Literature DB >> 24510458

Assessment of spleen stiffness using acoustic radiation force impulse imaging (ARFI): definition of examination standards and impact of breathing maneuvers.

T Karlas1, F Lindner1, M Tröltzsch2, V Keim2.   

Abstract

PURPOSE: Spleen elastography is a promising method for the characterization of portal hypertension in cirrhotic individuals. However, standardized examination procedures for spleen stiffness measurement have not been defined yet. We analyzed the distribution characteristics of spleen shear-wave velocity (ARFI) and assessed the influence of the respiratory position on spleen stiffness measured by ARFI.
MATERIALS AND METHODS: 25 healthy probands and 25 patients with Child A liver cirrhosis were prospectively characterized with conventional ultrasound, transient elastography, liver ARFI, and underwent spleen ARFI in two respiratory positions: breath hold after expiration (exp) and deep inspiration (insp). For each position 20 single measurements were performed. The distribution of spleen ARFI values was analyzed for normality and the appropriate number of measurements for spleen stiffness estimation was investigated.
RESULTS: Spleen ARFI results were normally distributed in > 95 % of cases. Performing 20 instead of 10 single measurements resulted in < 5 % deviation from the mean value after 20 measurements in the majority of cases. Cirrhotic patients had a higher spleen stiffness compared to healthy probands (exp: 3.25 ± 0.58 vs. 2.46 ± 0.35 m/s; p < 0.001). Deep inspiration caused an overall increase in spleen stiffness in both groups: probands 2.46 ± 0.35 m/s (exp) vs. 2.66 ± 0.36 m/s (insp), p = 0.01; cirrhotics 3.25 ± 0.58 m/s (exp) vs. 3.46 ± 0.38 m/s (insp), p = 0.03. However, cases with high spleen stiffness values (exp) show decreasing ARFI values in deep inspiration.
CONCLUSION: ARFI values of the spleen are normally distributed and the mean of 10 valid measurements can be used as a representative value. Deep inspiration significantly modulates spleen stiffness. Therefore, the respiratory position needs careful standardization. © Georg Thieme Verlag KG Stuttgart · New York.

Entities:  

Mesh:

Year:  2014        PMID: 24510458     DOI: 10.1055/s-0033-1356230

Source DB:  PubMed          Journal:  Ultraschall Med        ISSN: 0172-4614            Impact factor:   6.548


  8 in total

1.  The relationship of spleen stiffness value measured by shear wave elastography with age, gender, and spleen size in healthy volunteers.

Authors:  Eda Albayrak; Sadık Server
Journal:  J Med Ultrason (2001)       Date:  2019-01-28       Impact factor: 1.314

2.  Spleen elastography in patients with Systemic sclerosis.

Authors:  R Karalilova; K Doykova; Z Batalov; D Doykov; A Batalov
Journal:  Rheumatol Int       Date:  2021-01-25       Impact factor: 2.631

3.  Role of Spleen Stiffness Measurement by 2D-Shear Wave Elastography in Ruling Out the Presence of High-Risk Varices in Cirrhotic Patients.

Authors:  Dimitrios S Karagiannakis; Theodoros Voulgaris; Evgenia Koureta; Elissavet Chloupi; George V Papatheodoridis; John Vlachogiannakos
Journal:  Dig Dis Sci       Date:  2019-04-15       Impact factor: 3.199

4.  Spleen stiffness measurements by acoustic radiation force impulse imaging after living donor liver transplantation in children: a potential quantitative index for venous complications.

Authors:  Hirofumi Tomita; Yasushi Fuchimoto; Kiyoshi Ohkuma; Ken Hoshino; Akihiro Fujino; Mototoshi Kato; Takumi Fujimura; Hideo Ishihama; Nobuhiro Takahashi; Yutaka Tanami; Seishi Nakatsuka; Hirotoshi Ebinuma; Hidetsugu Saito; Masahiro Shinoda; Yuko Kitagawa; Tatsuo Kuroda
Journal:  Pediatr Radiol       Date:  2014-12-12

5.  Shear wave elastography of the spleen using elastography point quantification: stiffness values in healthy children.

Authors:  Anmol Bhatia; Harsimran Bhatia; Akshay Kumar Saxena; Sadhna B Lal; Kushaljit Singh Sodhi
Journal:  Abdom Radiol (NY)       Date:  2022-04-18

Review 6.  Clinical applications of spleen ultrasound elastography - a review.

Authors:  Rafał Mazur; Milena Celmer; Jurand Silicki; Daniel Hołownia; Patryk Pozowski; Krzysztof Międzybrodzki
Journal:  J Ultrason       Date:  2018-03-30

7.  Can Location of Stiffness Measurement Impact Spleen 2-Dimensional Shear Wave Elastography Measurement?

Authors:  Jinzhen Song; Jiawu Li; Yan Luo; Qiang Lu
Journal:  Ultrasound Q       Date:  2022-06-01       Impact factor: 1.462

8.  Comparison of point and two-dimensional shear wave elastography of the spleen in healthy subjects.

Authors:  Friederike Nowotny; Julian Schmidberger; Patrycja Schlingeloff; Andreas Binzberger; Wolfgang Kratzer
Journal:  World J Radiol       Date:  2021-05-28