Literature DB >> 24470415

Clinical boundary conditions for grating-based differential phase-contrast mammography.

Ewald Roessl1, Heiner Daerr, Thomas Koehler, Gerhard Martens, Udo van Stevendaal.   

Abstract

Research in grating-based differential phase-contrast imaging (DPCI) has gained increasing momentum in the past couple of years. The first results on the potential clinical benefits of the technique for X-ray mammography are becoming available and indicate improvements in terms of general image quality, the delineation of lesions versus the background tissue and the visibility of microcalcifications. In this paper, we investigate some aspects related to the technical feasibility of DPCI for human X-ray mammography. After a short introduction to state-of-the-art full-field digital mammography in terms of technical aspects as well as clinical aspects, we put together boundary conditions for DPCI. We then discuss the implications for system design in a comparative manner for systems with two-dimensional detectors versus slit-scanning systems, stating advantages and disadvantages of the two designs. Finally, focusing on a slit-scanning system, we outline a possible concept for phase acquisition.

Entities:  

Keywords:  Lau–Talbot interferometry; differential phase-contrast imaging; phase-contrast mammography

Mesh:

Year:  2014        PMID: 24470415     DOI: 10.1098/rsta.2013.0033

Source DB:  PubMed          Journal:  Philos Trans A Math Phys Eng Sci        ISSN: 1364-503X            Impact factor:   4.226


  10 in total

1.  Low-dose, phase-contrast mammography with high signal-to-noise ratio.

Authors:  Lukas B Gromann; Dirk Bequé; Kai Scherer; Konstantin Willer; Lorenz Birnbacher; Marian Willner; Julia Herzen; Susanne Grandl; Karin Hellerhoff; Jonathan I Sperl; Franz Pfeiffer; Cristina Cozzini
Journal:  Biomed Opt Express       Date:  2016-01-07       Impact factor: 3.732

2.  Improved reconstruction of phase-stepping data for Talbot-Lau x-ray imaging.

Authors:  Sebastian Kaeppler; Jens Rieger; Georg Pelzer; Florian Horn; Thilo Michel; Andreas Maier; Gisela Anton; Christian Riess
Journal:  J Med Imaging (Bellingham)       Date:  2017-09-05

3.  Diagnosis of breast cancer based on microcalcifications using grating-based phase contrast CT.

Authors:  Xinbin Li; Hewei Gao; Zhiqiang Chen; Li Zhang; Xiaohua Zhu; Shengping Wang; Weijun Peng
Journal:  Eur Radiol       Date:  2018-01-26       Impact factor: 5.315

4.  Helical X-ray phase-contrast computed tomography without phase stepping.

Authors:  M Marschner; M Willner; G Potdevin; A Fehringer; P B Noël; F Pfeiffer; J Herzen
Journal:  Sci Rep       Date:  2016-04-07       Impact factor: 4.379

5.  Ex Vivo Perfusion-Simulation Measurements of Microbubbles as a Scattering Contrast Agent for Grating-Based X-Ray Dark-Field Imaging.

Authors:  Astrid Velroyen; Martin Bech; Arne Tapfer; Andre Yaroshenko; Mark Müller; Philipp Paprottka; Michael Ingrisch; Clemens C Cyran; Sigrid D Auweter; Konstantin Nikolaou; Maximilian F Reiser; Franz Pfeiffer
Journal:  PLoS One       Date:  2015-07-02       Impact factor: 3.240

6.  Micrometer-resolution imaging using MÖNCH: towards G2-less grating interferometry.

Authors:  Sebastian Cartier; Matias Kagias; Anna Bergamaschi; Zhentian Wang; Roberto Dinapoli; Aldo Mozzanica; Marco Ramilli; Bernd Schmitt; Martin Brückner; Erik Fröjdh; Dominic Greiffenberg; Davit Mayilyan; Davide Mezza; Sophie Redford; Christian Ruder; Lukas Schädler; Xintian Shi; Dhanya Thattil; Gemma Tinti; Jiaguo Zhang; Marco Stampanoni
Journal:  J Synchrotron Radiat       Date:  2016-10-17       Impact factor: 2.616

7.  Revising the lower statistical limit of x-ray grating-based phase-contrast computed tomography.

Authors:  Mathias Marschner; Lorenz Birnbacher; Marian Willner; Michael Chabior; Julia Herzen; Peter B Noël; Franz Pfeiffer
Journal:  PLoS One       Date:  2017-09-06       Impact factor: 3.240

8.  Fast X-ray Differential Phase Contrast Imaging with One Exposure and without Movements.

Authors:  Jian Fu; Xianhong Shi; Wei Guo; Peng Peng
Journal:  Sci Rep       Date:  2019-02-04       Impact factor: 4.379

9.  Implementation of a Talbot-Lau interferometer in a clinical-like c-arm setup: A feasibility study.

Authors:  Florian Horn; Martino Leghissa; Sebastian Kaeppler; Georg Pelzer; Jens Rieger; Maria Seifert; Johannes Wandner; Thomas Weber; Thilo Michel; Christian Riess; Gisela Anton
Journal:  Sci Rep       Date:  2018-02-02       Impact factor: 4.379

10.  Dose-compatible grating-based phase-contrast mammography on mastectomy specimens using a compact synchrotron source.

Authors:  Elena Eggl; Susanne Grandl; Anikό Sztrόkay-Gaul; Martin Dierolf; Christoph Jud; Lisa Heck; Karin Burger; Benedikt Günther; Klaus Achterhold; Doris Mayr; Jan J Wilkens; Sigrid D Auweter; Bernhard Gleich; Karin Hellerhoff; Maximilian F Reiser; Franz Pfeiffer; Julia Herzen
Journal:  Sci Rep       Date:  2018-10-24       Impact factor: 4.379

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.