Literature DB >> 24532033

CT-based attenuation correction in Tl-201 myocardial perfusion scintigraphy is less effective than non-corrected SPECT for risk stratification.

Christos A Savvopoulos1, Trifon Spyridonidis, Nikolaos Papandrianos, Pavlos J Vassilakos, Dimitrios Alexopoulos, Dimitris J Apostolopoulos.   

Abstract

BACKGROUND: Previous studies advocate the use of attenuation correction in myocardial perfusion scintigraphy (MPS) for patient risk stratification.
METHODS: Six-hundred and thirty-seven unselected patients underwent Tl-201 MPS by a hybrid SPECT/CT system. Attenuation-corrected (AC) and non-corrected (NAC) images were interpreted blindly and summed stress scores (SSS) were calculated. Study endpoints were all-cause mortality and the composites of death/non-fatal acute myocardial infarction (AMI) and death/AMI/late revascularization.
RESULTS: During a follow-up of 42.3 ± 12.8 months 24 deaths, 13 AMIs and 28 revascularizations were recorded. SSS groups formed according to event rate distribution across SSS values were: 0-4, 5-13, >13 for NAC and 0-2, 3-9, >9 for AC. Kaplan-Meier functions were statistically significant between NAC SSS groups for all study endpoints. AC discriminated only between SSS 0-2 and >9 for death/AMI and between 0-2 and 3-9 for death/AMI/revascularization. In the univariate Cox regression abnormal NAC (SSS > 4) was accompanied with much higher hazards ratios than abnormal AC (SSS > 2). In the multivariate model abnormal AC yielded no significance for either endpoint whereas abnormal NAC proved independent from other covariates for the composite endpoints.
CONCLUSION: Our results challenge the effectiveness of CT-based AC for risk stratification of patients referred for MPS.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24532033     DOI: 10.1007/s12350-014-9867-7

Source DB:  PubMed          Journal:  J Nucl Cardiol        ISSN: 1071-3581            Impact factor:   5.952


  36 in total

Review 1.  Single-photon emission computed tomography/computed tomography: basic instrumentation and innovations.

Authors:  Michael K O'Connor; Brad J Kemp
Journal:  Semin Nucl Med       Date:  2006-10       Impact factor: 4.446

2.  Attenuation-corrected thallium-201 single-photon emission tomography using a gadolinium-153 moving line source: clinical value and the impact of attenuation correction on the extent and severity of perfusion abnormalities.

Authors:  H J Gallowitsch; J Sykora; P Mikosch; E Kresnik; O Unterweger; M Molnar; G Grimm; P Lind
Journal:  Eur J Nucl Med       Date:  1998-03

3.  Clinical validation of SPECT attenuation correction using x-ray computed tomography-derived attenuation maps: multicenter clinical trial with angiographic correlation.

Authors:  Yasmin Masood; Yi-Hwa Liu; Gordon Depuey; Raymond Taillefer; Luis I Araujo; Steven Allen; Dominique Delbeke; Frank Anstett; Aharon Peretz; Mary-Jo Zito; Vera Tsatkin; Frans J Th Wackers
Journal:  J Nucl Cardiol       Date:  2005 Nov-Dec       Impact factor: 5.952

4.  Attenuation correction for myocardial perfusion SPECT imaging: still a controversial issue.

Authors:  Alberto Cuocolo
Journal:  Eur J Nucl Med Mol Imaging       Date:  2011-08-27       Impact factor: 9.236

5.  Effects of misalignment between transmission and emission scans on attenuation-corrected cardiac SPECT.

Authors:  I Matsunari; G Böning; S I Ziegler; I Kosa; S G Nekolla; E P Ficaro; M Schwaiger
Journal:  J Nucl Med       Date:  1998-03       Impact factor: 10.057

6.  Limited incremental diagnostic values of attenuation-noncorrected gating and ungated attenuation correction to rest/stress myocardial perfusion SPECT in patients with an intermediate likelihood of coronary artery disease.

Authors:  D S Lee; Y So; G J Cheon; K M Kim; M M Lee; J K Chung; M C Lee
Journal:  J Nucl Med       Date:  2000-05       Impact factor: 10.057

7.  Simultaneous transmission-emission thallium-201 cardiac SPECT: effect of attenuation correction on myocardial tracer distribution.

Authors:  E P Ficaro; J A Fessler; R J Ackermann; W L Rogers; J R Corbett; M Schwaiger
Journal:  J Nucl Med       Date:  1995-06       Impact factor: 10.057

8.  Incremental prognostic value of myocardial perfusion single photon emission computed tomography for the prediction of cardiac death: differential stratification for risk of cardiac death and myocardial infarction.

Authors:  R Hachamovitch; D S Berman; L J Shaw; H Kiat; I Cohen; J A Cabico; J Friedman; G A Diamond
Journal:  Circulation       Date:  1998-02-17       Impact factor: 29.690

9.  Evaluation of an attenuation correction method for thallium-201 myocardial perfusion tomographic imaging of patients with low likelihood of coronary artery disease.

Authors:  P Chouraqui; S Livschitz; T Sharir; N Wainer; M Wilk; I Moalem; J Baron
Journal:  J Nucl Cardiol       Date:  1998 Jul-Aug       Impact factor: 5.952

10.  Clinical value of stress-only Tc-99m SPECT imaging: importance of attenuation correction.

Authors:  Shishir Mathur; Gary V Heller; Timothy M Bateman; Richard Ruffin; Arshad Yekta; Deborah Katten; Nitya Alluri; Alan W Ahlberg
Journal:  J Nucl Cardiol       Date:  2012-11-28       Impact factor: 5.952

View more
  2 in total

1.  Deep Learning-Based Automated Diagnosis for Coronary Artery Disease Using SPECT-MPI Images.

Authors:  Nikolaos I Papandrianos; Anna Feleki; Elpiniki I Papageorgiou; Chiara Martini
Journal:  J Clin Med       Date:  2022-07-05       Impact factor: 4.964

2.  Long-term prognostic value of computed tomography-based attenuation correction on thallium-201 myocardial perfusion imaging: A cohort study.

Authors:  Jei-Yie Huang; Ruoh-Fang Yen; Chun-Kai Huang; Chia-Ju Liu; Mei-Fang Cheng; Kuo-Liong Chien; Yen-Wen Wu
Journal:  PLoS One       Date:  2021-10-26       Impact factor: 3.240

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.