Use of tightrope fixation in ankle syndesmotic injuries.

Julian Maempel1, Anthony Ward, Tim Chesser, Michael Kelly.   

Abstract

OBJECTIVE: Conventional fixation of syndesmotic injuries with screws remains problematic. A novel fibrewire device (Tightrope® has suggested advantages. However, small case series have reported high soft tissue complication rates. The purpose of our study was to quantify complication rates and further procedures in patients treated with Tightropes. A secondary objective was to determine incidence of complications and further procedures in those treated with syndesmotic screws over the same period.
METHODS: All patients undergoing syndesmotic fixation for ankle fracture between May 2008 and October 2009 were retrospectively reviewed. Incidence of complications, secondary procedures, maintenance of syndesmotic reduction and time spent on non-weight bearing were recorded. Family doctors were contacted for those treated with Tightropes to check for any complications managed elsewhere.
RESULTS: Thirty-five patients required syndesmotic fixation, in which 12 were treated with Tightropes. They were followed up in clinic for a mean of 12.4 weeks. Family doctors were contacted at mean 14.6 months after treatment to determine any complications suffered. There were no complications attributable to method of fixation. In this series, 12 patients underwent 13 procedures and no patient had recurrent diastasis at discharge; 23 patients treated with screw fixation underwent 45 procedures (19 were screw removals). There was 1 case of syndesmotic diastasis. Screw removal resulted in 2 minor complications.
CONCLUSION: Tightrope fixation provideds effective syndesmotic fixation that is maintained at discharge. We do not experience soft tissue complications reported elsewhere.

Entities:  

Mesh:

Year:  2014        PMID: 24506916

Source DB:  PubMed          Journal:  Chin J Traumatol        ISSN: 1008-1275


  2 in total

Review 1.  A meta-analysis comparing the outcomes of syndesmotic injury treated with metal screw, dynamic fixation, and bioabsorbable screw.

Authors:  Jiayong Liu; Gautam Pathak; Mihir Joshi; Kyle Andrews; Joseph Lee
Journal:  J Orthop       Date:  2021-04-24

2.  Dynamic Fixation versus Static Fixation in Treatment Effectiveness and Safety for Distal Tibiofibular Syndesmosis Injuries: A Systematic Review and Meta-Analysis.

Authors:  Xiao Fan; Peng Zheng; Ying-Yu Zhang; Zeng-Tao Hou
Journal:  Orthop Surg       Date:  2019-12       Impact factor: 2.071

  2 in total