Literature DB >> 24559278

Fast-sequence MRI studies for surveillance imaging in pediatric hydrocephalus.

Daxa M Patel1, R Shane Tubbs, Gigi Pate, James M Johnston, Jeffrey P Blount.   

Abstract

OBJECT: Surveillance imaging of the cerebral ventricles can be valuable in following up children with shunt-treated hydrocephalus. There also, however, has been recent increased awareness and concern over the potential risk associated with imaging-related radiation exposure in children. Magnetic resonance imaging represents an imaging alternative that does not use ionizing radiation; however, its practical utility has been limited due to the near-uniform requirement for sedation or general anesthesia in children. Magnetic resonance imaging without sedation is often futile because of the movement artifact produced by the nonsedated pediatric patient. Some studies have demonstrated the feasibility of using fast-sequence MRI (fsMRI), but the reported experiences are limited. The authors have incorporated fsMRI into their routine shunt surveillance imaging paradigms and report here a 5-year experience with this modality.
METHODS: The authors initially started using fsMRI for routine surveillance in a single clinic in 2008 and have gradually increased their institutional utilization of this modality as experience has accumulated and protocols have been refined. Imaging sequences obtained for each child include an axial T2-weighted half-Fourier acquisition single-shot turbo spin-echo (HASTE), coronal T2-weighted HASTE, and sagittal T2-weighted HASTE images. The authors conducted a retrospective chart and imaging review. They rated each fsMR image according to 5 visibility parameters: 1) ventricle size, 2) ventricle configuration, 3) presence or absence of transependymal flow, 4) presence or absence of motion artifact, and 5) visualization of the ventricular catheter. Each parameter was graded as 1 (present) or 0 (absent). Thus, the maximum value assigned to each scan could be 5 and the minimum value assigned to each scan could be 0. Interrater reliability between pairs of observers was calculated using the Kendall's tau-b and intraclass coefficients.
RESULTS: Two hundred patients underwent fsMRI. No child required sedation. The average duration of examinations was approximately 3.37 minutes, and mean age of the patients was 5.7 years. Clinically useful images were attained in all cases. Overall quality of the fsMRI studies based on the 5 different visibility parameters showed that 169 images (84.5%) included 4 or 5 parameters (score ≥ 4) and had statistically significant excellent quality. The Kendall's tau-b for the overall fsMRI ratings was 0.82 (p = 0.002) and the intraclass coefficient was 0.87 (p < 0.0001).
CONCLUSIONS: In the present cohort of 200 patients, fsMRI studies were shown to have an excellent overall quality and a statistically significant high degree of interrater reliability. Consequently, the authors propose that fsMRI is a sufficiently effective modality that eliminates the need for sedation and the use of ionizing radiation and that it should supplant CT for routine surveillance imaging in hydrocephalic patients.

Entities:  

Mesh:

Year:  2014        PMID: 24559278     DOI: 10.3171/2014.1.PEDS13447

Source DB:  PubMed          Journal:  J Neurosurg Pediatr        ISSN: 1933-0707            Impact factor:   2.375


  17 in total

1.  Variable Refocusing Flip Angle Single-Shot Imaging for Sedation-Free Fast Brain MRI.

Authors:  R Jabarkheel; E Tong; E H Lee; T M Cullen; U Yousaf; A M Loening; V Taviani; M Iv; G A Grant; S J Holdsworth; S S Vasanawala; K W Yeom
Journal:  AJNR Am J Neuroradiol       Date:  2020-06-25       Impact factor: 3.825

2.  Diagnostic Performance of Ultrafast Brain MRI for Evaluation of Abusive Head Trauma.

Authors:  S F Kralik; M Yasrebi; N Supakul; C Lin; L G Netter; R A Hicks; R A Hibbard; L L Ackerman; M L Harris; C Y Ho
Journal:  AJNR Am J Neuroradiol       Date:  2017-02-09       Impact factor: 3.825

Review 3.  Magnetic resonance imaging acquisition techniques intended to decrease movement artefact in paediatric brain imaging: a systematic review.

Authors:  Julie Woodfield; Susan Kealey
Journal:  Pediatr Radiol       Date:  2015-03-28

4.  Implementation of a brain injury screen MRI for infants at risk for abusive head trauma.

Authors:  Rachel P Berger; Andre D Furtado; Lynda L Flom; Janet B Fromkin; Ashok Panigrahy
Journal:  Pediatr Radiol       Date:  2020-01-04

5.  Feasibility of fast brain diffusion MRI to quantify white matter injury in pediatric hydrocephalus.

Authors:  Albert M Isaacs; Joshua S Shimony; Diego M Morales; Leandro Castaneyra-Ruiz; Alexis Hartman; Madison Cook; Christopher D Smyser; Jennifer Strahle; Matthew D Smyth; Yan Yan; James P McAllister; Robert C McKinstry; David D Limbrick
Journal:  J Neurosurg Pediatr       Date:  2019-07-19       Impact factor: 2.375

Review 6.  Management of the Pediatric Neurocritical Care Patient.

Authors:  Christopher M Horvat; Haifa Mtaweh; Michael J Bell
Journal:  Semin Neurol       Date:  2016-12-01       Impact factor: 3.420

Review 7.  Pediatric neuro MRI: tricks to minimize sedation.

Authors:  Matthew J Barkovich; Duan Xu; Rahul S Desikan; Cassandra Williams; A James Barkovich
Journal:  Pediatr Radiol       Date:  2017-04-22

8.  The communication of the radiation risk from CT in relation to its clinical benefit in the era of personalized medicine: part 2: benefits versus risk of CT.

Authors:  Sjirk J Westra
Journal:  Pediatr Radiol       Date:  2014-10-11

9.  Rapid MRI evaluation of acute intracranial hemorrhage in pediatric head trauma.

Authors:  Maura E Ryan; Alok Jaju; Jody D Ciolino; Tord Alden
Journal:  Neuroradiology       Date:  2016-04-12       Impact factor: 2.804

10.  Development of a screening MRI for infants at risk for abusive head trauma.

Authors:  Lynda Flom; Janet Fromkin; Ashok Panigrahy; Elizabeth Tyler-Kabara; Rachel P Berger
Journal:  Pediatr Radiol       Date:  2015-11-20
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.