Literature DB >> 24560276

Despeckle filtering software toolbox for ultrasound imaging of the common carotid artery.

Christos P Loizou1, Charoula Theofanous2, Marios Pantziaris3, Takis Kasparis4.   

Abstract

Ultrasound imaging of the common carotid artery (CCA) is a non-invasive tool used in medicine to assess the severity of atherosclerosis and monitor its progression through time. It is also used in border detection and texture characterization of the atherosclerotic carotid plaque in the CCA, the identification and measurement of the intima-media thickness (IMT) and the lumen diameter that all are very important in the assessment of cardiovascular disease (CVD). Visual perception, however, is hindered by speckle, a multiplicative noise, that degrades the quality of ultrasound B-mode imaging. Noise reduction is therefore essential for improving the visual observation quality or as a pre-processing step for further automated analysis, such as image segmentation of the IMT and the atherosclerotic carotid plaque in ultrasound images. In order to facilitate this preprocessing step, we have developed in MATLAB(®) a unified toolbox that integrates image despeckle filtering (IDF), texture analysis and image quality evaluation techniques to automate the pre-processing and complement the disease evaluation in ultrasound CCA images. The proposed software, is based on a graphical user interface (GUI) and incorporates image normalization, 10 different despeckle filtering techniques (DsFlsmv, DsFwiener, DsFlsminsc, DsFkuwahara, DsFgf, DsFmedian, DsFhmedian, DsFad, DsFnldif, DsFsrad), image intensity normalization, 65 texture features, 15 quantitative image quality metrics and objective image quality evaluation. The software is publicly available in an executable form, which can be downloaded from http://www.cs.ucy.ac.cy/medinfo/. It was validated on 100 ultrasound images of the CCA, by comparing its results with quantitative visual analysis performed by a medical expert. It was observed that the despeckle filters DsFlsmv, and DsFhmedian improved image quality perception (based on the expert's assessment and the image texture and quality metrics). It is anticipated that the system could help the physician in the assessment of cardiovascular image analysis.
Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Keywords:  Carotid artery; Despeckling; Image; Speckle; Texture analysis; Ultrasound

Mesh:

Year:  2014        PMID: 24560276     DOI: 10.1016/j.cmpb.2014.01.018

Source DB:  PubMed          Journal:  Comput Methods Programs Biomed        ISSN: 0169-2607            Impact factor:   5.428


  10 in total

1.  Hybrid Laplacian Gaussian Based Speckle Removal in SAR Image Processing.

Authors:  A Glory Sujitha; Dr P Vasuki; A Amala Deepan
Journal:  J Med Syst       Date:  2019-06-11       Impact factor: 4.460

2.  Consistent reconstruction of 4D fetal heart ultrasound images to cope with fetal motion.

Authors:  Christine Tanner; Barbara Flach; Céline Eggenberger; Oliver Mattausch; Michael Bajka; Orcun Goksel
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-06-20       Impact factor: 2.924

3.  Feature Enhancement in Medical Ultrasound Videos Using Contrast-Limited Adaptive Histogram Equalization.

Authors:  Prerna Singh; Ramakrishnan Mukundan; Rex De Ryke
Journal:  J Digit Imaging       Date:  2020-02       Impact factor: 4.056

4.  Evaluation of carotid intima media thickness measurement from ultrasound images.

Authors:  B Smitha; Dhanraj Yadav; Paul K Joseph
Journal:  Med Biol Eng Comput       Date:  2022-01-06       Impact factor: 2.602

5.  Endorectal ultrasound radiomics in locally advanced rectal cancer patients: despeckling and radiotherapy response prediction using machine learning.

Authors:  Samira Abbaspour; Hamid Abdollahi; Hossein Arabalibeik; Maedeh Barahman; Amir Mohammad Arefpour; Pedram Fadavi; Mohammadreza Ay; Seied Rabi Mahdavi
Journal:  Abdom Radiol (NY)       Date:  2022-08-11

6.  Comparative analysis of wavelet transform filtering systems for noise reduction in ultrasound images.

Authors:  Dominik Vilimek; Jan Kubicek; Milos Golian; Rene Jaros; Radana Kahankova; Pavla Hanzlikova; Daniel Barvik; Alice Krestanova; Marek Penhaker; Martin Cerny; Ondrej Prokop; Marek Buzga
Journal:  PLoS One       Date:  2022-07-07       Impact factor: 3.752

7.  A review of ultrasound common carotid artery image and video segmentation techniques.

Authors:  Christos P Loizou
Journal:  Med Biol Eng Comput       Date:  2014-10-05       Impact factor: 2.602

8.  Texture Feature Variability in Ultrasound Video of the Atherosclerotic Carotid Plaque.

Authors:  Christos P Loizou; Constantinos S Pattichis; Marios Pantziaris; Efthyvoulos Kyriacou; Andrew Nicolaides
Journal:  IEEE J Transl Eng Health Med       Date:  2017-09-28       Impact factor: 3.316

9.  Blind Source Parameters for Performance Evaluation of Despeckling Filters.

Authors:  Nagashettappa Biradar; M L Dewal; ManojKumar Rohit; Sanjaykumar Gowre; Yogesh Gundge
Journal:  Int J Biomed Imaging       Date:  2016-05-19

10.  Digital Path Approach Despeckle Filter for Ultrasound Imaging and Video.

Authors:  Marek Szczepański; Krystian Radlak
Journal:  J Healthc Eng       Date:  2017-10-08       Impact factor: 2.682

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.