors:  Mohammad Ali Saghiri; Armen Asatourian; Franklin Garcia-Godoy; James L Gutmann; Mehrdad Lotfi; Nader Sheibani
Journal:  Scanning       Date:  2014-05-05       Impact factor: 1.932

3.  Effect of NaOCl and EDTA irrigating solutions on the cyclic fatigue resistance of EdgeTaper Platinum instruments.

Authors:  Hussam Alfawaz; Abdullah Alqedairi; Maha Alhamdan; Najla Alkhzim; Shatha Alfarraj; Ahmed Jamleh
Journal:  BMC Oral Health       Date:  2022-05-22       Impact factor: 3.747

4.  Torsional resistance of three ProTaper rotary systems.

Authors:  Abdullah Alqedairi; Hussam Alfawaz; Bader Abualjadayel; Mohammad Alanazi; Ahmad Alkhalifah; Ahmed Jamleh
Journal:  BMC Oral Health       Date:  2019-06-21       Impact factor: 2.757

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.