Luiz Garcia Mandarano-Filho1, Márcio Takey Bezuti1, Nilton Mazzer1, Cláudio Henrique Barbieri1.
Abstract
OBJECTIVE: An experimental in vitro study was carried out to evaluate the influence of cortical bone thickness on ultrasound propagation velocity.Entities:
Keywords: Acoustics; Bone and bones; Ultrasonics
Year: 2012 PMID: 24453601 PMCID: PMC3718431 DOI: 10.1590/S1413-78522012000300010
Source DB: PubMed Journal: Acta Ortop Bras ISSN: 1413-7852 Impact factor: 0.513
Figure 1Image of the wave emitted and received visualized in the oscilloscope.
Figure 2Measurement of ultrasound velocity via the axial direct contact technique.
Figure 3Measurement of ultrasound velocity via the transverse direct contact technique.
Figure 4Measurement of ultrasound velocity via the transverse underwater technique.
Study design. ADC: Axial direct contact, TDC: Transverse direct contact, AUW: axial underwater, TUW: transverse underwater.
| 1 | 10 | ADC, TDC, AUW and TUW |
| 2 | 10 | ADC, TDC, AUW and TUW |
| 3 | 10 | ADC, TDC, AUW and TUW |
| 4 | 10 | ADC, TDC, AUW and TUW |
| 5 | 10 | ADC, TDC, AUW and TUW |
| 6 | 10 | ADC, TDC, AUW and TUW |
Description of the velocities obtained with the direct contact technique with axial transmission, for the distances of 3, 5 and 7cm between the transducers.
| Mean (m/s) | SD | Mean (m/s) | SD | Mean (m/s) | SD | Mean (m/s) | SD | Mean (m/s) | SD | Mean (m/s) | SD | ||
| 3 | 3491.4 | 2.55 | 3650.1 | 1.52 | 33802.8 | 2.3 | 3998.2 | 2.3 | 4200.9 | 1.79 | 4201.2 | 2.15 | |
| ADC 5 | 3497.5 | 3.81 | 3650.1 | 3 | 3800.4 | 3.57 | 4001 | 4.67 | 4199.3 | 1.7 | 4200.3 | 2.45 | |
| 7 | 3497.9 | 5.36 | 3651 | 2.67 | 3799.5 | 4.03 | 3998.1 | 2.92 | 4200.3 | 2.63 | 4200.6 | 1.35 | |
ADC: Axial direct contact; mm: millimeters; SD.: standard deviation.
Description of the velocities obtained with the underwater technique with axial transmission, for the distances of 3, 5 and 7cm between the transducers.
| Mean (m/s) | SD | Mean (m/s) | SD | Mean (m/s) | SD | Mean (m/s) | SD | Mean (m/s) | SD | Mean (m/s) | SD | ||
| 3 | 3498.9 | 7.14 | 3651 | 5.37 | 3800 | 5.52 | 3998.1 | 5.84 | 4199.6 | 6.75 | 4200.2 | 6.16 | |
| AUW 5 | 3493.1 | 4.63 | 3649.9 | 5.28 | 3798.7 | 3.4.27 | 3999.9 | 5.95 | 4201 | 5.06 | 4201.1 | 4.75 | |
| 7 | 3491.7 | 4.76 | 3649 | 3.89 | 3804.2 | 4.18 | 3998.8 | 4.94 | 4202.1 | 2.69 | 4200.1.6 | 2.85 | |
AUW: Axial underwater; mm: millimeters; SD.: standard deviation.
Figure 5Box plot of comparison of the USPV in the different thicknesses and with the direct contact and underwater techniques, for axial transmission with a distance of 3, 5 and 7cm between the transducers.
Description of the velocities obtained with the direct contact and underwater techniques for transverse transmission, with the 6 plate thicknesses.
| Mean (m/s) | SD | Mean (m/s) | SD | Mean (m/s) | SD | Mean (m/s) | SD | Mean (m/s) | SD | Mean (m/s) | SD | |
| TDC | 3438 | 9.12 | 3442 | 12.2 | 3439 | 10.2 | 3441 | 11.8 | 3436 | 11.5 | 3441 | 9.96 |
| TUW | 3440 | 11.9 | 3440 | 8.75 | 3437 | 13.6 | 3443 | 11.5 | 3441 | 11.4 | 3437 | 8.44 |
TDC: transverse direct contact; TUW: transverse underwater; SD.: standard deviation.
Figure 6Comparison of TDC and TUW for the thicknesses of 1mm to 6mm of the bone plates.