| Literature DB >> 24520726 |
Xiaoqing Lin1, Yuqi Jin2, Hailong Wu3, Tong Chen2, Xiaodong Li2, Shengyong Lu2, Xuguang Jiang2, Jianhua Yan2.
Abstract
A 100 Nm3/hr capacity pilot scale dual bag filter (DBF) system was tested on the flue gas from an actual hazardous waste incinerator (HWI), the removal efficiency of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs) and polychlorinated biphenyls (PCBs) was also studied. The first filter collected most of the fly ash and associated chlorinated organic; then activated carbon (AC) was injected and used to collect phase chlorinated organic from the gas. Concentrations of PCDD/Fs and PCBs after the DBF system were 0.07 and 0.01 ng TEQ/Nm3, respectively, which were both far below the national emission standard. Comparing with the original single bag filter system, the PCDD/Fs concentration dropped a lot from 0.36 to 0.07 ng TEQ/Nm3. Increasing AC feeding rate enhanced their collection efficiency, yet reduced the AC utilization efficiency, and it still needs further study to select an appropriate feeding rate in the system. These results will be useful for industrial application and assist in controlling emissions of PCDD/Fs and other persistent organic pollutions from stationary sources in China.Entities:
Mesh:
Substances:
Year: 2013 PMID: 24520726 DOI: 10.1016/s1001-0742(12)60292-7
Source DB: PubMed Journal: J Environ Sci (China) ISSN: 1001-0742 Impact factor: 5.565