Fully-automated quality assurance in multi-center studies using MRI phantom measurements.

Mathias Davids1, Frank G Zöllner2, Michaela Ruttorf1, Frauke Nees3, Herta Flor3, Gunter Schumann4, Lothar R Schad1.   

Abstract

Phantom measurements allow for investigating the overall quality characteristics of an MRI scanner. Especially within multicenter studies, these characteristics ensure the comparability of the results across different sites, in addition to the performance stability of a single scanner over time. This comparability requires consistent phantoms, sequence protocols, and quality assurance criteria. Within the scope of this work, a software library was implemented for fully-automated determination of important quality characteristics (comprising signal-to-noise ratio, image uniformity, ghosting artifacts, chemical shift and spatial resolution and linearity) including methods for data preparation, automated pre- and postprocessing as well as visualization and interpretation. All methods were evaluated using both synthetic images with predefined distortions and a set of 44 real phantom measurements involving eight sites and three manufacturers. Using the synthetic phantom images, predefined levels of distortion that were incorporated artificially were correctly detected by the automated routines with no more than 2.6% of relative error. In addition, the methods were applied to real phantom measurements - all data sets could be evaluated automatically considering all quality parameters as long as the acquisition protocols are followed. Shortcomings of the processability only occurred in the ghosting artifacts (39/44 evaluable) and the spatial linearity (43/44 evaluable) analysis due to gross misalignments of the phantom during image acquisition. Based on evaluation results, the accuracy of the evaluation appears to be robust to misalignments, artifacts, and distortions affecting the images, allowing for objective fully-automated evaluation and interpretation of large data set numbers.
Copyright © 2014 Elsevier Inc. All rights reserved.

Keywords:  Automated quality assurance; MRI; Multicenter study; Phantom measurement

Mesh:

Year:  2014        PMID: 24602825     DOI: 10.1016/j.mri.2014.01.017

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  15 in total

1.  Minimizing noise in pediatric task-based functional MRI; Adolescents with developmental disabilities and typical development.

Authors:  Catherine Fassbender; Prerona Mukherjee; Julie B Schweitzer
Journal:  Neuroimage       Date:  2017-01-24       Impact factor: 6.556

2.  Image quality assessment of a 1.5T dedicated magnetic resonance-simulator for radiotherapy with a flexible radio frequency coil setting using the standard American College of Radiology magnetic resonance imaging phantom test.

Authors:  Oi Lei Wong; Jing Yuan; Siu Ki Yu; Kin Yin Cheung
Journal:  Quant Imaging Med Surg       Date:  2017-04

Review 3.  [Big data and artificial intelligence for diagnostic decision support in atypical dementia].

Authors:  K Egger; M Rijntjes
Journal:  Nervenarzt       Date:  2018-08       Impact factor: 1.214

Review 4.  Standardization of Small Animal Imaging-Current Status and Future Prospects.

Authors:  Julia G Mannheim; Firat Kara; Janine Doorduin; Kerstin Fuchs; Gerald Reischl; Sayuan Liang; Marleen Verhoye; Felix Gremse; Laura Mezzanotte; Marc C Huisman
Journal:  Mol Imaging Biol       Date:  2018-10       Impact factor: 3.488

5.  Penile bulb sparing in prostate cancer radiotherapy : Dose analysis of an in-house MRI system to improve contouring.

Authors:  F Böckelmann; M Hammon; S Lettmaier; R Fietkau; C Bert; F Putz
Journal:  Strahlenther Onkol       Date:  2018-10-12       Impact factor: 3.621

Review 6.  Reproducibility and variability of quantitative magnetic resonance imaging markers in cerebral small vessel disease.

Authors:  François De Guio; Eric Jouvent; Geert Jan Biessels; Sandra E Black; Carol Brayne; Christopher Chen; Charlotte Cordonnier; Frank-Eric De Leeuw; Martin Dichgans; Fergus Doubal; Marco Duering; Carole Dufouil; Emrah Duzel; Franz Fazekas; Vladimir Hachinski; M Arfan Ikram; Jennifer Linn; Paul M Matthews; Bernard Mazoyer; Vincent Mok; Bo Norrving; John T O'Brien; Leonardo Pantoni; Stefan Ropele; Perminder Sachdev; Reinhold Schmidt; Sudha Seshadri; Eric E Smith; Luciano A Sposato; Blossom Stephan; Richard H Swartz; Christophe Tzourio; Mark van Buchem; Aad van der Lugt; Robert van Oostenbrugge; Meike W Vernooij; Anand Viswanathan; David Werring; Frank Wollenweber; Joanna M Wardlaw; Hugues Chabriat
Journal:  J Cereb Blood Flow Metab       Date:  2016-05-11       Impact factor: 6.200

Review 7.  [Quantitative perfusion imaging in magnetic resonance imaging].

Authors:  F G Zöllner; T Gaa; F Zimmer; M M Ong; P Riffel; D Hausmann; S O Schoenberg; M Weis
Journal:  Radiologe       Date:  2016-02       Impact factor: 0.635

8.  An open science resource for establishing reliability and reproducibility in functional connectomics.

Authors:  Xi-Nian Zuo; Jeffrey S Anderson; Pierre Bellec; Rasmus M Birn; Bharat B Biswal; Janusch Blautzik; John C S Breitner; Randy L Buckner; Vince D Calhoun; F Xavier Castellanos; Antao Chen; Bing Chen; Jiangtao Chen; Xu Chen; Stanley J Colcombe; William Courtney; R Cameron Craddock; Adriana Di Martino; Hao-Ming Dong; Xiaolan Fu; Qiyong Gong; Krzysztof J Gorgolewski; Ying Han; Ye He; Yong He; Erica Ho; Avram Holmes; Xiao-Hui Hou; Jeremy Huckins; Tianzi Jiang; Yi Jiang; William Kelley; Clare Kelly; Margaret King; Stephen M LaConte; Janet E Lainhart; Xu Lei; Hui-Jie Li; Kaiming Li; Kuncheng Li; Qixiang Lin; Dongqiang Liu; Jia Liu; Xun Liu; Yijun Liu; Guangming Lu; Jie Lu; Beatriz Luna; Jing Luo; Daniel Lurie; Ying Mao; Daniel S Margulies; Andrew R Mayer; Thomas Meindl; Mary E Meyerand; Weizhi Nan; Jared A Nielsen; David O'Connor; David Paulsen; Vivek Prabhakaran; Zhigang Qi; Jiang Qiu; Chunhong Shao; Zarrar Shehzad; Weijun Tang; Arno Villringer; Huiling Wang; Kai Wang; Dongtao Wei; Gao-Xia Wei; Xu-Chu Weng; Xuehai Wu; Ting Xu; Ning Yang; Zhi Yang; Yu-Feng Zang; Lei Zhang; Qinglin Zhang; Zhe Zhang; Zhiqiang Zhang; Ke Zhao; Zonglei Zhen; Yuan Zhou; Xing-Ting Zhu; Michael P Milham
Journal:  Sci Data       Date:  2014-12-09       Impact factor: 6.444

9.  A connectivity-based test-retest dataset of multi-modal magnetic resonance imaging in young healthy adults.

Authors:  Qixiang Lin; Zhengjia Dai; Mingrui Xia; Zaizhu Han; Ruiwang Huang; Gaolang Gong; Chao Liu; Yanchao Bi; Yong He
Journal:  Sci Data       Date:  2015-10-27       Impact factor: 6.444

10.  Design and first baseline data of the DZNE multicenter observational study on predementia Alzheimer's disease (DELCODE).

Authors:  Frank Jessen; Annika Spottke; Henning Boecker; Frederic Brosseron; Katharina Buerger; Cihan Catak; Klaus Fliessbach; Christiana Franke; Manuel Fuentes; Michael T Heneka; Daniel Janowitz; Ingo Kilimann; Christoph Laske; Felix Menne; Peter Nestor; Oliver Peters; Josef Priller; Verena Pross; Alfredo Ramirez; Anja Schneider; Oliver Speck; Eike Jakob Spruth; Stefan Teipel; Ruth Vukovich; Christine Westerteicher; Jens Wiltfang; Steffen Wolfsgruber; Michael Wagner; Emrah Düzel
Journal:  Alzheimers Res Ther       Date:  2018-02-07       Impact factor: 6.982

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.