Literature DB >> 24512649

Changes in hematology measurements in healthy and diseased dog blood stored at room temperature for 24 and 48 hours using the XT-2000iV analyzer.

Nathalie H Bourgès-Abella1, Anne Geffré, Pierre L Deshuillers, Jean-Pierre D Braun, Catherine Trumel.   

Abstract

BACKGROUND: Changes in canine hematology measurements may occur when analyses are delayed due to shipment of specimens to a laboratory.
OBJECTIVE: The purpose of this study was to report changes in hematologic variables in healthy and diseased canine blood measured with a Sysmex XT-2000iV during storage at room temperature for 24 and 48 hours.
METHODS: EDTA-K3 blood samples from 42 healthy and diseased dogs were measured on a Sysmex XT-2000iV analyzer within one hour of sampling, and after storage for 24 and 48 hours at room temperature in the dark.
RESULTS: Storage caused little or no change in RBC count, HGB concentration and MCH, while there was a moderate increase in HCT, MCV and reticulocytes count, and a moderate decrease in MCHC. Decreased platelet counts by impedance (PLT-I) and optical (PLT-O) measurements were associated with increased mean platelet volume (MPV), platelet-large cell ratio (P-LCR) and platelet distribution width (PDW), including a right shift in the platelet histogram and a dispersion of the platelet dot plot on the scattergram. The total and differential WBC count remained stable except for decreased monocyte counts. In the scatterplots, monocytes shifted into the lymphocyte population after 24 hours, and neutrophil population shifted to the right appearing in the eosinophil gate at 48 hours of storage. The disease status had only a small effect on storage-induced changes, and observed changes had no consequences for clinical decisions.
CONCLUSIONS: Blood storage at room temperature was accompanied by moderate variations in some hematologic variables, awareness of which helps in avoiding misinterpretations.
© 2014 American Society for Veterinary Clinical Pathology and European Society for Veterinary Clinical Pathology.

Entities:  

Keywords:  Autolysis; XT-2000iV; blood storage; canine; hematology

Mesh:

Year:  2014        PMID: 24512649     DOI: 10.1111/vcp.12119

Source DB:  PubMed          Journal:  Vet Clin Pathol        ISSN: 0275-6382            Impact factor:   1.180


  5 in total

1.  Neutrophil to lymphocyte ratio in allergic rhinitis.

Authors:  Viroj Wiwanitkit
Journal:  Eur Arch Otorhinolaryngol       Date:  2016-01-13       Impact factor: 2.503

2.  Changes of hematological references depends on storage period and temperature conditions in rats and dogs.

Authors:  Jung-Min Lee; Jin Seok Kang
Journal:  Lab Anim Res       Date:  2016-12-23

3.  Effects of pre-analytical handling on selected canine hematological parameters evaluated by automatic analyzer.

Authors:  Labrini Vasileiou Athanasiou; Zoe Polizopoulou; Maria Rafaela Kalafati; George Ntararas; Vasileios Kontos
Journal:  Vet Res Forum       Date:  2016-12-15       Impact factor: 1.054

4.  Evaluation of mouse red blood cell and platelet counting with an automated hematology analyzer.

Authors:  Teruko Fukuda; Eri Asou; Kimiko Nogi; Kazuo Goto
Journal:  J Vet Med Sci       Date:  2017-08-27       Impact factor: 1.267

5.  Evaluation of the scil vCell 5, a novel laser- and impedance-based point-of-care hematology analyzer, for use in dogs and cats.

Authors:  Kim-Lina Charlotte Zelmer; Natali Bauer; Andreas Moritz
Journal:  J Vet Diagn Invest       Date:  2022-03-24       Impact factor: 1.279

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.