Roelof van Silfhout1, Anton Kachatkou1, Elena Groppo2, Carlo Lamberti2, Wim Bras3.
Abstract
The simultaneous and active feedback stabilization of X-ray beam position and monochromatic beam flux during EXAFS scans at the titanium K-edge as produced by a double-crystal monochromator beamline is reported. The feedback is generated using two independent feedback loops using separate beam flux and position measurements. The flux is stabilized using a fast extremum-searching algorithm that is insensitive to changes in the synchrotron ring current and energy-dependent monochromator output. Corrections of beam height are made using an innovative transmissive beam position monitor instrument. The efficacy of the feedback stabilization method is demonstrated by comparing the measurements of EXAFS spectra on inhomogeneous diluted Ti-containing samples with and without feedback applied.Keywords: EXAFS; Ti K-edge; beam intensity stabilization; beam position control; monochromator
Year: 2014 PMID: 24562562 DOI: 10.1107/S1600577513034747
Source DB: PubMed Journal: J Synchrotron Radiat ISSN: 0909-0495 Impact factor: 2.616