Literature DB >> 24512801

A modified multi-echo AFI for simultaneous B1(+) magnitude and phase mapping.

Narae Choi1, Joonsung Lee1, Min-Oh Kim1, Jaewook Shin1, Dong-Hyun Kim2.   

Abstract

To simultaneously acquire the B1(+) magnitude and B1(+) phase, a modified multi-echo actual flip-angle imaging (AFI) sequence is proposed. A multi-echo gradient echo sequence was integrated into every even TR of AFI to measure both magnitude and phase of B1(+). In addition, to increase the signal-to-noise ratio of the B1(+) phase, a double-angle multi-echo AFI sequence, in which the flip-angle of the RF pulses is α at the odd TR and 2α at the even TR is proposed. Images were simulated to evaluate the performance of this method under various imaging and physical parameters. The performance was compared to the spin echo based B1(+) mapping method in phantom and in vivo studies. In the simulation, the estimation error decreased as TR1/T1 decreased and TR2/TR1 increased. For double-angle AFI, flip-angle ranges that could estimate B1(+) magnitude and phase better than the original AFI were identified. Using the proposed method, B1(+) phase estimation was similar to spin echo phase. In the phantom study, correlation coefficient between the estimated B1(+) phases using the spin echo and the proposed method was 0.9998. The results show that the B1(+) magnitude and B1(+) phase can be simultaneously acquired and accurately estimated using the proposed double-angle AFI method.
Copyright © 2014 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Actual flip-angle imaging; B(1) complex mapping; B(1) mapping; B(1) phase; Double-angle AFI (DA AFI); Multi-echo AFI

Mesh:

Year:  2014        PMID: 24512801     DOI: 10.1016/j.mri.2013.12.005

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  6 in total

1.  Modification of population based arterial input function to incorporate individual variation.

Authors:  Harrison Kim
Journal:  Magn Reson Imaging       Date:  2017-09-27       Impact factor: 2.546

2.  Portable perfusion phantom for quantitative DCE-MRI of the abdomen.

Authors:  Harrison Kim; Mina Mousa; Patrick Schexnailder; Robert Hergenrother; Mark Bolding; Bernard Ntsikoussalabongui; Vinoy Thomas; Desiree E Morgan
Journal:  Med Phys       Date:  2017-08-12       Impact factor: 4.071

3.  Variability in Quantitative DCE-MRI: Sources and Solutions.

Authors:  Harrison Kim
Journal:  J Nat Sci       Date:  2018

4.  Disposable point-of-care portable perfusion phantom for quantitative DCE-MRI.

Authors:  Martin D Holland; Andres Morales; Sean Simmons; Brandon Smith; Samuel R Misko; Xiaoyu Jiang; David A Hormuth; Chase Christenson; Roy P Koomullil; Desiree E Morgan; Yufeng Li; Junzhong Xu; Thomas E Yankeelov; Harrison Kim
Journal:  Med Phys       Date:  2021-12-10       Impact factor: 4.506

5.  Complex B1 + mapping with Carr-Purcell spin echoes and its application to electrical properties tomography.

Authors:  Santhosh Iyyakkunnel; Matthias Weigel; Carl Ganter; Oliver Bieri
Journal:  Magn Reson Med       Date:  2021-11-09       Impact factor: 3.737

6.  Accurate Therapeutic Response Assessment of Pancreatic Ductal Adenocarcinoma Using Quantitative Dynamic Contrast-Enhanced Magnetic Resonance Imaging With a Point-of-Care Perfusion Phantom: A Pilot Study.

Authors:  Harrison Kim; Desiree E Morgan; Patrick Schexnailder; Rudolph M Navari; Grant R Williams; J Bart Rose; Yufeng Li; Ravikumar Paluri
Journal:  Invest Radiol       Date:  2019-01       Impact factor: 6.016

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.