Literature DB >> 24567041

Environmental contamination, product contamination and workers exposure using a robotic system for antineoplastic drug preparation.

Paul J M Sessink1, Gisèle M Leclercq2, Dominique-Marie Wouters2, Loïc Halbardier2, Chaïma Hammad2, Nassima Kassoul2.   

Abstract

Environmental contamination, product contamination and technicians exposure were measured following preparation of iv bags with cyclophosphamide using the robotic system CytoCare. Wipe samples were taken inside CytoCare, in the clean room environment, from vials, and prepared iv bags including ports and analysed for contamination with cyclophosphamide. Contamination with cyclophosphamide was also measured in environmental air and on the technicians hands and gloves used for handling the drugs. Exposure of the technicians to cyclophosphamide was measured by analysis of cyclophosphamide in urine. Contamination with cyclophosphamide was mainly observed inside CytoCare, before preparation, after preparation and after daily routine cleaning. Contamination outside CytoCare was incidentally found. All vials with reconstituted cyclophosphamide entering CytoCare were contaminated on the outside but vials with powdered cyclophosphamide were not contaminated on the outside. Contaminated bags entering CytoCare were also contaminated after preparation but non-contaminated bags were not contaminated after preparation. Cyclophosphamide was detected on the ports of all prepared bags. Almost all outer pairs of gloves used for preparation and daily routine cleaning were contaminated with cyclophosphamide. Cyclophosphamide was not found on the inner pairs of gloves and on the hands of the technicians. Cyclophosphamide was not detected in the stationary and personal air samples and in the urine samples of the technicians. CytoCare enables the preparation of cyclophosphamide with low levels of environmental contamination and product contamination and no measurable exposure of the technicians.
© The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

Entities:  

Keywords:  Antineoplastic agents; cyclophosphamide; drug preparation; hospital pharmacies; robotic systems; surface contamination; workers exposure

Mesh:

Substances:

Year:  2014        PMID: 24567041     DOI: 10.1177/1078155214522840

Source DB:  PubMed          Journal:  J Oncol Pharm Pract        ISSN: 1078-1552            Impact factor:   1.809


  11 in total

Review 1.  Environmental monitoring by surface sampling for cytotoxics: a review.

Authors:  Petit Marie; Curti Christophe; Roche Manon; Montana Marc; Bornet Charleric; Vanelle Patrice
Journal:  Environ Monit Assess       Date:  2017-01-06       Impact factor: 2.513

Review 2. 

Authors:  Céline Poupeau; Christel Roland; Jean-François Bussières
Journal:  Can J Hosp Pharm       Date:  2016-10-31

Review 3.  Automated compounding technology and workflow solutions for the preparation of chemotherapy: a systematic review.

Authors:  Sarah Batson; Stephen A Mitchell; Davina Lau; Michela Canobbio; Anna de Goede; Inderjit Singh; Ulrich Loesch
Journal:  Eur J Hosp Pharm       Date:  2019-08-21

4.  Surface wipe sampling for antineoplastic (chemotherapy) and other hazardous drug residue in healthcare settings: Methodology and recommendations.

Authors:  Thomas H Connor; Matthew D Zock; Amy H Snow
Journal:  J Occup Environ Hyg       Date:  2016-09       Impact factor: 2.155

Review 5.  A review of high performance liquid chromatographic-mass spectrometric urinary methods for anticancer drug exposure of health care workers.

Authors:  Patricia I Mathias; Thomas H Connor; Clayton B'Hymer
Journal:  J Chromatogr B Analyt Technol Biomed Life Sci       Date:  2017-06-19       Impact factor: 3.205

6.  Performance evaluation of the compounding robot, APOTECAchemo, for injectable anticancer drugs in a Japanese hospital.

Authors:  Takuya Iwamoto; Takuya Morikawa; Miki Hioki; Hirofumi Sudo; Demis Paolucci; Masahiro Okuda
Journal:  J Pharm Health Care Sci       Date:  2017-04-24

7.  The assessment of environmental and external cross-contamination in preparing ready-to-administer cytotoxic drugs: a comparison between a robotic system and conventional manual production.

Authors:  Annabel Werumeus Buning; Tjerk H Geersing; Mirjam Crul
Journal:  Int J Pharm Pract       Date:  2019-09-06

8.  Environmental assessment of cytotoxic drugs in healthcare settings: protocol for a systematic review and meta-analysis.

Authors:  Laila Al Alawi; Elpidoforos S Soteriades; Marilia Silva Paulo; Linda Östlundh; Michal Grivna; Fatima Al Maskari; Rami H Al-Rifai
Journal:  Syst Rev       Date:  2020-10-19

Review 9.  Closed-system drug-transfer devices plus safe handling of hazardous drugs versus safe handling alone for reducing exposure to infusional hazardous drugs in healthcare staff.

Authors:  Kurinchi Selvan Gurusamy; Lawrence Mj Best; Cynthia Tanguay; Elaine Lennan; Mika Korva; Jean-François Bussières
Journal:  Cochrane Database Syst Rev       Date:  2018-03-27

Review 10.  Exposure to Antineoplastic Drugs in Occupational Settings: A Systematic Review of Biological Monitoring Data.

Authors:  Veruscka Leso; Cristina Sottani; Carolina Santocono; Francesco Russo; Elena Grignani; Ivo Iavicoli
Journal:  Int J Environ Res Public Health       Date:  2022-03-21       Impact factor: 3.390

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.