Literature DB >> 22857914

Indoor air quality in Montréal area day-care centres, Canada.

Mélissa St-Jean1, Annie St-Amand, Nicolas L Gilbert, Julio C Soto, Mireille Guay, Karelyn Davis, Theresa W Gyorkos.   

Abstract

Indoor air quality (IAQ) has been understudied in day-care centres (DCCs), even though it can affect the respiratory health of children. This study was undertaken to assess IAQ in a randomly selected sample of 21 DCCs having space for at least 40 children in Montréal, Canada, and to determine associations between building characteristics and IAQ. Questionnaires on building characteristics and operation of the DCC were administered to managers. Temperature, relative humidity, and concentrations of carbon dioxide (CO(2)), formaldehyde and volatile organic compounds were measured in January and February 2008 in rooms attended by children aged between 18 and 60 months. Most DCCs (81%) had a mechanical ventilation system. Over 85% of the DCCs had a mean CO(2) concentration higher than 1000 ppm, the value generally targeted for comfort in buildings. Mean CO(2) concentrations were significantly lower in DCCs having a floor space meeting the provincial standards. The mean (standard deviation-SD) formaldehyde concentration was 22.9 (8.2) μg/m(3), with all participating DCCs being within Health Canada's Residential IAQ Guideline of 50 μg/m(3). The presence of a mechanical ventilation system and a large surface of play area per child were significantly associated with lower CO(2) levels, explaining 44% of the variance in indoor CO(2) concentrations. The presence of a mechanical ventilation system was also associated with significantly lower formaldehyde and acetaldehyde levels. Moreover, 68% of the variance in indoor acetaldehyde concentrations was explained by CO(2) levels, indicating that CO(2) was a better proxy of ventilation than the presence of a ventilation system, as this latter variable did not imply that the ventilation system was running or functioning adequately. These results demonstrate the need for on-going efforts to ensure sufficient floor space and adequate ventilation in DCCs to maintain good IAQ. Crown
Copyright © 2012. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22857914     DOI: 10.1016/j.envres.2012.07.001

Source DB:  PubMed          Journal:  Environ Res        ISSN: 0013-9351            Impact factor:   6.498


  4 in total

1.  Fungal DNA in dust in Swedish day care centres: associations with respiratory symptoms, fractional exhaled nitrogen oxide (FeNO) and C-reactive protein (CRP) in serum among day care centre staff.

Authors:  Dan Norbäck; Gui-Hong Cai; Ivan Kreft; Erik Lampa; Gunilla Wieslander
Journal:  Int Arch Occup Environ Health       Date:  2015-07-17       Impact factor: 3.015

2.  CO(2) concentration in day care centres is related to wheezing in attending children.

Authors:  Pedro Carreiro-Martins; João Viegas; Ana Luisa Papoila; Daniel Aelenei; Iolanda Caires; José Araújo-Martins; João Gaspar-Marques; Maria Manuela Cano; Ana Sofia Mendes; Daniel Virella; José Rosado-Pinto; Paula Leiria-Pinto; Isabella Annesi-Maesano; Nuno Neuparth
Journal:  Eur J Pediatr       Date:  2014-03-04       Impact factor: 3.183

3.  Cleaning Products Commonly Used in Oklahoma Family Child Care Homes: Implications for Respiratory Risk and Children's Health.

Authors:  Cassandra D Querdibitty; Marianna S Wetherill; Susan B Sisson; Bethany Williams; Kan Aithinne; Haeyn Seo; Nancy R Inhofe; Janis Campbell; Megan Slawinski; Alicia L Salvatore
Journal:  Int J Environ Res Public Health       Date:  2022-04-03       Impact factor: 3.390

4.  Ranking the environmental factors of indoor air quality of metropolitan independent coffee shops by Random Forests model.

Authors:  Yu-Wen Lin; Chin-Sheng Tang; Hsi-Chen Liu; Tzu-Ying Lee; Hsiao-Yun Huang; Tzu-An Hsu; Li-Te Chang
Journal:  Sci Rep       Date:  2022-09-26       Impact factor: 4.996

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.