Comparison of two methods of digital imaging technology for small diameter K-file length determination.

Ehsani Maryam1, Abesi Farida2, Akbarzade Farhad3, Khafri Soraya4.   

Abstract

OBJECTIVES: Obtaining the proper working length in endodontic treatment is essential. The aim of this study was to compare the working length (WL) assessment of small diameter K-files using the two different digital imaging methods.
METHODOLOGY: The samples for this in-vitro experimental study consisted of 40 extracted single-rooted premolars. After access cavity preparation, the ISO files no. 6, 8, and 10 stainless steel K-files were inserted in the canals in the three different lengths to evaluate the results in a blinded manner: At the level of apical foramen(actual)1 mm short of apical foramen2 mm short of apical foramen A digital caliper was used to measure the length of the files which was considered as the Gold Standard. Five observers (two oral and maxillofacial radiologists and three endodontists) observed the digital radiographs which were obtained using PSP and CCD digital imaging sensors. The collected data were analyzed by SPSS 17 and Repeated Measures Paired T-test.
RESULTS: In WL assessment of small diameter K-files, a significant statistical relationship was seen among the observers of two digital imaging techniques (P<0.001). However, no significant difference was observed between the two digital techniques in WL assessment of small diameter K-files (P<0.05).
CONCLUSION: PSP and CCD digital imaging techniques were similar in WL assessment of canals using no. 6, 8, and 10 K-files.

Entities:  

Keywords:  Digital imaging; K-file; Working length

Year:  2013        PMID: 24533021      PMCID: PMC3921057          DOI: 10.12816/0006056

Source DB:  PubMed          Journal:  Int J Health Sci (Qassim)        ISSN: 1658-3639


  10 in total

1.  Canal length evaluation of curved canals by direct digital or conventional radiography.

Authors:  Ali Mentes; Nimet Gencoglu
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2002-01

2.  A comparison of phosphor-plate digital images with conventional radiographs for the perceived clarity of fine endodontic files and periapical lesions.

Authors:  Lara T Friedlander; Robert M Love; Nicholas P Chandler
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2002-03

3.  Clarity and diagnostic quality of digitized conventional intraoral radiographs.

Authors:  R Goga; N P Chandler; R M Love
Journal:  Dentomaxillofac Radiol       Date:  2004-03       Impact factor: 2.419

4.  The use of high-resolution digital imaging technology for small diameter K-file length determination in endodontics.

Authors:  Bart Vandenberghe; Marius Bud; Asti Sutanto; Reinhilde Jacobs
Journal:  Clin Oral Investig       Date:  2009-05-19       Impact factor: 3.573

5.  A comparison of digitally scanned radiographs with conventional film for the detection of small endodontic instruments.

Authors:  K N Fuge; A M Stuck; R M Love
Journal:  Int Endod J       Date:  1998-03       Impact factor: 5.264

6.  A Comparison of intra-oral digital imaging modalities: Charged Couple Device versus Storage Phosphor Plate.

Authors:  A Anas; Jm Asaad; Ka Tarboush
Journal:  Int J Health Sci (Qassim)       Date:  2010-11

7.  Efficacy of several digital radiographic imaging systems for laboratory determination of endodontic file length.

Authors:  M L Oliveira; G M B Ambrosano; S M Almeida; F Haiter-Neto; G M Tosoni
Journal:  Int Endod J       Date:  2011-01-28       Impact factor: 5.264

8.  Endodontic working length assessment. Comparison of storage phosphor digital imaging and radiographic film.

Authors:  R A Cederberg; E Tidwell; N L Frederiksen; B W Benson
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  1998-03

9.  Radiographic endodontic working length estimation: comparison of three digital image receptors.

Authors:  Anas Athar; Christos Angelopoulos; Jerald O Katz; Karen B Williams; Paulette Spencer
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2008-08-20

10.  Direct digital radiography versus conventional radiography - assessment of visibility of file length placed in the root canal: An in vitro study.

Authors:  Vaiyapuri Ravi; Priyadarshini Lipee; Canagapalli Venkat Nakabushan Rao; Lakshminarayanan Lakshmikanthan
Journal:  J Pharm Bioallied Sci       Date:  2012-08
  10 in total
  1 in total

1.  In vitro Evaluation of the Accuracy of the Root Zx in the Presence of Naocl 2.5% and Chlorhexidine 0.2.

Authors:  Marjan Bolbolian; Siamak Golchin; Seyedmatin Faegh
Journal:  J Clin Exp Dent       Date:  2018-11-01
  1 in total