Literature DB >> 24444444

Clinical predictors of adverse patient outcomes in an experience of more than 5000 chronic endovascular pacemaker and defibrillator lead extractions.

Michael P Brunner1, Edmond M Cronin1, Valeria E Duarte2, Changhong Yu3, Khaldoun G Tarakji1, David O Martin1, Thomas Callahan1, Daniel J Cantillon1, Mark J Niebauer1, Walid I Saliba1, Mohamed Kanj1, Oussama Wazni1, Bryan Baranowski1, Bruce L Wilkoff4.   

Abstract

BACKGROUND: It is difficult to predict adverse patient outcomes associated with transvenous lead extraction (TLE) procedures.
OBJECTIVE: The purpose of this study was to examine the safety and efficacy of chronic endovascular pacemaker and implantable cardioverter-defibrillator (ICD) lead extraction and risk factors associated with adverse patient outcomes.
METHODS: Consecutive patients undergoing TLE at the Cleveland Clinic between August 1996 and August 2011 were included in the analysis. Univariate and multivariable logistic regression analyses were performed to evaluate for associations with outcomes. Continuous data are given as median (25th, 75th percentile). Categorical data are given as number (percentage).
RESULTS: In total, 5521 leads (4137 [74.9%] pacemaker, 1384 [25.1%] ICD) were extracted during 2999 TLE procedures (patient age 67.2 [55.2, 76.2] years, 30.2% female). Lead implant duration was 4.7 (2.4, 8.3) years, and 2.0 (1.0, 2.0) leads were extracted per procedure. Powered sheaths were used in 74.9% of procedures. Overall, there was 95.1% complete procedural success, 98.9% clinical success, and 1.1% failure, with 3.6% minor complications and 1.8% major complications. All-cause mortality within 30 days of TLE was 2.2%. Multivariable predictors of major complications included cerebrovascular disease, ejection fraction ≤15%, lower platelet count, international normalized ratio ≥1.2, mechanical sheaths, and powered sheaths. Multivariable predictors of all-cause mortality within 30 days of TLE included body mass index <25 kg/m(2), end-stage renal disease, higher New York Heart Association functional class, lower hemoglobin, higher international normalized ratio, lead extraction for infection, and extraction of a dual-coil ICD lead.
CONCLUSION: TLE in this single-center experience was highly successful. Risk factors associated with adverse patient outcomes were identified.
Copyright © 2014 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Complications; Extraction; Implantable cardioverter defibrillator; Lead; Pacemaker

Mesh:

Year:  2014        PMID: 24444444     DOI: 10.1016/j.hrthm.2014.01.016

Source DB:  PubMed          Journal:  Heart Rhythm        ISSN: 1547-5271            Impact factor:   6.343


  33 in total

Review 1.  Should His Bundle Pacing Be Preferred over Cardiac Resynchronization Therapy Following Atrioventricular Junction Ablation?

Authors:  Zak Loring; Albert Y Sun
Journal:  Cardiol Clin       Date:  2019-02-10       Impact factor: 2.213

2.  Cardiac Implantable Electronic Device Infection in Patients at Risk.

Authors:  Khaldoun G Tarakji; Christopher R Ellis; Pascal Defaye; Charles Kennergren
Journal:  Arrhythm Electrophysiol Rev       Date:  2016-05

3.  Outcomes 1 Year After Implantable Cardioverter-Defibrillator Lead Abandonment Versus Explantation for Unused or Malfunctioning Leads: A Report from the National Cardiovascular Data Registry.

Authors:  Emily P Zeitler; Yongfei Wang; Kumar Dharmarajan; Kevin J Anstrom; Eric D Peterson; James P Daubert; Jeptha P Curtis; Sana M Al-Khatib
Journal:  Circ Arrhythm Electrophysiol       Date:  2016-07

4.  Comparison of single-coil lead versus dual-coil lead of implantable cardioverter defibrillator on lead-related venous complications in a canine model.

Authors:  Ziqing Yu; Yuan Wu; Shengmei Qin; Jingfeng Wang; Xueying Chen; Ruizhen Chen; Yangang Su; Junbo Ge
Journal:  J Interv Card Electrophysiol       Date:  2018-03-23       Impact factor: 1.900

5.  Echocardiographic assessment of residuals after transvenous intracardiac lead extraction.

Authors:  Magdalena Poterała; Andrzej Kutarski; Wojciech Brzozowski; Michał Tomaszewski; Leszek Gromadziński; Andrzej Tomaszewski
Journal:  Int J Cardiovasc Imaging       Date:  2019-11-16       Impact factor: 2.357

6.  Management of Cardiac Electronic Device Infections: Challenges and Outcomes.

Authors:  Rikke Esberg Kirkfeldt; Jens Brock Johansen; Jens Cosedis Nielsen
Journal:  Arrhythm Electrophysiol Rev       Date:  2016

7.  Outcomes of subcutaneous implantable cardioverter-defibrillator implantation in patients on hemodialysis.

Authors:  Eduard Koman; Ashwani Gupta; Faiz Subzposh; Heath Saltzman; Steven P Kutalek
Journal:  J Interv Card Electrophysiol       Date:  2016-01-14       Impact factor: 1.900

8.  New-onset pericardial effusion during transvenous lead extraction: incidence, causative mechanisms, and associated factors.

Authors:  François Regoli; Gabriele D'Ambrosio; Maria Luce Caputo; Stefano Svab; Giulio Conte; Tiziano Moccetti; Catherine Klersy; Tiziano Cassina; Stefanos Demertzis; Angelo Auricchio
Journal:  J Interv Card Electrophysiol       Date:  2018-02-23       Impact factor: 1.900

9.  Contemporary rates and outcomes of single- vs. dual-coil implantable cardioverter defibrillator lead implantation: data from the Israeli ICD Registry.

Authors:  Eran Leshem; Mahmoud Suleiman; Avishag Laish-Farkash; Yuval Konstantino; Michael Glikson; Alon Barsheshet; Ilan Goldenberg; Yoav Michowitz
Journal:  Europace       Date:  2017-09-01       Impact factor: 5.214

10.  Effectiveness and Safety of Transvenous Removal of Cardiac Pacing and Implantable Cardioverter-defibrillator Leads in the Real Clinical Scenario.

Authors:  Roberto Costa; Katia Regina da Silva; Elizabeth Sartori Crevelari; Wagner Tadeu Jurevicius Nascimento; Marcia Mitie Nagumo; Martino Martinelli Filho; Fabio Biscegli Jatene
Journal:  Arq Bras Cardiol       Date:  2020-12       Impact factor: 2.000

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.