Literature DB >> 24468241

Simultaneous determination of volatile and non-volatile nitrosamines in processed meat products by liquid chromatography tandem mass spectrometry using atmospheric pressure chemical ionisation and electrospray ionisation.

S S Herrmann1, L Duedahl-Olesen2, K Granby2.   

Abstract

A sensitive, selective and generic method has been developed for the simultaneous determination of the contents (μgkg(-1) range) of both volatile nitrosamines (VNA) and non-volatile nitrosamines (NVNA) in processed meat products. The extraction procedure only requires basic laboratory equipment and a small volume of organic solvent. Separation and quantification were performed by the developed LC-(APCI/ESI)MS/MS method. The method was validated using spiked samples of three different processed meat products. Satisfactory recoveries (50-130%) and precisions (2-23%) were obtained for eight VNA and six NVNAs with LODs generally between 0.2 and 1μgkg(-1), though for a few analyte/matrix combinations higher LODs were obtained (3 to 18μgkg(-1)). The validation results show that results obtained for one meat product is not always valid for other meat products. We were not able to obtain satisfactory results for N-nitrosohydroxyproline (NHPRO), N-nitrosodibenzylamine (NDBzA) and N-nitrosodiphenylamine (NDPhA). Application of the APCI interface improved the sensitivity of the method, because of less matrix interference, and gave the method a wider scope, as some NAs were ionisable only by APCI. However, it was only possible to ionize N-nitroso-thiazolidine-4-carboxylic acid (NTCA) and N-nitroso-2-methyl-thiazolidine-4-carboxylic acid (NMTCA) by ESI. The validated method was applied for the analysis of processed meat products and contents of N-nitrosodimethylamine (NDMA), N-nitrosopyrrolidine (NPYR), N-nitrosomethylaniline (NMA), N-nitrosoproline (NPRO), NTCA, and NMTCA were found in one or several nitrite cured meat products, whereas none were detected in non-nitrite cured bacon.
Copyright © 2014 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Atmospheric pressure chemical ionisation; Electro spray ionisation; Liquid chromatography–tandem mass spectrometry; Non-volatile N-nitrosamines; Processed meat; Volatile N-nitrosamines

Mesh:

Substances:

Year:  2014        PMID: 24468241     DOI: 10.1016/j.chroma.2014.01.009

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  5 in total

1.  Development of GC-MS/MS Method for Simultaneous Estimation of Four Nitrosoamine Genotoxic Impurities in Valsartan.

Authors:  Sambasiva Rao Tummala; Krishnamanjari Pawar Amgoth
Journal:  Turk J Pharm Sci       Date:  2022-08-31

2.  Analysis and health risk assessment of nitrosamines in meat products collected from markets, Iran: with the approach of chemometric.

Authors:  Samin Moradi; Nabi Shariatifar; Behrouz Akbari-Adergani; Ebrahim Molaee Aghaee; Majid Arbameri
Journal:  J Environ Health Sci Eng       Date:  2021-06-21

3.  Absolute Quantitation of N-Nitrosamines by Coulometric Mass Spectrometry without Using Standards.

Authors:  Qi Wang; Zhijian Liu; Yong Liu; Hao Chen
Journal:  J Am Soc Mass Spectrom       Date:  2022-04-21       Impact factor: 3.262

4.  Quantitative Analysis of Eight Triterpenoids and Two Sesquiterpenoids in Rhizoma Alismatis by Using UPLC-ESI/APCI-MS/MS and Its Application to Optimisation of Best Harvest Time and Crude Processing Temperature.

Authors:  Yanni Tai; Fuxian Zou; Qiurong Zhang; Jia Wang; Ronghui Rao; Ruihua Xie; Shuisheng Wu; Kedan Chu; Wen Xu; Xiaoyan Li; Mingqing Huang
Journal:  J Anal Methods Chem       Date:  2019-08-14       Impact factor: 2.193

Review 5.  Chemical hazards in smoked meat and fish.

Authors:  Ogouyôm Herbert Iko Afé; Yénoukounmè Euloge Kpoclou; Caroline Douny; Victor Bienvenu Anihouvi; Ahmed Igout; Jacques Mahillon; Djidjoho Joseph Hounhouigan; Marie-Louise Scippo
Journal:  Food Sci Nutr       Date:  2021-10-18       Impact factor: 2.863

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.