Literature DB >> 24522150

Fit of 4-unit FDPs made of zirconia and CoCr-alloy after chairside and labside digitalization--a laboratory study.

Christine Keul1, Bogna Stawarczyk2, Kurt-Jürgen Erdelt2, Florian Beuer2, Daniel Edelhoff2, Jan-Frederik Güth2.   

Abstract

OBJECTIVES: To analyse the marginal fit of 4-unit fixed dental prostheses (FDPs) and the accuracy of three-dimensional cast-datasets using both approaches to Computer Aided Design (CAD)/Computer Aided Manufacturing (CAM): direct and indirect digitalization.
METHODS: A titanium model of a 4-unit FDP was digitized by an intraoral scanning device (iTero, Align Technology, Carlstadt, US; DD, n=12). Additionally 12 conventional impressions were taken and referring master casts were digitized by a laboratory scanner (CS2, Straumann, Basel, Switzerland; ID, n=12). Frameworks were fabricated (CARES CADCAM GmbH, Straumann, Markkleeberg, Germany) from base metal alloy (coron, Straumann; DD-C: n=12; ID-C: n=12) and zirconia (zerion, Straumann; DD-Z: n=12; ID-Z: n=12) from the same datasets. The marginal fit of the resulting frameworks and the accuracy of the underlying datasets from DD and ID were evaluated. Data were analyzed by unpaired two sample Student's t-test with Levene-test (p<0.05).
RESULTS: Frameworks from group DD-C showed significantly better marginal fit than ID-C (DD-C: 56.90±27.37 μm, ID-C: 90.64±90.81 μm). For zirconia frameworks no differences between both digitalization methods (DD-Z: 127.23±66.87 μm, ID-Z: 141.08±193.17 μm) could be observed. Base metal alloy frameworks exhibited significantly better marginal fit than zirconia frameworks (DD: p<0.001; ID: p=0.022). Regarding the accuracy group DD showed significantly higher "trueness" than ID. SIGNIFICANCE: Direct and indirect digitalization lead to clinically acceptable marginal fit of 4-unit FDPs from base metal alloy and zirconia. Higher accuracy of datasets from DD leads to better marginal fit of frameworks from base metal alloy but not for ones from zirconia.
Copyright © 2014 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Accuracy; Digital impression; Intraoral scanner; Marginal fit; Replica-technique

Mesh:

Substances:

Year:  2014        PMID: 24522150     DOI: 10.1016/j.dental.2014.01.006

Source DB:  PubMed          Journal:  Dent Mater        ISSN: 0109-5641            Impact factor:   5.304


  27 in total

1.  In vivo precision of conventional and digital methods for obtaining quadrant dental impressions.

Authors:  Andreas Ender; Moritz Zimmermann; Thomas Attin; Albert Mehl
Journal:  Clin Oral Investig       Date:  2015-11-07       Impact factor: 3.573

2.  Influence of conventional and digital intraoral impressions on the fit of CAD/CAM-fabricated all-ceramic crowns.

Authors:  S Berrendero; M P Salido; A Valverde; A Ferreiroa; G Pradíes
Journal:  Clin Oral Investig       Date:  2016-01-23       Impact factor: 3.573

3.  A new method for the evaluation of the accuracy of full-arch digital impressions in vitro.

Authors:  Jan-Frederik Güth; Daniel Edelhoff; Josef Schweiger; Christine Keul
Journal:  Clin Oral Investig       Date:  2015-10-10       Impact factor: 3.573

4.  Accuracy of full-arch digital impressions: an in vitro and in vivo comparison.

Authors:  Christine Keul; Jan-Frederik Güth
Journal:  Clin Oral Investig       Date:  2019-05-27       Impact factor: 3.573

5.  Can lithium disilicate ceramic crowns be fabricated on the basis of CBCT data?

Authors:  Ana Elisa Colle Kauling; Christine Keul; Kurt Erdelt; Jan Kühnisch; Jan-Frederik Güth
Journal:  Clin Oral Investig       Date:  2019-02-06       Impact factor: 3.573

6.  Digital implant planning and guided implant surgery - workflow and reliability.

Authors:  O Schubert; J Schweiger; M Stimmelmayr; E Nold; J-F Güth
Journal:  Br Dent J       Date:  2019-01-25       Impact factor: 1.626

7.  Accuracy of five intraoral scanners compared to indirect digitalization.

Authors:  Jan-Frederik Güth; Cornelius Runkel; Florian Beuer; Michael Stimmelmayr; Daniel Edelhoff; Christine Keul
Journal:  Clin Oral Investig       Date:  2016-07-12       Impact factor: 3.573

8.  Fitting accuracy of zirconia single crowns produced via digital and conventional impressions-a clinical comparative study.

Authors:  Matthias Rödiger; Arthur Heinitz; Ralf Bürgers; Sven Rinke
Journal:  Clin Oral Investig       Date:  2016-07-28       Impact factor: 3.573

9.  Accuracy of multi-unit implant impression: traditional techniques versus a digital procedure.

Authors:  Maria Menini; Paolo Setti; Francesco Pera; Paolo Pera; Paolo Pesce
Journal:  Clin Oral Investig       Date:  2017-09-30       Impact factor: 3.573

10.  Evaluation of fit and efficiency of CAD/CAM fabricated all-ceramic restorations based on direct and indirect digitalization: a double-blinded, randomized clinical trial.

Authors:  Danush Ahrberg; Hans Christoph Lauer; Martin Ahrberg; Paul Weigl
Journal:  Clin Oral Investig       Date:  2015-06-14       Impact factor: 3.573

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.