Literature DB >> 24590656

CO(2) concentration in day care centres is related to wheezing in attending children.

Pedro Carreiro-Martins1, João Viegas, Ana Luisa Papoila, Daniel Aelenei, Iolanda Caires, José Araújo-Martins, João Gaspar-Marques, Maria Manuela Cano, Ana Sofia Mendes, Daniel Virella, José Rosado-Pinto, Paula Leiria-Pinto, Isabella Annesi-Maesano, Nuno Neuparth.   

Abstract

UNLABELLED: Poor ventilation at day care centres (DCCs) was already reported, although its effects on attending children are not clear. This study aimed to evaluate the association between wheezing in children and indoor CO2 (a ventilation surrogate marker) in DCC and to identify behaviours and building characteristics potentially related to CO2. In phase I, 45 DCCs from Lisbon and Oporto (Portugal) were selected through a proportional stratified random sampling. In phase II, 3 months later, 19 DCCs were further reassessed after cluster analysis for the greatest difference comparison. In both phases, children's respiratory health was assessed by ISAAC-derived questionnaires. Indoor CO2 concentrations and building characteristics of the DCC were evaluated in both phases, using complementary methods. Mixed effect models were used to analyze the data. In phase I, which included 3,186 children (mean age 3.1 ± 1.5 years), indoor CO2 concentration in the DCC rooms was associated with reported wheezing in the past 12 months (27.5 %) (adjusted odds ratio (OR) for each increase of 200 ppm 1.04, 95 % CI 1:01 to 1:07). In phase II, the association in the subsample of 1,196 children seen in 19 out of the initial 45 DCCs was not significant (adjusted OR 1.02, 95 % CI 0.96 to 1.08). Indoor CO2 concentration was inversely associated with the practices of opening windows and internal doors and with higher wind velocity. A positive trend was observed between CO2 and prevalence of reported asthma (4.7 %).
CONCLUSION: Improved ventilation is needed to achieve a healthier indoor environment in DCC.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24590656     DOI: 10.1007/s00431-014-2288-4

Source DB:  PubMed          Journal:  Eur J Pediatr        ISSN: 0340-6199            Impact factor:   3.183


  22 in total

1.  Air quality during the winter in Québec day-care centers.

Authors:  S Daneault; M Beausoleil; K Messing
Journal:  Am J Public Health       Date:  1992-03       Impact factor: 9.308

2.  Indoor air pollutants: limited-resource households and child care facilities.

Authors:  J Laquatra; L E Maxwell; M Pierce
Journal:  J Environ Health       Date:  2005-03       Impact factor: 1.179

3.  Asthma and wheezing in the first six years of life. The Group Health Medical Associates.

Authors:  F D Martinez; A L Wright; L M Taussig; C J Holberg; M Halonen; W J Morgan
Journal:  N Engl J Med       Date:  1995-01-19       Impact factor: 91.245

4.  Risk factors for acute respiratory tract infections in young Greenlandic children.

Authors:  Anders Koch; Kåre Mølbak; Preben Homøe; Per Sørensen; Thomas Hjuler; Mette Ehmer Olesen; June Pejl; Freddy Karup Pedersen; Ove Rosing Olsen; Mads Melbye
Journal:  Am J Epidemiol       Date:  2003-08-15       Impact factor: 4.897

5.  Indoor air quality and respiratory symptoms in Porto schools.

Authors:  Sílvia Fraga; Elisabete Ramos; Anabela Martins; Maria João Samúdio; Gabriela Silva; Joaquim Guedes; Eduardo Oliveira Fernandes; Henrique Barros
Journal:  Rev Port Pneumol       Date:  2008 Jul-Aug

6.  Day-care attendance and increased risk for respiratory and allergic symptoms in preschool age.

Authors:  L Hagerhed-Engman; C-G Bornehag; J Sundell; N Aberg
Journal:  Allergy       Date:  2006-04       Impact factor: 13.146

7.  School air quality related to dry cough, rhinitis and nasal patency in children.

Authors:  M Simoni; I Annesi-Maesano; T Sigsgaard; D Norback; G Wieslander; W Nystad; M Canciani; P Sestini; G Viegi
Journal:  Eur Respir J       Date:  2010-01-14       Impact factor: 16.671

8.  Risk factors for onset of asthma: a 12-year prospective follow-up study.

Authors:  Celeste Porsbjerg; Marie-Louise von Linstow; Charlotte Suppli Ulrik; Steen Nepper-Christensen; Vibeke Backer
Journal:  Chest       Date:  2006-02       Impact factor: 9.410

9.  Indoor air quality in Montréal area day-care centres, Canada.

Authors:  Mélissa St-Jean; Annie St-Amand; Nicolas L Gilbert; Julio C Soto; Mireille Guay; Karelyn Davis; Theresa W Gyorkos
Journal:  Environ Res       Date:  2012-08-01       Impact factor: 6.498

10.  Association of classroom ventilation with reduced illness absence: a prospective study in California elementary schools.

Authors:  M J Mendell; E A Eliseeva; M M Davies; M Spears; A Lobscheid; W J Fisk; M G Apte
Journal:  Indoor Air       Date:  2013-04-22       Impact factor: 5.770

View more
  6 in total

1.  Fungal DNA in dust in Swedish day care centres: associations with respiratory symptoms, fractional exhaled nitrogen oxide (FeNO) and C-reactive protein (CRP) in serum among day care centre staff.

Authors:  Dan Norbäck; Gui-Hong Cai; Ivan Kreft; Erik Lampa; Gunilla Wieslander
Journal:  Int Arch Occup Environ Health       Date:  2015-07-17       Impact factor: 3.015

2.  Indoor Air Quality in Urban and Rural Preschools in Upper Silesia, Poland: Particulate Matter and Carbon Dioxide.

Authors:  Anna Mainka; Elwira Zajusz-Zubek
Journal:  Int J Environ Res Public Health       Date:  2015-07-08       Impact factor: 3.390

3.  Effects of elevated CO2 levels on lung immune response to organic dust and lipopolysaccharide.

Authors:  David Schneberger; Upkardeep Pandher; Brooke Thompson; Shelley Kirychuk
Journal:  Respir Res       Date:  2021-04-09

Review 4.  Which Meso-Level Characteristics of Early Childhood Education and Care Centers Are Associated with Health, Health Behavior, and Well-Being of Young Children? Findings of a Scoping Review.

Authors:  Raphael M Herr; Katharina Diehl; Sven Schneider; Nina Osenbruegge; Nicole Memmer; Steffi Sachse; Stephanie Hoffmann; Benjamin Wachtler; Max Herke; Claudia R Pischke; Anna Novelli; Jennifer Hilger-Kolb
Journal:  Int J Environ Res Public Health       Date:  2021-05-07       Impact factor: 3.390

5.  Evaluation of Low-Cost Mitigation Measures Implemented to Improve Air Quality in Nursery and Primary Schools.

Authors:  Juliana P Sá; Pedro T B S Branco; Maria C M Alvim-Ferraz; Fernando G Martins; Sofia I V Sousa
Journal:  Int J Environ Res Public Health       Date:  2017-05-31       Impact factor: 3.390

6.  S3 guideline Allergy Prevention.

Authors:  Matthias V Kopp; Cathleen Muche-Borowski; Michael Abou-Dakn; Birgit Ahrens; Kirsten Beyer; Katharina Blümchen; Petra Bubel; Adam Chaker; Monika Cremer; Regina Ensenauer; Michael Gerstlauer; Uwe Gieler; Inga-Marie Hübner; Fritz Horak; Ludger Klimek; Berthold V Koletzko; Sybille Koletzko; Susanne Lau; Thomas Lob-Corzilius; Katja Nemat; Eva M J Peters; Antonio Pizzulli; Imke Reese; Claudia Rolinck-Werninghaus; Elien Rouw; Bianca Schaub; Sebastian Schmidt; Jens-Oliver Steiß; Anne Kathrin Striegel; Zsolt Szépfalusi; Dietmar Schlembach; Thomas Spindler; Christian Taube; Valérie Trendelenburg; Regina Treudler; Ulrich Umpfenbach; Christian Vogelberg; Martin Wagenmann; Anke Weißenborn; Thomas Werfel; Margitta Worm; Helmut Sitter; Eckard Hamelmann
Journal:  Allergol Select       Date:  2022-03-04
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.