Literature DB >> 30361934

A ratiometric fluorometric heparin assay based on the use of CdTe and polyethyleneimine-coated carbon quantum dots.

Si-Si Liang1,2,3,4, Xu Deng1,2,3, Yao-Yao Fan1,2,3, Jun Li1,2,3, Man Wang1,2,3, Zhi-Qi Zhang5,6,7.   

Abstract

CdTe quantum dots (QDs) were integrated with polyethyleneimine-coated carbon dots (PEI-CDs) to form a dually emitting probe for heparin. The red fluorescence of the CdTe QDs is quenched by the PEI-CDs due to electrostatic interactions. In the presence of heparin, the blue fluorescence of PEI-CDs remains unaffected, while its quenching effect on the fluorescence of CdTe QDs is strongly reduced. A ratiometric fluorometric assay was worked out. The ratio of the fluorescences at 595 and 436 nm serves as the analytical signal. Response is linear in the concentration range of 50-600 ng·mL-1 (0.1-1.2 U·mL-1) of heparin. The limit of detection is 20 ng·mL-1 (0.04 U·mL-1). This makes the method a valuable tool for heparin monitoring during postoperative and long-term care. This assay is relatively free from the interference by other analogues which commonly co-exist with heparin in samples, and it is more robust than single-wavelength based assays. Graphical abstract In the presence of heparin, the fluorescence of polyethyleneimine-coated carbon dots (PEI-CDs) at 436 nm remains unaffected, while its quenching effect on the fluorescence of CdTe at 595 nm is strongly reduced.

Entities:  

Keywords:  Carbon dots; CdTe quantum dots; Dually emitting probe; Fluorescence assay; Fluorescence quenching; Heparin; Polyethyleneimine; Ratiometric method

Mesh:

Substances:

Year:  2018        PMID: 30361934     DOI: 10.1007/s00604-018-3061-6

Source DB:  PubMed          Journal:  Mikrochim Acta        ISSN: 0026-3672            Impact factor:   5.833


  27 in total

1.  Butterfly-shaped conjugated oligoelectrolyte/graphene oxide integrated assay for light-up visual detection of heparin.

Authors:  Liping Cai; Ruoyu Zhan; Kan-Yi Pu; Xiaoying Qi; Hua Zhang; Wei Huang; Bin Liu
Journal:  Anal Chem       Date:  2011-09-29       Impact factor: 6.986

2.  A "turn-off" SERS assay of heparin with high selectivity based on heparin-peptide complex and Raman labelled gold nanoparticles.

Authors:  Gan Qu; Guannan Zhang; Zitong Wu; Aiguo Shen; Jianbo Wang; Jiming Hu
Journal:  Biosens Bioelectron       Date:  2014-04-18       Impact factor: 10.618

3.  Ratiometric ultrasensitive fluorometric detection of ascorbic acid using a dually emitting CdSe@SiO2@CdTe quantum dot hybrid.

Authors:  Jing Wang; Xiao Peng; Daquan Li; Xiaochun Jiang; Zaifa Pan; Aimin Chen; Liang Huang; Jun Hu
Journal:  Mikrochim Acta       Date:  2017-12-08       Impact factor: 5.833

4.  Ratiometric fluorometric determination of the anthrax biomarker 2,6-dipicolinic acid by using europium(III)-doped carbon dots in a test stripe.

Authors:  Mingcong Rong; Xiangzhou Deng; Siting Chi; Longzhen Huang; Youbin Zhou; Yune Shen; Xi Chen
Journal:  Mikrochim Acta       Date:  2018-03-01       Impact factor: 5.833

5.  Ultrasensitive detection of heparin by exploiting the silver nanoparticle-enhanced fluorescence of graphitic carbon nitride (g-C3N4) quantum dots.

Authors:  Qiao Cheng; Yu He; Yili Ge; Jiangang Zhou; Gongwu Song
Journal:  Mikrochim Acta       Date:  2018-06-20       Impact factor: 5.833

6.  Mallard blue: a high-affinity selective heparin sensor that operates in highly competitive media.

Authors:  Stephen M Bromfield; Anna Barnard; Paola Posocco; Maurizio Fermeglia; Sabrina Pricl; David K Smith
Journal:  J Am Chem Soc       Date:  2013-02-13       Impact factor: 15.419

7.  One-Step Synthesis of Water-Dispersible and Biocompatible Silicon Nanoparticles for Selective Heparin Sensing and Cell Imaging.

Authors:  Su-Dai Ma; Yong-Lei Chen; Jie Feng; Juan-Juan Liu; Xian-Wei Zuo; Xing-Guo Chen
Journal:  Anal Chem       Date:  2016-10-17       Impact factor: 6.986

8.  Turn-on fluorescence sensor for the detection of heparin based on rhodamine B-modified polyethyleneimine-graphene oxide complex.

Authors:  Jinshui Liu; Guoning Liu; Wenxiu Liu; Yiru Wang
Journal:  Biosens Bioelectron       Date:  2014-09-16       Impact factor: 10.618

9.  Adsorption of anionic MO or cationic MB from MO/MB mixture using polyacrylonitrile fiber hydrothermally treated with hyperbranched polyethylenimine.

Authors:  You Fan; Hua-Ji Liu; Yao Zhang; Yu Chen
Journal:  J Hazard Mater       Date:  2014-09-30       Impact factor: 10.588

10.  A "turn on" fluorescent probe for heparin and its oversulfated chondroitin sulfate contaminant.

Authors:  Yubin Ding; Leilei Shi; Hui Wei
Journal:  Chem Sci       Date:  2015-07-23       Impact factor: 9.825

View more
  2 in total

1.  Colorimetric and fluorometric aggregation-based heparin assay by using gold nanoclusters and gold nanoparticles.

Authors:  Zhipeng Zhang; Sha Li; Pengcheng Huang; Jiayu Feng; Fang-Ying Wu
Journal:  Mikrochim Acta       Date:  2019-11-16       Impact factor: 5.833

2.  Green fluorescent carbon quantum dots functionalized with polyethyleneimine, and their application to aptamer-based determination of thrombin and ATP.

Authors:  Ying Guo; Juncai Zhang; Weihong Zhang; Daodao Hu
Journal:  Mikrochim Acta       Date:  2019-10-25       Impact factor: 5.833

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.