Literature DB >> 24583690

A polyadenosine-coralyne complex as a novel fluorescent probe for the sensitive and selective detection of heparin in plasma.

Szu-Ying Hung1, Wei-Lung Tseng2.   

Abstract

This study presents the development of a simple, label-free, sensitive, and selective detection system for heparin based on the use of a complex of 20-repeat adenosine (A20) and coralyne. Coralyne emits relatively weak fluorescence in an aqueous solution. In the presence of A20, coralyne molecules complexed with A20 through A2-coralyne-A2 coordination. An increase in the fluorescence of coralyne was observed because coralyne remained separate from water in the hydrophobic environment of the folded A20. The presence of heparin and the formation of the coralyne-heparin complex caused coralyne to be removed from the A20-corlayne complex. Because heparin promoted coralyne dimerization, the fluorescence of coralyne decreased as a function of the concentration of added heparin. This detection method is effective because the electrostatic attraction between heparin and coralyne is substantially stronger than the coordination between A20 and coralyne in a 4-(2-hydroxyethyl)-1-piperazineethanesulfonic acid (HEPES) buffer at pH 7.0. Under optimal conditions (5 μM coralyne, 1 μM poly A20, and 10mM HEPES), this probe exhibited high selectivity (>90-fold) toward heparin over hyaluronic acid and chondroitin sulfate. The probe׳s detection limit for heparin was determined to be 4 nM (75 ng/mL) at a signal-to-noise ratio of 3. This study validates the practicality of using the A20-corlayne complex to determine the concentration of heparin in plasma.
Copyright © 2014 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Coralyne; Fluorescent sensor; Heparin; Polyadenosine; Protamine

Mesh:

Substances:

Year:  2014        PMID: 24583690     DOI: 10.1016/j.bios.2014.02.010

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  2 in total

1.  A ratiometric fluorometric heparin assay based on the use of CdTe and polyethyleneimine-coated carbon quantum dots.

Authors:  Si-Si Liang; Xu Deng; Yao-Yao Fan; Jun Li; Man Wang; Zhi-Qi Zhang
Journal:  Mikrochim Acta       Date:  2018-10-25       Impact factor: 5.833

2.  A Turn-on Fluorescence Sensor for Heparin Detection Based on a Release of Taiwan Cobra Cardiotoxin from a DNA Aptamer or Adenosine-Based Molecular Beacon.

Authors:  Yi-Jun Shi; Liang-Jun Wang; Yuan-Chin Lee; Chia-Hui Huang; Wan-Ping Hu; Long-Sen Chang
Journal:  Molecules       Date:  2018-02-19       Impact factor: 4.411

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.