Literature DB >> 24439502

Improvement in the sensitivity of microfluidic ELISA through field amplified stacking of the enzyme reaction product.

Basant Giri1, Debashis Dutta2.   

Abstract

In this article, we demonstrate a novel approach to enhancing the sensitivity of enzyme-linked immunosorbent assays (ELISA) through pre-concentration of the enzyme reaction product (resorufin/4-methylumbelliferone) in free solution. The reported pre-concentration was accomplished by transporting the resorufin/4-methylumbelliferone molecules produced in the ELISA process towards a high ionic-strength buffer stream in a microfluidic channel while applying a voltage drop across this merging region. A sharp change in the electric field around the junction of the two liquid streams was observed to abruptly slow down the negatively charged resorufin/4-methylumbelliferone species leading to the reported pre-concentration effect based on the field amplified stacking (FAS) technique. It has been shown that the resulting enhancement in the detectability of the enzyme reaction product significantly improves the signal-to-noise ratio in the system thereby reducing the smallest detectable analyte concentration in the ELISA method. Applying the above-described approach, we were able to detect mouse anti-BSA and human TNF-α at concentrations nearly 60-fold smaller than that possible on commercial microwell plates. For the human TNF-α sample, this improvement in assay sensitivity corresponded to a limit of detection (LOD) of 0.102pg mL(-1) using the FAS based microfluidic ELISA method as compared to 7.03pg mL(-1) obtained with the traditional microwell plate based approach. Moreover, because our ELISAs were performed in micrometer sized channels, they required sample volumes about two orders of magnitude smaller than that consumed in the latter case (1μL versus 100μL).
Copyright © 2013 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Enzyme-linked immunosorbent assay; Field amplified stacking; Microfluidic; Pre-concentration; TNF-α

Mesh:

Substances:

Year:  2013        PMID: 24439502     DOI: 10.1016/j.aca.2013.12.007

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  4 in total

1.  Electrokinetic stacking of particle zones in confined channels enabling their UV absorbance detection on microchips.

Authors:  Ling Xia; Rajesh Deb; Debashis Dutta
Journal:  Anal Chim Acta       Date:  2020-08-22       Impact factor: 6.558

2.  Undergraduate Laboratory Module for Implementing ELISA on the High Performance Microfluidic Platform.

Authors:  Basant Giri; Ravichander R Peesara; Naoki Yanagisawa; Debashis Dutta
Journal:  J Chem Educ       Date:  2015       Impact factor: 2.979

3.  Rapid Mouse Follicle Stimulating Hormone Quantification and Estrus Cycle Analysis Using an Automated Microfluidic Chemiluminescent ELISA System.

Authors:  Xiaotian Tan; Anu David; James Day; Haoyue Tang; Emily Rose Dixon; Hongbo Zhu; Yu-Cheng Chen; Maung Kyaw Khaing Oo; Ariella Shikanov; Xudong Fan
Journal:  ACS Sens       Date:  2018-10-29       Impact factor: 7.711

4.  Microfluidic ELISA employing an enzyme substrate and product species with similar detection properties.

Authors:  Basant Giri; Yukari Liu; Fidelis N Nchocho; Robert C Corcoran; Debashis Dutta
Journal:  Analyst       Date:  2018-02-12       Impact factor: 4.616

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.