Analytic comparison between X-ray fluorescence CT and K-edge CT.

Peng Feng, Wenxiang Cong, Biao Wei, Ge Wang.   

Abstract

X-ray fluorescence computed tomography (XFCT) and K-edge computed tomography (CT) are two important modalities to quantify a distribution of gold nanoparticles (GNPs) in a small animal for preclinical studies. It is valuable to determine which modality is more efficient for a given application. In this paper, we report a theoretical analysis in terms of signal-to-noise ratio (SNR) for the two modalities, showing that there is a threshold of GNPs concentration such that XFCT has a better SNR than K-edge CT when GNPs concentration is less than this threshold, vice versa. Numerical tests are performed for XFCT and K-edge CT on two kinds of phantoms with multiple concentration levels and structural features. Experimental results illustrate that XFCT is superior to K-edge CT when contrast concentration is lower than 0.4% which coincides with the theoretical analysis.

Mesh:

Substances:

Year:  2014        PMID: 24557699     DOI: 10.1109/TBME.2013.2294677

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  7 in total

1.  Experimental validation of L-shell x-ray fluorescence computed tomography imaging: phantom study.

Authors:  Magdalena Bazalova-Carter; Moiz Ahmad; Lei Xing; Rebecca Fahrig
Journal:  J Med Imaging (Bellingham)       Date:  2015-10-08

2.  Linearly polarized X-ray fluorescence computed tomography based on a Thomson scattering light source: a Monte Carlo study.

Authors:  Zhijun Chi; Yingchao Du; Wenhui Huang; Chuanxiang Tang
Journal:  J Synchrotron Radiat       Date:  2020-04-06       Impact factor: 2.616

3.  Feasibility study of Compton cameras for x-ray fluorescence computed tomography with humans.

Authors:  Don Vernekohl; Moiz Ahmad; Garry Chinn; Lei Xing
Journal:  Phys Med Biol       Date:  2016-11-15       Impact factor: 3.609

4.  Investigation of transmission computed tomography (CT) image quality and x-ray dose achievable from an experimental dual-mode benchtop x-ray fluorescence CT and transmission CT system.

Authors:  Luzhen Deng; Selcuk Yasar; Md Foiez Ahmed; Sandun Jayarathna; Peng Feng; Biao Wei; Srinivasan Vedantham; Andrew Karellas; Sang Hyun Cho
Journal:  J Xray Sci Technol       Date:  2019       Impact factor: 1.535

5.  Joint Optimization of Collimator and Reconstruction Parameters in X-Ray Fluorescence Computed Tomography Using Analytical Point Spread Function and Model Observer.

Authors:  Hsin Wu Tseng; Srinivasan Vedantham; Sang Hyun Cho; Andrew Karellas
Journal:  IEEE Trans Biomed Eng       Date:  2019-12-30       Impact factor: 4.538

6.  Monte Carlo Simulation for Polychromatic X-Ray Fluorescence Computed Tomography with Sheet-Beam Geometry.

Authors:  Shanghai Jiang; Peng He; Luzhen Deng; Mianyi Chen; Biao Wei
Journal:  Int J Biomed Imaging       Date:  2017-05-08

7.  A Geant4-based Monte Carlo study of a benchtop multi-pinhole X-ray fluorescence computed tomography imaging.

Authors:  Luzhen Deng; Biao Wei; Peng He; Yi Zhang; Peng Feng
Journal:  Int J Nanomedicine       Date:  2018-11-08