Literature DB >> 24572492

Combined supine and prone myocardial perfusion single-photon emission computed tomography with a cadmium zinc telluride camera for detection of coronary artery disease.

Yoshiko Nishiyama1, Masao Miyagawa, Naoto Kawaguchi, Masashi Nakamura, Tomoyuki Kido, Akira Kurata, Teruhito Kido, Akiyoshi Ogimoto, Jitsuo Higaki, Teruhito Mochizuki.   

Abstract

BACKGROUND: Myocardial perfusion SPECT (MPS) traditionally requires the patient to be in the supine position, but diaphragmatic attenuation of the inferior wall reduces test specificity. The aim of this study was to assess the feasibility of combined MPS in the supine and prone positions using a novel cadmium zinc telluride (CZT) camera. METHODS AND
RESULTS: A total of 276 consecutive patients with suspected/known coronary artery disease (CAD) who underwent single-day (99m)Tc-tetrofosmin or (99m)Tc-sestamibi stress/rest CZT SPECT, were enrolled in the study. Seventy-six underwent coronary angiography. Five-minute scan in the supine (S) position and thereafter in the prone (P) position produced images that were visually interpreted to obtain summed stress (SSS) and rest (SRS) scores. A combined stress score (C-SSS) was calculated by grouping anterior perfusion defects observed during supine imaging with inferior half segments observed during prone imaging. The SSS for the supine, prone, and combined protocols were 9±8, 7±8, and 7±8, respectively (P<0.0001). The SRS were 5±8, 4±7, and 6±7, respectively (P=0.005). The area under the ROC curve for the S-SSS, P-SSS, and C-SSS scores was 0.815 (95% CI: 0.713-0.917), 0.813 (0.711-0.914), and 0.872 (0.783-0.961), respectively. Corresponding sensitivities and specificities for detecting CAD were 87% and 50%, 80% and 77%, and 85% and 82%, respectively. C-SSS had significantly better specificity and accuracy than S-SSS (P<0.05).
CONCLUSIONS: Combined imaging with a CZT camera is suitable for routine clinical MPS and provides greater diagnostic accuracy than supine imaging alone.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24572492     DOI: 10.1253/circj.cj-13-1316

Source DB:  PubMed          Journal:  Circ J        ISSN: 1346-9843            Impact factor:   2.993


  15 in total

1.  Prospective diagnostic performance of semiconductor SPECT myocardial perfusion imaging: wall thickening analysis reduces the need for an additional prone acquisition.

Authors:  Loïc Djaileb; Benjamin Dubois; Nicolas de Leiris; Julien Leenhardt; Marjorie Canu; Olivier Phan Sy; Adrien Carabelli; Bastien Boussat; Laurent Dumas; Alexis Broisat; Gérald Vanzetto; Daniel Fagret; Catherine Ghezzi; Gilles Barone-Rochette; Laurent M Riou
Journal:  Eur J Nucl Med Mol Imaging       Date:  2019-07-18       Impact factor: 9.236

2.  Factors affecting appearance of a normal myocardial perfusion scan.

Authors:  Piotr Slomka; Guido Germano
Journal:  J Nucl Cardiol       Date:  2017-03-30       Impact factor: 5.952

3.  Diagnostic implications of CZT SPECT and impact of CT attenuation correction.

Authors:  Andrew Peters; Jeevan Kumar; Pravin V Patil
Journal:  J Nucl Cardiol       Date:  2017-06-23       Impact factor: 5.952

4.  Quantification with normal limits: New cameras and low-dose imaging.

Authors:  Piotr J Slomka; Mathieu Rubeaux; Guido Germano
Journal:  J Nucl Cardiol       Date:  2016-06-14       Impact factor: 5.952

5.  Normal Databases for the Relative Quantification of Myocardial Perfusion.

Authors:  Mathieu Rubeaux; Yuan Xu; Guido Germano; Daniel S Berman; Piotr J Slomka
Journal:  Curr Cardiovasc Imaging Rep       Date:  2016-06-30

6.  Differentiation of myocardial ischemia and infarction assessed by dynamic computed tomography perfusion imaging and comparison with cardiac magnetic resonance and single-photon emission computed tomography.

Authors:  Yuki Tanabe; Teruhito Kido; Teruyoshi Uetani; Akira Kurata; Tamami Kono; Akiyoshi Ogimoto; Masao Miyagawa; Tsutomu Soma; Kenya Murase; Hirotaka Iwaki; Teruhito Mochizuki
Journal:  Eur Radiol       Date:  2016-02-06       Impact factor: 5.315

Review 7.  Performance of cardiac cadmium-zinc-telluride gamma camera imaging in coronary artery disease: a review from the cardiovascular committee of the European Association of Nuclear Medicine (EANM).

Authors:  Denis Agostini; Pierre-Yves Marie; Simona Ben-Haim; François Rouzet; Bernard Songy; Alessandro Giordano; Alessia Gimelli; Fabien Hyafil; Roberto Sciagrà; Jan Bucerius; Hein J Verberne; Riemer H J A Slart; Oliver Lindner; Christopher Übleis; Marcus Hacker
Journal:  Eur J Nucl Med Mol Imaging       Date:  2016-08-19       Impact factor: 9.236

8.  Diagnostic value of stress thallium-201/rest technetium-99m-sestamibi sequential dual isotope high-speed myocardial perfusion imaging for the detection of haemodynamically relevant coronary artery stenosis.

Authors:  Gilles Barone-Rochette; Feras Zoreka; Loïc Djaileb; Nicolas Piliero; Alex Calizzano; Jean Louis Quesada; Alexis Broisat; Laurent Riou; Jacques Machecourt; Daniel Fagret; Gerald Vanzetto; Catherine Ghezzi
Journal:  J Nucl Cardiol       Date:  2018-01-29       Impact factor: 5.952

9.  Assessment of Myocardial CZT SPECT Recording in a Forward-Leaning Bikerlike Position.

Authors:  Mathieu Perrin; Véronique Roch; Marine Claudin; Antoine Verger; Henri Boutley; Gilles Karcher; Cédric Baumann; Nicolas Veran; Pierre-Yves Marie; Laetitia Imbert
Journal:  J Nucl Med       Date:  2018-11-02       Impact factor: 10.057

10.  Diagnostic performance of myocardial perfusion imaging with conventional and CZT single-photon emission computed tomography in detecting coronary artery disease: A meta-analysis.

Authors:  Valeria Cantoni; Roberta Green; Wanda Acampa; Emilia Zampella; Roberta Assante; Carmela Nappi; Valeria Gaudieri; Teresa Mannarino; Renato Cuocolo; Eugenio Di Vaia; Mario Petretta; Alberto Cuocolo
Journal:  J Nucl Cardiol       Date:  2019-05-14       Impact factor: 5.952

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.