Literature DB >> 24448288

Safety and functional results of early cochlear implant switch-on in children.

Pasquale Marsella1, Alessandro Scorpecci, Concettina Pacifico, Alessandra Resca, Maria Vittoria Vallarino, Angelo Ingrosso, Stefania Luchenti.   

Abstract

OBJECTIVE: To assess the safety and the possible advantages of early (1-wk) cochlear implant switch-on in children and to compare impedance and ECAP threshold changes between subjects undergoing early switch-on and those undergoing traditional, 1-month switch-on. STUDY
DESIGN: Prospective cohort study.
SETTING: Tertiary care referral pediatric center. PATIENTS: Seventeen children receiving a unilateral or bilateral Nucleus Freedom cochlear implant were included, for a total of 20 ears. Ten ears were assigned to the early (1-wk) switch-on group and 10 to the control group (switch-on after 4 wks).
INTERVENTIONS: Common ground impedance values and electrically evoked compound action potential thresholds were measured from intraoperation until 9 months postoperatively. Speech perception improvements over time were also assessed. MAIN OUTCOME MEASURES: Complication rate, impedance levels (kΩ), and electrically evoked compound action potentials (current levels)
RESULTS: Early switch-on was well tolerated by patients and did not cause complications. Impedances dropped significantly after switch-on in both groups. They also seemed to achieve an earlier stability in the early switch-on patients, although the difference between groups was not significant. ECAP thresholds showed a similar, nonsignificant decreasing trend over time in both groups. Speech perception improvements did not differ between groups.
CONCLUSION: This is the first study investigating the safety and the effects of an early cochlear implant switch-on in children. Results show that such a procedure is well tolerated by pediatric subjects and free from complications. Impedance measurements suggest that the earlier switched-on subjects benefit of lower and more stable impedances than subjects undergoing 1-month switch-on.

Entities:  

Mesh:

Year:  2014        PMID: 24448288     DOI: 10.1097/MAO.0000000000000259

Source DB:  PubMed          Journal:  Otol Neurotol        ISSN: 1531-7129            Impact factor:   2.311


  4 in total

1.  Achieving early functional auditory access in paediatric cochlear implantation.

Authors:  E Orzan; E Muzzi; R Marchi; C Falzone; S Battelino; E Ciciriello
Journal:  Acta Otorhinolaryngol Ital       Date:  2016-02-29       Impact factor: 2.124

2.  Evolution of impedance field telemetry after one day of activation in cochlear implant recipients.

Authors:  Hao-Chun Hu; Joshua Kuang-Chao Chen; Chia-Mi Tsai; Hsing-Yi Chen; Tao-Hsin Tung; Lieber Po-Hung Li
Journal:  PLoS One       Date:  2017-03-06       Impact factor: 3.240

3.  Exploiting Routine Clinical Measures to Inform Strategies for Better Hearing Performance in Cochlear Implant Users.

Authors:  Alan P Sanderson; Edward T F Rogers; Carl A Verschuur; Tracey A Newman
Journal:  Front Neurosci       Date:  2019-01-15       Impact factor: 4.677

4.  Methods for measuring pre-, intra-, and postoperative skin thickness for cochlear implants.

Authors:  Lena Zaubitzer; Elena Schaefer; Elisabeth Wallhaeuser-Franke; Johannes Burkart; Katrin Herrmann; Beatrice Walter; Angela Schell; Claudia Scherl; Jérôme Servais; Daniel Haeussler
Journal:  J Otol       Date:  2021-12-16
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.