Rates of revision and device failure in cochlear implant surgery: a 30-year experience.

Jeffrey T Wang1, Allen Y Wang, Colleen Psarros, Melville Da Cruz.   

Abstract

OBJECTIVES/HYPOTHESIS: To characterize revision cochlear implant surgery and quantify rates of revision and device failure. STUDY
DESIGN: Retrospective review of 235 cases of revision cochlear implant surgery performed at the Sydney Cochlear Implant Center over a period of 30 years, between January 1982 and June 2011.
METHODS: Patient demographics and characteristics of revision surgery were retrospectively extracted from a centralized database. Analyses of overall and cumulative rates were performed.
RESULTS: During the study period, 2,827 primary cochlear implantations were performed in 2,311 patients, with 201 primary implants in 191 patients of this cohort (109 children and 82 adults) undergoing 235 revision surgeries. The most common indication for revision surgery was device failure (57.8%), followed by migration/extrusion (23.4%), infection/wound complication (17.0%), and poor outcome/secondary pathology (6.4%). The majority of revision surgeries were reimplantations. Overall revision and device failure rates were 8.3% and 4.8%, respectively. The cumulative revision rate for primary implants at all ages increased linearly by 1% per year. The cumulative revision rate was significantly higher in children, and decreased with more recently performed implantations and with newer generations of implants.
CONCLUSIONS: The cumulative revision rate for primary implants suggests an ongoing linear relationship between the time of postprimary implantation and the need for revision surgery. We have formed an evidence base that characterizes the nature and frequency of revision surgery in a high-volume setting, allowing clinicians to effectively counsel prospective patients and clinics to understand the burden of revision surgery and device failure.
© 2014 The American Laryngological, Rhinological and Otological Society, Inc.

Entities:  

Keywords:  Cochlear implant; device failure; device failure rate; explantation; hard failure; reimplantation; revision rate; revision surgery; soft failure

Mesh:

Year:  2014        PMID: 24550135     DOI: 10.1002/lary.24649

Source DB:  PubMed          Journal:  Laryngoscope        ISSN: 0023-852X            Impact factor:   3.325


  22 in total

1.  Cochlear Implant Reliability: On the Reporting of Rates of Revision Surgery.

Authors:  Graham O'Neill; Neil S Tolley
Journal:  Indian J Otolaryngol Head Neck Surg       Date:  2020-04-01

2.  Surgical findings and auditory performance after cochlear implant revision surgery.

Authors:  R Manrique-Huarte; A Huarte; M J Manrique
Journal:  Eur Arch Otorhinolaryngol       Date:  2015-03-27       Impact factor: 2.503

Review 3.  Treatment of late sequelae after radiotherapy for head and neck cancer.

Authors:  Primož Strojan; Katherine A Hutcheson; Avraham Eisbruch; Jonathan J Beitler; Johannes A Langendijk; Anne W M Lee; June Corry; William M Mendenhall; Robert Smee; Alessandra Rinaldo; Alfio Ferlito
Journal:  Cancer Treat Rev       Date:  2017-07-18       Impact factor: 12.111

4.  Electrode migration after cochlear implant surgery: more common than expected?

Authors:  Aarno Dietz; Minna Wennström; Antti Lehtimäki; Heikki Löppönen; Hannu Valtonen
Journal:  Eur Arch Otorhinolaryngol       Date:  2015-07-12       Impact factor: 2.503

5.  HiRes Ultra Series Recall: Failure Rates and Revision Speech Recognition Outcomes.

Authors:  Nathan R Lindquist; Nathan D Cass; Ankita Patro; Elizabeth L Perkins; René H Gifford; David S Haynes; Jourdan T Holder
Journal:  Otol Neurotol       Date:  2022-08-01       Impact factor: 2.619

6.  A retrospective review of cochlear implant revision surgery: a 24-year experience in China.

Authors:  Jingyuan Chen; Biao Chen; Ying Shi; Yongxin Li
Journal:  Eur Arch Otorhinolaryngol       Date:  2021-04-03       Impact factor: 2.503

7.  Hearing Preservation After Cochlear Reimplantation Using Electrocochleography: A Case Report.

Authors:  Amit Walia; Matthew A Shew; Amanda J Ortmann; Craig A Buchman; Jacques A Herzog
Journal:  Laryngoscope       Date:  2021-07-03       Impact factor: 2.970

8.  Comparisons of Auditory Performance and Speech Intelligibility after Cochlear Implant Reimplantation in Mandarin-Speaking Users.

Authors:  Chung-Feng Hwang; Hui-Chen Ko; Yung-Ting Tsou; Kai-Chieh Chan; Hsuan-Yeh Fang; Che-Ming Wu
Journal:  Biomed Res Int       Date:  2016-06-16       Impact factor: 3.411

9.  Implantable Devices for Single-Sided Deafness and Conductive or Mixed Hearing Loss: A Health Technology Assessment.

Authors: 
Journal:  Ont Health Technol Assess Ser       Date:  2020-03-06

Review 10.  Bilateral Cochlear Implantation: A Health Technology Assessment.

Authors: 
Journal:  Ont Health Technol Assess Ser       Date:  2018-10-24
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.