Literature DB >> 24580080

Legionella detection by culture and qPCR: Comparing apples and oranges.

Harriet Whiley1, Michael Taylor1.   

Abstract

Legionella spp. are the causative agent of Legionnaire's disease and an opportunistic pathogen of significant public health concern. Identification and quantification from environmental sources is crucial for identifying outbreak origins and providing sufficient information for risk assessment and disease prevention. Currently there are a range of methods for Legionella spp. quantification from environmental sources, but the two most widely used and accepted are culture and real-time polymerase chain reaction (qPCR). This paper provides a review of these two methods and outlines their advantages and limitations. Studies from the last 10 years which have concurrently used culture and qPCR to quantify Legionella spp. from environmental sources have been compiled. 26/28 studies detected Legionella at a higher rate using qPCR compared to culture, whilst only one study detected equivalent levels of Legionella spp. using both qPCR and culture. Aggregating the environmental samples from all 28 studies, 2856/3967 (72%) tested positive for the presence of Legionella spp. using qPCR and 1331/3967 (34%) using culture. The lack of correlation between methods highlights the need to develop an acceptable standardized method for quantification that is sufficient for risk assessment and management of this human pathogen.

Entities:  

Keywords:  Culture; L. pneumophila; Legionella spp.; PCR; environmental samples; public health; qPCR; risk assessment

Mesh:

Year:  2014        PMID: 24580080     DOI: 10.3109/1040841X.2014.885930

Source DB:  PubMed          Journal:  Crit Rev Microbiol        ISSN: 1040-841X            Impact factor:   7.624


  31 in total

1.  Abundance of Naegleria fowleri in roof-harvested rainwater tank samples from two continents.

Authors:  Monique Waso; Penelope Heather Dobrowsky; Kerry Ann Hamilton; Geoffrey Puzon; Haylea Miller; Wesaal Khan; Warish Ahmed
Journal:  Environ Sci Pollut Res Int       Date:  2017-12-11       Impact factor: 4.223

2.  Legionella: A Promising Supplementary Indicator of Microbial Drinking Water Quality in Municipal Engineered Water Systems.

Authors:  Chiqian Zhang; Jingrang Lu
Journal:  Front Environ Sci       Date:  2021-11-10

3.  Legionella and other opportunistic pathogens in full-scale chloraminated municipal drinking water distribution systems.

Authors:  Chiqian Zhang; Ian Struewing; Jatin H Mistry; David G Wahman; Jonathan Pressman; Jingrang Lu
Journal:  Water Res       Date:  2021-08-19       Impact factor: 13.400

4.  Ten Questions Concerning the Aerosolization and Transmission of Legionella in the Built Environment.

Authors:  Aaron J Prussin; David Otto Schwake; Linsey C Marr
Journal:  Build Environ       Date:  2017-06-13       Impact factor: 6.456

5.  Use of Fourier-Transform Infrared Spectroscopy With IR Biotyper® System for Legionella pneumophila Serogroups Identification.

Authors:  Maria Rosaria Pascale; Francesco Bisognin; Marta Mazzotta; Luna Girolamini; Federica Marino; Paola Dal Monte; Miriam Cordovana; Maria Scaturro; Maria Luisa Ricci; Sandra Cristino
Journal:  Front Microbiol       Date:  2022-04-26       Impact factor: 6.064

Review 6.  Environmental (Saprozoic) Pathogens of Engineered Water Systems: Understanding Their Ecology for Risk Assessment and Management.

Authors:  Nicholas J Ashbolt
Journal:  Pathogens       Date:  2015-06-19

7.  Comparing methods of determining Legionella spp. in complex water matrices.

Authors:  Álvaro Díaz-Flores; Juan Carlos Montero; Francisco Javier Castro; Eva María Alejandres; Carmen Bayón; Inmaculada Solís; Roberto Fernández-Lafuente; Guillermo Rodríguez
Journal:  BMC Microbiol       Date:  2015-04-29       Impact factor: 3.605

8.  Quantification of Legionella pneumophila by qPCR and culture in tap water with different concentrations of residual disinfectants and heterotrophic bacteria.

Authors:  Maura J Donohue
Journal:  Sci Total Environ       Date:  2021-02-06       Impact factor: 10.753

9.  Opportunistic Pathogens Mycobacterium Avium Complex (MAC) and Legionella spp. Colonise Model Shower.

Authors:  Harriet Whiley; Steven Giglio; Richard Bentham
Journal:  Pathogens       Date:  2015-07-24

10.  Limitations of Using Propidium Monoazide with qPCR to Discriminate between Live and Dead Legionella in Biofilm Samples.

Authors:  Michael J Taylor; Richard H Bentham; Kirstin E Ross
Journal:  Microbiol Insights       Date:  2014-09-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.