Appropriate and effective anesthesia is critical, because it has a strong influence on laboratory animals, and its affect greatly impacts the experimental data. Inhalational anesthesia by endotracheal intubation is currently prevailing in general anesthesia and is prefered over injection anesthesia, especially for large laboratory animals, because it is a safe and easy control agent. However, it is not common for small laboratory animals, because of the high degree of technical skills required. We assessed the capability of use for mice of the endotracheal intubation by using the endoscope system "TESALA AE-C1" and inhalational anesthesia using a ventilator. Endotracheal intubation was successfully performed on all 10 C57BL/6 mice injected with M/M/B: 0.3/4/5 comprised of medetomidine, midazoram and butorphanol, at a dose of 0.3 mg/kg + 4.0 mg/kg + 5.0 mg/kg body weight/mouse, respectively. After the intubated mice were connected with the inhalational anesthesia circuit and the ventilator, vital signs were measured until 15 min after the connection. The data with M/M/B: 0.3/4/5 showed stable and normal values, which indicated that this new endotracheal intubation method was simple, reliable and safe, which mean that this anesthesia is favorable in regard to the animal's welfare.
Appropriate and effective anesthesia is critical, because it has a strong influence on laboratory animals, and its affect greatly impacts the experimental data. Inhalational anesthesia by endotracheal intubation is currently prevailing in general anesthesia and is prefered over injection anesthesia, especially for large laboratory animals, because it is a safe and easy control agent. However, it is not common for small laboratory animals, because of the high degree of technical skills required. We assessed the capability of use for mice of the endotracheal intubation by using the endoscope system "TESALA AE-C1" and inhalational anesthesia using a ventilator. Endotracheal intubation was successfully performed on all 10 C57BL/6 mice injected with M/M/B: 0.3/4/5 comprised of medetomidine, midazoram and butorphanol, at a dose of 0.3 mg/kg + 4.0 mg/kg + 5.0 mg/kg body weight/mouse, respectively. After the intubated mice were connected with the inhalational anesthesia circuit and the ventilator, vital signs were measured until 15 min after the connection. The data with M/M/B: 0.3/4/5 showed stable and normal values, which indicated that this new endotracheal intubation method was simple, reliable and safe, which mean that this anesthesia is favorable in regard to the animal's welfare.
Anesthesia strongly influences the experimental condition of laboratory animals, and it can
also greatly affect the experimental data. Therefore, appropriate and effective methods are
critical for safe and reliable animal experimentation [6,7,8,
12, 16, 22]. In animal experiments using laboratory rodents, such
as mice and rats, injectable anesthesia is often the general anesthesia, but it is difficult
to control the depth, the duration and the time of metabolization. Furthermore, the
inhalational anesthesia overcomes the complications of injectable methods and supplies
balanced effects, which are composed of sedation, analgesia and muscle relaxation, however,
this technique requires complex and expensive equipment [4, 6,7,8, 16, 22]. Two kinds of inhalational anesthesia
methods are generally used for experimental rodents; the face mask method and the endotracheal
intubation method. The former is simple, but relies upon the spontaneous breathing of the
animal. Because of this, the animals sometimes die of spontaneous ventilatory arrest with deep
anesthesia. In addition, it is unsuitable for open heart surgery and dysfunction of the heart
and lungs. The latter is a safer and easier method to control the depth and duration of the
anesthesia when compared to the face mask method. The operator can deliver the anesthetic and
oxygen to the alveolus using a ventilator to control the breathing rate of the rodent. Hence,
ventilatory trouble is less likely to occur due to the muscle relaxation effect of the
anesthetic, as well as using the ventilator to control the breathing rate [2, 4, 6,7,8,9, 16, 18, 22]. As a result, the inhalation anesthesia by endotracheal
intubation method is relatively safe and suitable for animals, especially those with the
cardiopulmonary dysfunctions and/or under surgical operation. However, endotracheal intubation
is not suitable for mice, because they possess a small body size, and, because the methods of
endotracheal intubation of the mice comparatively require skillful techniques and special
equipment. Therefore, a suitable system has not yet been published [3, 10, 15, 17, 19, 21]. In articles on the murine
endotracheal intubation for mice and rats [3, 10, 15, 19, 21],
consideration of the health of the animal is essential. For example, the lack of monitoring of
vital signs and/or the confirming of damage to the endotracheal mucosa was insufficient in an
experiment. In order to adhere to these requirements, we examined the endoscope system.
MATERIALS AND METHODS
Animals and housing conditions: Five males (29.3 ± 2.80 g body weight
(b.w.)) (mean ± SD) and 5 females (25.0 ± 1.3 g b.w.) of C57BL/6J mice were purchased from
Charles River Laboratories Japan Inc., (Yokohama, Japan). Animal care and experimental
procedures were approved by the Kyoto Sangyo University Committee for Animal Care and
Welfare.Premedication: In order to intubate an endotracheal tube, a mixture of
three drugs described by Kawai et al. [13], which was composed of 0.3 mg/kg b.w. of medetomidine (Domitor®,
Nippon Zenyaku Kogyo Co., Ltd., Tokyo, Japan), 4.0 mg/kg b.w. of midazoram
(Dormicum®, Astellas Pharma Inc., Tokyo, Japan) and 5.0 mg/kg b.w. of
butorphanol (Vetorphale®, Meiji Seika Kaisha, Ltd., Tokyo, Japan), was used as
premedication for immobilization, decrease in respiratory rate, muscle relaxation and
sufficient analgesia of the mice. The name of it, “M/M/B: 0.3/4/5”, was used as a
premedication for immobilization, decrease in ventilatory rate, muscle relaxation and
sufficient analgesia of the mice. Atropine sulfate (ATROPINE SULFATE Injection 0.5 mg,
Mitsubishi Tanabe Pharma Corporation, Tokyo, Japan) diluted up to 50 times with sterilized
distilled water, and it was also inoculated intraperitoneally to reduce the production of
salivary and bronchial secretions and to reduce the risk of airway blockage.Endotracheal Intubation: Endotracheal intubation was performed using an
endoscope technology from TESALA AE-C1 (AVS Co., Ltd., Tokyo, Japan.
http://www.avs.co.jp/animal/tesala/tesala3.html) (Fig.
1). 1) Endoscope probe AE-F07070 (0.7 mm in outer diameter and 70 mm long) was used for
capturing images and 20G endotracheal tube (48 mm long, KN-1008, Natsume Seisakusho, Co.,
Ltd., Tokyo, Japan) (Fig. 2). The endotracheal intubation procedure was accomplished by the following process: 1)
After the injecting of M/M/B: 0.3/4/5 as the premedication and the diluted atropine sulfate,
mice were placed on the intubation stand (KN-1014, Natsume Seisakusho, Co., Ltd.), and then,
the laryngoscope (KN-1021, Natsume Seisakusho, Co., Ltd.) was inserted to guide the
endotracheal tube insersion. 2) The endotracheal intubation was carried out while observing
the images from the probe on the monitor to confirm both the position and the form of the
larynx as well as the epiglottis. The probe covered with an endotracheal tube was inserted
into the trachea through the larynx. 3) After the position at the tip of the tube was
confirmed to be in the proper location, only the probe was removed and the tube was fixed to
a position on the upper jaw using a 3–0 silk suture. 4) The intubated tubes were connected
to the anesthetic circuit.
Fig. 1.
Overview of mouse tracheal intubation system using endoscopic system, “TESALA AE-C1”.
The data obtained from TESALA AE-C1 and MouseOx Plus are submitted into a computer and
are displayed on the monitor both as the former endoscope image and as the latter
graph of the status of the vital signs in real time.
Fig. 2.
Probe AE-F07070 and the tracheal tube for mouse tracheal intubation. The probe
“AE-F07070 (0.7 mm in outer diameter and 70 mm long)” and 20G and 48 mm long tracheal
tube were used for the mouse tracheal intubation. The probe was covered with the tube
before the intubation and was then inserted. After clarifying the success of the
tracheal intubation by the images on the PC monitor from the probe, only the probe was
pulled out. The tube was fixed to the upper jaw using a 3–0 silk suture and then
connected to the anesthetic circuit. Both bars=10 mm.
Overview of mouse tracheal intubation system using endoscopic system, “TESALA AE-C1”.
The data obtained from TESALA AE-C1 and MouseOx Plus are submitted into a computer and
are displayed on the monitor both as the former endoscope image and as the latter
graph of the status of the vital signs in real time.Probe AE-F07070 and the tracheal tube for mouse tracheal intubation. The probe
“AE-F07070 (0.7 mm in outer diameter and 70 mm long)” and 20G and 48 mm long tracheal
tube were used for the mouse tracheal intubation. The probe was covered with the tube
before the intubation and was then inserted. After clarifying the success of the
tracheal intubation by the images on the PC monitor from the probe, only the probe was
pulled out. The tube was fixed to the upper jaw using a 3–0 silk suture and then
connected to the anesthetic circuit. Both bars=10 mm.Inhalation anesthesia of the mouse using a ventilator: RC2
Rodent Anesthesia System (VetEquip, Inc., Pleasanton, CA, U.S.A.) was used as a vaporizer,
and as the anesthetic circuit, SLA Ventilator (Natsume Seisakusho, Co., Ltd.) was used as a
ventilator for small animals. In addition, 100% O2 gas was used as a carrier gas,
and the ventilator was set as follows, 250 ml flow volume/min, 150
breaths/min (BPM), and 50% I / I+E (I:intake, E:exhaust). Airway pressure in the anesthetic
circuit was also monitored continuously, and the alarm was set to sound when the pressure
exceeded 1,500 pa [3, 8, 11, 14, 20, 22]. Finally, the inhalational anesthesia was carried out using isoflurane
(Escain®, Mylan Seiyaku, Osaka, Japan). In order to control spontaneous
breathing of the mice, isoflurane was maintained at 5% concentration for 1 min after
anesthetic circuit connection and then at 2% concentration for 14 min. Atipamezole
(antisedan®, Nippon Zenyaku Kogyo Co., Ltd.), an antagonist to medetomidine, at
a dose of 1.5 mg/kg b.w. (5 times of the given dose of medetomidine) was intraperitoneally
inoculated to the mice injected with M/M/B: 0.3/4/5 immediately after the connection of the
anesthetic circuit was made to eliminate the effect of M/M/B: 0.3/4/5. After finishing the
isoflurane anesthesia, artificial respiration only by pure oxygen was continued. The mice
were disconnected from the anesthetic circuit, once the reflection and spontaneous breathing
had been stabilized, and their values of arterial oxygen saturation (SpO2,%)
displayed that of 90% or above. The endotracheal tube was removed when the reflection became
stronger and spontaneous breathing was restored, and the animals were then returned to their
cages. During the anesthesia, all mice were warmed on a hot plate while paying attention to
the state of hypothermia of the mice until they were returned to their respective cages.Measurement and record of the mice’s vital signs: Vital signs of
SpO2, heart rate (HR, beat/min) and breath rate (BR, breath/min) were measured
and recorded using MouseOx Plus® (STARR Life Sciences Corp., Pittsburgh, PA,
U.S.A.) (Fig. 1). After shaving the murine hair of
the neck using a hair clipper, the clip sensor was equipped onto the neck of the mouse to
record SpO2, HR and BR.Statistical analysis: Statistical analysis was conducted using JMP
software (SAS Institute Inc., Cary, NC, U.S.A.) for analysis. Differences on
SpO2, HR and BR between male and female were analyzed using the unpaired
student’s t.
RESULTS
The endoscopic figures of the endotracheal intubation process from TESALA AC-1 were
indicated in Fig. 3. When the probe-covered endotracheal tube was inserted into the larynx, the images of
a closed or opened epiglottis were shown on the monitor of TESALAS AE-C1 system. The opened
epiglottis could be confirmed by moving the larynx according to breath, and this made it
easier to insert the endotracheal tube into the trachea (Fig. 3A and 3B). When the epiglottis was closed, it was more difficult to insert
the tube, but it could be opened by lifting up the epiglottis gently using the tip of the
probe, TESALAS AE-C1 system (Fig. 3C).
Fig. 3.
Images in oral, trachea and esophagus from TESALA AE-C1. (A) Posterosuperior view of
larynx with opened epiglottis (B) Posterosuperior view of larynx with
opened epiglottis (C) Posterosuperior view of larynx with closed
epiglottis (D) Inside view of trachea (E) Inside view of bronchus from trachea (F)
View of incorrect intubation into esophagus. (A) was common at the beginning of the
tracheal intubation. (B) could be observed before the intubation to the trachea. (C)
was occasionally seen though. (D) was confirmed when the intubation succeeded, and (E)
was able to be also observed by advancing the probe. (F) was confirmed when the probe
was mis-inserted into the esophagus.
Images in oral, trachea and esophagus from TESALA AE-C1. (A) Posterosuperior view of
larynx with opened epiglottis (B) Posterosuperior view of larynx with
opened epiglottis (C) Posterosuperior view of larynx with closed
epiglottis (D) Inside view of trachea (E) Inside view of bronchus from trachea (F)
View of incorrect intubation into esophagus. (A) was common at the beginning of the
tracheal intubation. (B) could be observed before the intubation to the trachea. (C)
was occasionally seen though. (D) was confirmed when the intubation succeeded, and (E)
was able to be also observed by advancing the probe. (F) was confirmed when the probe
was mis-inserted into the esophagus.The endotracheal tube was intubated through the opened epiglottis, and the inside of the
trachea can be then viewed as the shape of bellows (Fig.
3D). When the origin of the bronchus is confirmed by deeply inserting the probe,
focus is needed to avoid any damage of the inside wall of the trachea or breaking of the
bronchus. (Fig. 3E). Furthermore, the smooth and
flat image indicated that the tube was mistakenly intubated into the esophagus because of
the clinging of mucosa on the tip of the probe (Fig.
3F).Results of the endotracheal intubation are shown in Table 1. All mice injected intraperitoneally with M/M/B: 0.3/4/5 were successfully
treated with the endotracheal intubation without any ventilatory arrest or difficulty. Then,
all mice were intubated and connected to the anesthetic circuit. The time of intubation was
10–60 sec (mean ± SD: 35.0 ± 16.5 sec) in the 10 mice injected with M/M/B: 0.3/4/5, and none
suffered from dyspnea. There was no difference between the amount of time taken to complete
the intubation process between male and female. The results of vital signs measured are
shown in Fig. 4. In all mice, the values of SpO2 reached up to 95% or more within 1 min
after the anesthetic circuit connection was established and those values continued for 15
min. The heart rate (HR) and the breath rate (BR) were stable at 15 min after the connection
of the circuit (489.4 ± 219.4 beat/min and 185.1 ± 101.2 breath/min). Although the BR was a
little higher than the rate set by the ventilator at 150 times/min, they appeared to be
relatively stable.
Table 1.
Result of the mouse tracheal intubation using TESALA
ID
Body Weight(g)
Sex
Kind of premedication
Time until successof intubation (sec)
Existence of troubles after intubation
3M-1
34.2
♂
M/M/B: 0.3/4/5
10
Succcess of the tracheal intubation without trouble
3M-2
28.1
♂
M/M/B: 0.3/4/5
10
Succcess of the tracheal intubation without trouble
3M-3
27.1
♂
M/M/B: 0.3/4/5
40
Succcess of the tracheal intubation without trouble
3M-4
28.8
♂
M/M/B: 0.3/4/5
30
Succcess of the tracheal intubation without trouble
3M-5
28.1
♂
M/M/B: 0.3/4/5
40
Succcess of the tracheal intubation without trouble
3M-6
24.3
♀
M/M/B: 0.3/4/5
30
Succcess of the tracheal intubation without trouble
3M-7
26.1
♀
M/M/B: 0.3/4/5
30
Succcess of the tracheal intubation without trouble
3M-8
24.1
♀
M/M/B: 0.3/4/5
50
Succcess of the tracheal intubation without trouble
3M-9
25.4
♀
M/M/B: 0.3/4/5
60
Succcess of the tracheal intubation without trouble
3M-10
22.7
♀
M/M/B: 0.3/4/5
50
Succcess of the tracheal intubation without trouble
M/M/B: 0.3/4/5 was composed of medetomidine (0.3 mg/kg) + midazoram (4.0 mg/kg) +
butorphanol (5.0 mg/kg), respectively. M/M/B: 0.3/4/5 was intraperitoneally injected
as a premedication.
Fig. 4.
Vital signs during inhalation anesthesia of tracheal-intubated mouse in groups both
pentobarbital sodium injected and M/M/B: 0.3/4/5 injected mice. (A) SpO2;
arterial oxygen saturation (%), (B) HR; heart rate (beat /min), (C) BR; breath rate
(breath /min) (A) The values of SpO2 reached to 95% or more from 1 min
after the anesthetic circuit connection until 15 min, and no significant difference
was observed in the values of SpO2 between both groups
(P>0.05). (B) However, the HR values of M/M/B: 0.3/4/5 injected
group were bigger than those of pentobarbital sodium injected group, and no
significant difference was observed between the 2 groups. (C) The BR values of M/M/B:
0.3/4/5 injected group showed relatively stable except at 2 to 4 min and at 7 min,
though they were a little bigger than that of the set by the ventilator (150
times/min). However, the low values of pentobarbital sodium injected group were shown
to be significant from 8 min until the end of the anesthesia.
M/M/B: 0.3/4/5 was composed of medetomidine (0.3 mg/kg) + midazoram (4.0 mg/kg) +
butorphanol (5.0 mg/kg), respectively. M/M/B: 0.3/4/5 was intraperitoneally injected
as a premedication.Vital signs during inhalation anesthesia of tracheal-intubated mouse in groups both
pentobarbital sodium injected and M/M/B: 0.3/4/5 injected mice. (A) SpO2;
arterial oxygen saturation (%), (B) HR; heart rate (beat /min), (C) BR; breath rate
(breath /min) (A) The values of SpO2 reached to 95% or more from 1 min
after the anesthetic circuit connection until 15 min, and no significant difference
was observed in the values of SpO2 between both groups
(P>0.05). (B) However, the HR values of M/M/B: 0.3/4/5 injected
group were bigger than those of pentobarbital sodium injected group, and no
significant difference was observed between the 2 groups. (C) The BR values of M/M/B:
0.3/4/5 injected group showed relatively stable except at 2 to 4 min and at 7 min,
though they were a little bigger than that of the set by the ventilator (150
times/min). However, the low values of pentobarbital sodium injected group were shown
to be significant from 8 min until the end of the anesthesia.
DISCUSSION
The methods of anesthesia for mice are classified roughly into 2 types, injection
anesthesia and inhalational anesthesia. The latter is also classified into 2 types, the mask
anesthesia and the anesthesia, which uses the ventilator. The mask anesthesia can be
operated without the requirement of an expensive and complicated device, but sometimes
laboratory animals can die from breathing difficulties because the gas exchange depends on
spontaneous breathing. On the other hand, though the anesthesia using the ventilator
requires endotracheal intubation, the risk of breathing trouble is quite low because
artificial breath is mechanically controlled by the ventilator. Hence, the anesthesia using
the ventilator is useful not only in general anesthesia, like large laboratory animals, such
as dogs, pigs and monkeys, but also in mice as well as general anesthesia for rodents. It
can be used for time-consuming surgeries and open heart surgeries. The endotracheal
intubation is also applicable to mice for obtaining imaging data, such as, an MRI or CT. In
this experiment, we introduced a new, easy and safe intubation method by using an endoscope
system for small rodents. M/M/B: 0.3/4/5 was used as a premedication for 5 males and 5
females. Results of the endotracheal intubation showed that the new visible method was quick
and safe (Fig. 3 and Table 1). Moreover, they also suggested 4 advantages; 1) Since the
success or failure of intubation can be determined visually, it can be performed
successfully, preventing the incorrect placement of intubation. 2) The damaging of the mouse
respiratory system during the tracheal intubation can be discovered easily, because of image
from the endoscope. 3) As a result, prevention is beforehand possible in the difficulty
during the inhalational anesthesia. And 4) Additionally, this brings the practice of the
animal welfare. The purposes of premedication are to make the animals sedative, analgesic
and musclarly-relaxed for easy tracheal intubatation before the inhalational anesthesia.
[4, 6,7,8, 16, 22]. However,
if muscle relaxation is too strong, sometimes the animals will die of dyspnea. Therefore,
the choice of anesthetics, the dosage and the injection route of the premedication greatly
influences the success or failure of the tracheal intubation method. According to the
description for M/M/B: 0.3/4/5 by Kawai et al. [13], the time until immobilization was 2.67 ± 0.58 min, and the time
required by an anesthetic stage was 5.67 ± 2.31 min. Since the mice became immobile about 3
min after the injection of M/M/B: 0.3/4/5 in this experiment as well as Kawai’s report, the
shave had begun at 3 min after the premedication and the tracheal intubation had begun at
about 8 min. Moreover, all mice inoclated with M/M/B: 0.3/4/5 showed no breathing trouble
during and/or after the tracheal intubation. In addition, vital signs in Fig. 4 showed that SpO2, HR and BR were
comparatively stable from the beginning to the end [1,
5]. Thus, we think M/M/B: 0.3/4/5 is one of the most
suitable premedication agents for murine tracheal intubation and following isoflurane
anesthesia. Mice were intraperitoneally injected with atipamezole immediately after the
connection to the circuit. This drug is an α2-antagonist and a specific reversal agent to
medetomizine. We think that atipamezole suppressed the effect of the medetomidine in M/M/B:
0.3/4/5 and made the BR of mice injected with M/M/B: 0.3/4/5, stable and balanced during the
isoflurane anesthesia. More studies are needed to outline the effects of atipamezole on
premedication and inhalational anesthesia. In this experiment, we demonstrated a new, easy,
quick and safer tracheal intubation method of inhalational anesthesia for mice using the
exceptional endoscope system, TESALAS AE-C1 and premeticaton of M/M/B: 0.3/4/5. With the
widespread use of this method, it would benefit not only for the research data, but also for
caring for the well-being of the animal, as well as the three “R”s principle for
experimentation that is being performed on animals.
Authors: E N Spoelstra; C Ince; A Koeman; V M Emons; L A Brouwer; M J A van Luyn; B H C Westerink; R Remie Journal: Lab Anim Date: 2007-01 Impact factor: 2.471
Authors: Joseph M Fuentes; Eric J Hanly; Sharon L Bachman; Alexander R Aurora; Michael R Marohn; Mark A Talamini Journal: J Surg Res Date: 2004-12 Impact factor: 2.192