Automatic calibration of trigger delay time for cardiac MRI.

Teng-Yi Huang1, Yu-Sheng Tseng, Tzu-Chao Chuang.   

Abstract

This study aimed to automatically identify the cardiac rest period using a rapid free-breathing (FB) calibration scanning procedure, and to determine the optimal trigger delay for cardiac imaging. A standard deviation (SD) method was used to rapidly identify cardiac quiescent phases employing multiphase cine cardiac images. The accuracy of this method was investigated using 46 datasets acquired from 22 healthy volunteers. The possibility of using a low-resolution FB method to rapidly acquire cine images was also evaluated. The reproducibility and accuracy of the trigger delay obtained using the rapid calibration scanning process were assessed before its application to a real-time feedback system. The real-time trigger delay calibration system was then used to perform T1 -weighted, short-axis imaging at the end of the cardiac systolic period. Linear regression analysis of the trigger times obtained using the SD method and a reference method indicated that the SD algorithm accurately identified the cardiac rest period (linear regression: slope = 0.94-1, R(2)  = 0.68-0.84). Group analysis showed that the number of pixels in the left ventricular blood pool in images acquired at the end-systolic time calculated in real time was significantly lower than in those acquired 50 ms in advance or later (p < 0.01, paired t-test). The low-resolution FB imaging method was reproducible for the calibration scanning of an image in a vertical long-axis slice position (average SD of trigger times, 16-39 ms). Combined with rapid FB calibration scanning, the real-time feedback system accurately adjusted the trigger delay for T1 -weighted short-axis imaging. The real-time feedback method is rapid and reliable for trigger time calibration, and could facilitate cardiac imaging during routine examination.
Copyright © 2014 John Wiley & Sons, Ltd.

Keywords:  cardiac imaging; real time; trigger delay

Mesh:

Year:  2014        PMID: 24478224     DOI: 10.1002/nbm.3076

Source DB:  PubMed          Journal:  NMR Biomed        ISSN: 0952-3480            Impact factor:   4.044


  3 in total

Review 1.  Towards accurate and precise T 1 and extracellular volume mapping in the myocardium: a guide to current pitfalls and their solutions.

Authors:  Donnie Cameron; Vassilios S Vassiliou; David M Higgins; Peter D Gatehouse
Journal:  MAGMA       Date:  2017-06-12       Impact factor: 2.310

2.  High efficiency coronary MR angiography with nonrigid cardiac motion correction.

Authors:  Jianing Pang; Yuhua Chen; Zhaoyang Fan; Christopher Nguyen; Qi Yang; Yibin Xie; Debiao Li
Journal:  Magn Reson Med       Date:  2016-07-25       Impact factor: 4.668

Review 3.  A review of 3D first-pass, whole-heart, myocardial perfusion cardiovascular magnetic resonance.

Authors:  Merlin J Fair; Peter D Gatehouse; Edward V R DiBella; David N Firmin
Journal:  J Cardiovasc Magn Reson       Date:  2015-08-01       Impact factor: 5.364

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.