Literature DB >> 24447139

Educational intervention to reduce inappropriate transthoracic echocardiograms: the need for sustained intervention.

Rajan Sacha Bhatia1, David M Dudzinski, Creagh E Milford, Michael H Picard, Rory B Weiner.   

Abstract

BACKGROUND: We previously demonstrated that an Appropriate Use Criteria (AUC)-based educational intervention reduced inappropriate transthoracic echocardiograms (TTE) on an inpatient medical service. Whether improved TTE ordering is sustained after discontinuation of the intervention is unknown.
METHODS: We conducted a prospective, time series analysis of an educational intervention designed to reduce inappropriate TTE. Ordering patterns during the intervention were compared with a preintervention control period and a postintervention period. The goal of the present analysis was to determine the TTE ordering patterns after discontinuation of the educational intervention. The primary outcome was the proportion of inappropriate TTEs.
RESULTS: Using the 2011 AUC 99.2% of all TTEs were classifiable. Compared to the control, there was a 26% reduction in the number of TTEs ordered per day during the intervention (3.9 vs. 2.9 TTEs, P < 0.001), but no significant difference between the intervention and postintervention periods (2.9 vs. 3.1, P = 0.23). The intervention produced a decrease in the inappropriate TTE rate and an increase in the appropriate TTE rate. Compared to the intervention, in the postintervention period the rate of inappropriate TTEs increased (5% vs. 11%, P = 0.01) and appropriate TTEs decreased (93% vs. 86%, P = 0.008). The postintervention rate of inappropriate TTEs was similar to the preintervention control period (11% vs. 13%, P = 0.23).
CONCLUSIONS: Following completion of an AUC-based educational intervention the proportion of inappropriate TTEs increased to the preintervention level. The long-term success of an intervention designed to improve appropriate utilization of TTE requires a sustained effort of education and feedback.
© 2014, Wiley Periodicals, Inc.

Keywords:  appropriate use criteria; feedback; resident education; transthoracic echocardiography

Mesh:

Year:  2014        PMID: 24447139     DOI: 10.1111/echo.12505

Source DB:  PubMed          Journal:  Echocardiography        ISSN: 0742-2822            Impact factor:   1.724


  5 in total

1.  A systematic review of Appropriate Use Criteria for transthoracic echocardiography: are they relevant outside the United States?

Authors:  Robert N Kerley; Siun O'Flynn
Journal:  Ir J Med Sci       Date:  2018-06-18       Impact factor: 1.568

2.  Improving the diagnostic workup of hyponatremia in the setting of kidney disease: a continuing medical education (CME) initiative.

Authors:  Ladan Golestaneh; Joel Neugarten; William Southern; Faraj Kargoli; Amanda Raff
Journal:  Int Urol Nephrol       Date:  2017-01-13       Impact factor: 2.370

3.  Effects of an Electronic Medical Record Intervention on Appropriateness of Transthoracic Echocardiograms: A Prospective Study.

Authors:  Weihan Chen; David T Saxon; Michael P Henry; John R Herald; Rob Holleman; Debbie Zawol; Stacy Sivils; Mohamad A Kenaan; Theodore J Kolias; Hitinder S Gurm; Nicole M Bhave
Journal:  J Am Soc Echocardiogr       Date:  2020-11-01       Impact factor: 5.251

4.  Clinical Practice Guidelines on Ordering Echocardiography Before Hip Fracture Repair Perform Differently from One Another.

Authors:  Eric Swart; Chris Adair; Rachel B Seymour; Madhav A Karunakar
Journal:  HSS J       Date:  2020-06-08

5.  Physicians' professional identities: a roadmap to understanding "value" in cardiovascular imaging.

Authors:  Eric J Keller; Robert L Vogelzang; Benjamin H Freed; James C Carr; Jeremy D Collins
Journal:  J Cardiovasc Magn Reson       Date:  2016-08-26       Impact factor: 5.364

  5 in total