Literature DB >> 24548900

Interstitial insulin kinetic parameters for a 2-compartment insulin model with saturable clearance.

Christopher G Pretty1, Aaron Le Compte2, Sophie Penning3, Liam Fisk4, Geoffrey M Shaw5, Thomas Desaive6, J Geoffrey Chase7.   

Abstract

Glucose-insulin system models are commonly used for identifying insulin sensitivity. With physiological, 2-compartment insulin kinetics models, accurate kinetic parameter values are required for reliable estimates of insulin sensitivity. This study uses data from 6 published microdialysis studies to determine the most appropriate parameter values for the transcapillary diffusion rate (n(I)) and cellular insulin clearance rate (n(C)). The 6 studies (12 data sets) used microdialysis techniques to simultaneously obtain interstitial and plasma insulin concentrations. The reported plasma insulin concentrations were used as input and interstitial insulin concentrations were simulated with the interstitial insulin kinetics sub-model. These simulated results were then compared to the reported interstitial measurements and the most appropriate set of parameter values was determined across the 12 data sets by combining the results. Interstitial insulin kinetic parameters values n(I)=n(C)=0.0060 min⁻¹ were shown to be the most appropriate. These parameter values are associated with an effective, interstitial insulin half-life, t(½)=58 min, within the range of 25-130 min reported by others.
Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Keywords:  Biomedical system modelling; Control of physiological and clinical variables; Simulation and visualisation

Mesh:

Substances:

Year:  2014        PMID: 24548900     DOI: 10.1016/j.cmpb.2014.01.011

Source DB:  PubMed          Journal:  Comput Methods Programs Biomed        ISSN: 0169-2607            Impact factor:   5.428


  2 in total

1.  Human insulin dynamics in women: a physiologically based model.

Authors:  Michael Weiss; Andrea Tura; Alexandra Kautzky-Willer; Giovanni Pacini; David Z D'Argenio
Journal:  Am J Physiol Regul Integr Comp Physiol       Date:  2015-11-25       Impact factor: 3.619

2.  The in vitro Analysis of Quality of Ovarian Follicle Culture Systems Using Time-Lapse Microscopy and Quantitative Real-Time PCR.

Authors:  Maxim Alexeevich Filatov; Denis Alexandrovich Nikishin; Yulia Vladimirovna Khramova; Maria L'vovna Semenova
Journal:  J Reprod Infertil       Date:  2020 Apr-Jun
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.