Literature DB >> 24440330

Comparison of the safety and feasibility of arrhythmia ablation using the Amigo Robotic Remote Catheter System versus manual ablation.

Tomás Datino1, Angel Arenal2, Mauricio Pelliza2, Jesús Hernández-Hernández2, Felipe Atienza2, Esteban González-Torrecilla2, Pablo Avila2, Loreto Bravo2, Francisco Fernández-Avilés2.   

Abstract

The aim of this study is to evaluate the safety and feasibility of using the Amigo Remote Catheter System (RCS) in arrhythmia ablation procedures. Because Amigo allows the physician to operate all catheter function outside of the radiation field, operator exposure time was also evaluated. This is a nonrandomized, prospective clinical trial conducted at 1 site (identifier: NCT01834872). The study prospectively enrolled 50 consecutive patients (mean age 59 ± 15 years, 72% men) with any type of arrhythmia (23 atrial fibrillation ablation, 12 common atrial flutters, 10 patients with other supraventricular tachycardia, 4 ventricular tachycardia, and 1 patient with palpitations with no arrhythmia induced) referred for catheter ablation, in which we used RCS. Fifty matched ablation procedures (mean age 57 ± 14 years, 70% men) performed during the same time period, without RCS, were enrolled into the control group. Acute ablation success was 96% with RCS and 98% in the manual group. In only 2 cases, the physician switched to manual ablation (1 ventricular tachycardia and 1 accessory pathway) to complete the procedure. There were no complications related to the use of RCS. No differences were observed in total procedure time, total fluoroscopy time, or total radiofrequency delivery compared with the manual group. In procedures performed with RCS, the operator's fluoroscopy exposure time was reduced by 68 ± 16%. In conclusion, arrhythmia ablation with RCS is safe and feasible. Furthermore, it significantly reduces operator's exposure to radiation.
Copyright © 2014 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2013        PMID: 24440330     DOI: 10.1016/j.amjcard.2013.11.030

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  7 in total

Review 1.  Conceptual Design and Procedure for an Autonomous Intramyocardial Injection Catheter.

Authors:  Weyland Cheng; Peter K Law
Journal:  Cell Transplant       Date:  2016-12-07       Impact factor: 4.064

Review 2.  Review of emerging surgical robotic technology.

Authors:  Brian S Peters; Priscila R Armijo; Crystal Krause; Songita A Choudhury; Dmitry Oleynikov
Journal:  Surg Endosc       Date:  2018-02-13       Impact factor: 4.584

3.  Robotics for neuroendovascular intervention: Background and primer.

Authors:  Kazim H Narsinh; Ricardo Paez; Kerstin Mueller; M Travis Caton; Amanda Baker; Randall T Higashida; Van V Halbach; Christopher F Dowd; Matthew R Amans; Steven W Hetts; Alexander M Norbash; Daniel L Cooke
Journal:  Neuroradiol J       Date:  2021-08-16

4.  Robotic ablation of atrial fibrillation.

Authors:  Alexander Wutzler; Thomas Wolber; Wilhelm Haverkamp; Leif-Hendrik Boldt
Journal:  J Vis Exp       Date:  2015-05-29       Impact factor: 1.355

5.  Remotely controlled steerable sheath improves result and procedural parameters of atrial fibrillation ablation with magnetic navigation.

Authors:  Abdelkarim Errahmouni; Decebal Gabriel Latcu; Sok-Sithikun Bun; Nicolas Rijo; Céline Dugourd; Nadir Saoudi
Journal:  Europace       Date:  2015-02-05       Impact factor: 5.214

6.  Safety and feasibility of atrial fibrillation ablation using Amigo® system versus manual approach: A pilot study.

Authors:  Antonio Scarà; Luigi Sciarra; Ermenegildo De Ruvo; Alessio Borrelli; Domenico Grieco; Zefferino Palamà; Paolo Golia; Lucia De Luca; Marco Rebecchi; Leonardo Calò
Journal:  Indian Pacing Electrophysiol J       Date:  2017-11-01

7.  Feedforward Coordinate Control of a Robotic Cell Injection Catheter.

Authors:  Weyland Cheng; Peter K Law
Journal:  Cell Transplant       Date:  2017-08       Impact factor: 4.064

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.