Literature DB >> 24582804

Cortical measurements of the tibia from high resolution peripheral quantitative computed tomography images: a comparison with synchrotron radiation micro-computed tomography.

Agnès Ostertag1, Françoise Peyrin2, Sylvie Fernandez1, Jean Denis Laredo3, Marie Christine de Vernejoul1, Christine Chappard4.   

Abstract

High resolution-peripheral quantitative computed tomography (HR-pQCT) measurements are carried out in clinical research protocols to analyze cortical bone. Micro-computed tomography (micro-CT) is a standard tool for ex vivo examination of bone in 3D. The aim of this work was to evaluate cortical measurements derived from HR-pQCT images compared to those from synchrotron radiation (SR) micro-CT in a distal position (4.2 cm from the distal pilon). Twenty-nine tibia specimens were scanned with HR-pQCT using protocols provided by the manufacturer. The standard measured outcomes included volumetric bone density (gHA/cm(3)) of the cortical region (Dcomp), and the cortical thickness (Ct.Th, mm). New features, such as cortical porosity (Ct.Po) and mean pore diameter (Ct.Po.Dm), were measured by an auto-contouring process. All tibias were harvested from the posterior region and imaged with SR micro-CT (voxel size=7.5 μm). The cortical thickness, (Ct.Thmicro-CT), porosity (PoV/TV), pore diameter, pore spacing, pore number, and degree of mineralization of bone (DMB) were obtained for SR micro-CT images. For standard measurements on HR-pQCT images, site matched analyses with micro-CT were completed to obtain Dcomplocal and Ct.Thlocal. Dcomp was highly correlated to PoV/TV (r=-0.84, p<10(-4)) but not to DMB. Dcomplocal was correlated to PoV/TV (r=-0.72, p<10(-4)) and to DMB (r=0.40, p>0.05). Ct.Thlocal and Ct.Thmicro-CT were moderately correlated (r=0.53, p<0.01). Ct.Th and Ct.Po results from the autocontouring process are influenced by the level of trabecularization of the cortical bone and need manual correction of the endosteal contour. Distal tibia is a reliable region to study cortical bone with Dcomp as the best parameter because it reflects both the micro-porosity (Havers canals) and macro-porosity (resorption lacunae) of the cortical bone.
Copyright © 2014 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Cortical bone; High resolution peripheral quantitative computed tomography; Synchrotron radiation micro-computed tomography; X-ray

Mesh:

Year:  2014        PMID: 24582804     DOI: 10.1016/j.bone.2014.02.009

Source DB:  PubMed          Journal:  Bone        ISSN: 1873-2763            Impact factor:   4.398


  5 in total

1.  Role of endocortical contouring methods on precision of HR-pQCT-derived cortical micro-architecture in postmenopausal women and young adults.

Authors:  C E Kawalilak; J D Johnston; D M L Cooper; W P Olszynski; S A Kontulainen
Journal:  Osteoporos Int       Date:  2015-08-08       Impact factor: 4.507

Review 2.  Quantitative imaging methods in osteoporosis.

Authors:  Ling Oei; Fjorda Koromani; Fernando Rivadeneira; M Carola Zillikens; Edwin H G Oei
Journal:  Quant Imaging Med Surg       Date:  2016-12

3.  Deep learning methods allow fully automated segmentation of metacarpal bones to quantify volumetric bone mineral density.

Authors:  Lukas Folle; Timo Meinderink; David Simon; Anna-Maria Liphardt; Gerhard Krönke; Georg Schett; Arnd Kleyer; Andreas Maier
Journal:  Sci Rep       Date:  2021-05-06       Impact factor: 4.379

4.  Large cortical bone pores in the tibia are associated with proximal femur strength.

Authors:  Gianluca Iori; Johannes Schneider; Andreas Reisinger; Frans Heyer; Laura Peralta; Caroline Wyers; Melanie Gräsel; Reinhard Barkmann; Claus C Glüer; J P van den Bergh; Dieter Pahr; Kay Raum
Journal:  PLoS One       Date:  2019-04-17       Impact factor: 3.240

5.  Cortical bone density by quantitative computed tomography mirrors disorders of bone structure in bone biopsy of non-dialysis CKD patients.

Authors:  Amandha L Bittencourt; Maria Eugênia F Canziani; Larissa D B R Costa; Carlos E Rochitte; Aluizio B Carvalho
Journal:  Bone Rep       Date:  2022-01-11
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.