Literature DB >> 24445796

[Turbulence and high intensity transient signals (HITS) as a parameter for optimum orientation of mechanical heart valves].

M Perthel1, J M Hasenkam, H Nygaard, W Kupper, J Laas.   

Abstract

BACKGROUND: In previous studies, the impact of valve orientation on the hemodynamic performance of mechanical aortic valves has been demonstrated. This study investigates Turbulence (RNS values) and High Intensity Transient Signals (HITS) as a new and objective parameter for hemodynamics in various orientations of Medtronic Hall (MH) and St. Jude Medical (SJM) aortic valves.
METHODS: Rotation devices carrying a MH or SJM valve were implanted into four pigs. The device allowed valve rotation without reopening the aorta. In various orientations, turbulent shear stresses (RNS values) and HITS were measured.
RESULTS: RNS and HITS changed for both valve designs in the different orientations, with superior results for the MH in the hemodynamically best orientation. Downstream turbulence (RNS) and HITS varied in the same direction, but a one to one correlation was not observed.
CONCLUSIONS: RNS and HITS vary with respect to valve orientation and design with superior results for the tilting disc valve. Both MH and SJM valves showed lower turbulence and HITS counts in their hemodynamically best orientations. HITS were related to downstream turbulence and the hemodynamic performance of the mechanical aortic valves.

Entities:  

Year:  2001        PMID: 24445796     DOI: 10.1007/PL00007322

Source DB:  PubMed          Journal:  Z Kardiol        ISSN: 0300-5860


  15 in total

1.  Platelet aggregation and high-intensity transient signals (HITS) in a sheep model of mitral valve replacement.

Authors:  L Raco; P R Belcher; I Sim; A McGarrity; G M Bernacca; D J Wheatley
Journal:  J Heart Valve Dis       Date:  1999-09

2.  Orientation of tilting disc and bileaflet aortic valve substitutes for optimal hemodynamics.

Authors:  J Laas; P Kleine; M J Hasenkam; H Nygaard
Journal:  Ann Thorac Surg       Date:  1999-09       Impact factor: 4.330

3.  Prospective evaluation of frequency and nature of transcranial high-intensity Doppler signals in prosthetic valve recipients.

Authors:  A Milano; A D'Alfonso; R Codecasa; M De Carlo; C Nardi; G Orlandi; L Landucci; U Bortolotti
Journal:  J Heart Valve Dis       Date:  1999-09

4.  Downstream turbulence and high intensity transient signals (HITS) following aortic valve replacement with Medtronic Hall or St. Jude Medical valve substitutes.

Authors:  P Kleine; M Perthel; J M Hasenkam; H Nygaard; S B Hansen; J Laas
Journal:  Eur J Cardiothorac Surg       Date:  2000-01       Impact factor: 4.191

5.  Assessment of small-diameter aortic mechanical prostheses: physiological relevance of the Doppler gradient, utility of flow augmentation, and limitations of orifice area estimation.

Authors:  R H Marcus; R S Heinrich; J Bednarz; S Lupovitch; J Abruzzo; R Borok; B Vandenberg; R E Kerber; W Piccione; A P Yoganathan; R M Lang
Journal:  Circulation       Date:  1998-09-01       Impact factor: 29.690

6.  On the origin of cerebrovascular microemboli associated with prosthetic heart valves.

Authors:  T G Mackay; D Georgiadis; D G Grosset; K R Lees; D J Wheatley
Journal:  Neurol Res       Date:  1995-10       Impact factor: 2.448

7.  Clinical correlations of Doppler microembolic signals in patients with prosthetic cardiac valves: analysis of 580 cases.

Authors:  U Sliwka; D Georgiadis
Journal:  Stroke       Date:  1998-01       Impact factor: 7.914

8.  Intracavitary echoes in patients with mitral prosthetic valves.

Authors:  H Schuchman; H Feigenbaum; J C Dillon; S Chang
Journal:  J Clin Ultrasound       Date:  1975-06       Impact factor: 0.910

9.  Can cerebrovascular microemboli induce cognitive impairment in patients with prosthetic heart valves?

Authors:  G Deklunder; A Prat; J L Lecroart; M Roussel; M Dauzat
Journal:  Eur J Ultrasound       Date:  1998-02

10.  Differentiation between different pathological cerebral embolic materials using transcranial Doppler in an in vitro model.

Authors:  H S Markus; M M Brown
Journal:  Stroke       Date:  1993-01       Impact factor: 7.914

View more