Manual versus automatic detection of aortic annulus plane in a computed tomography scan for transcatheter aortic valve implantation screening.

Arnaud Van Linden1, Jörg Kempfert2, Johannes Blumenstein3, Helge Möllmann3, Won-Keun Kim4, Serap Alkaya2, Christian Hamm3, Thomas Walther2.   

Abstract

OBJECTIVES: Precise measurements of aortic annulus dimensions are crucial for prosthesis size selection in patients undergoing transcatheter aortic valve implantation (TAVI). The so-called effective diameter (derived from area) measured in multislice computed tomography (MSCT) images has evolved to be the most precise measurement tool. Usually, the operator must manually adjust the aortic annular plane. Syngo Aortic ValveGuide (Siemens Healthcare) is a new software tool that allows for automatic aortic root reconstruction and annular plane detection. The aim of this study was to compare the effective diameter measured in automatically detected and manually adjusted annular plane.
METHODS: Seventy-three raw image datasets of preoperative TAVI MSCT scans were analysed using our institutional gold standard (3Mensio Valves™) with manual annular plane adjustment and using Aortic ValveGuide with automatic annular plane detection. The aortic annular circumference was manually marked for both software tools, and the effective diameter was calculated using the formula: effective diameter = 2 × √(circumferential area/π).
RESULTS: Automatic annulus plane detection using Syngo Aortic ValveGuide worked well in all MSCT scans. Minor manual adjustment of the detected plane was necessary in only 3 patients. The mean effective aortic annulus diameter was 23.1 ± 2.4 mm for 3Mensio and 23.3 ± 2.4 mm for Syngo Aortic ValveGuide. Bland-Altman analysis of both imaging software tools showed good agreement (mean difference of 0.16 mm and limits of agreement of -0.48 to 0.80 mm).
CONCLUSIONS: Effective aortic annulus diameter measured with Syngo Aortic ValveGuide, as a new imaging software that allows for automatic aortic annular plane detection, shows good agreement to gold standard measurements. Automatic annulus plane detection might reduce the effort for MSCT analysis and may lead to more reproducible aortic annulus measurements. Aortic ValveGuide is part of the DynaCT and in future aortic annulus dimension measurements may be feasible during intraoperatively acquired DynaCT.
© The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

Entities:  

Keywords:  Aortic Annulus; Multislice computed tomography; Sizing; Transcatheter aortic valve implantation

Mesh:

Year:  2014        PMID: 24431165     DOI: 10.1093/ejcts/ezt600

Source DB:  PubMed          Journal:  Eur J Cardiothorac Surg        ISSN: 1010-7940            Impact factor:   4.191


  8 in total

1.  CT evaluation prior to transapical aortic valve replacement: semi-automatic versus manual image segmentation.

Authors:  Borek Foldyna; Camelia Jungert; Christian Luecke; Konstantin von Aspern; Sonja Boehmer-Lasthaus; Eva Maria Rueth; Matthias Grothoff; Stefan Nitzsche; Matthias Gutberlet; Friedrich Wilhelm Mohr; Lukas Lehmkuhl
Journal:  Int J Cardiovasc Imaging       Date:  2015-04-19       Impact factor: 2.357

Review 2.  CT support of cardiac structural interventions.

Authors:  Michaela M Hell; Stephan Achenbach
Journal:  Br J Radiol       Date:  2019-03-11       Impact factor: 3.039

3.  Semi-automatic CT-angiography based evaluation of the aortic annulus in patients prior to TAVR: interchangeability with manual measurements.

Authors:  Dominik Zinsser; Alena B Baumann; Katharina Stella Winter; Fabian Bamberg; Philipp Lange; Konstantin Nikolaou; Maximilian Reiser; Christian Kupatt; Thomas Kröncke; Florian Schwarz
Journal:  Int J Cardiovasc Imaging       Date:  2018-06-05       Impact factor: 2.357

4.  Computer-aided evaluation of low-dose and low-contrast agent third-generation dual-source CT angiography prior to transcatheter aortic valve implantation (TAVI).

Authors:  Peter Dankerl; Matthias Hammon; Hannes Seuss; Monique Tröbs; Annika Schuhbaeck; Michaela M Hell; Alexander Cavallaro; Stephan Achenbach; Michael Uder; Mohamed Marwan
Journal:  Int J Comput Assist Radiol Surg       Date:  2016-09-07       Impact factor: 2.924

5.  A fully automated software platform for structural mitral valve analysis.

Authors:  Simon S Martin; Richard R Bayer; Robert Steinbach; U Joseph Schoepf; L Parkwood Griffith; Marly van Assen; Matthias Renker; Pooyan Sahbaee; Chris Schwemmer; Andreas M Fischer; Akos Varga-Szemes
Journal:  Eur Radiol       Date:  2020-07-02       Impact factor: 5.315

6.  Effective diameter of the aortic annulus prior to transcatheter aortic valve implantation: influence of area-based versus perimeter-based calculation.

Authors:  K von Aspern; B Foldyna; C D Etz; A Hoyer; F Girrbach; D Holzhey; C Lücke; M Grothoff; A Linke; F W Mohr; M Gutberlet; L Lehmkuhl
Journal:  Int J Cardiovasc Imaging       Date:  2014-08-28       Impact factor: 2.357

7.  Aortic root evaluation prior to transcatheter aortic valve implantation-Correlation of manual and semi-automatic measurements.

Authors:  Barbora Horehledova; Casper Mihl; Chris Schwemmer; Babs M F Hendriks; Nienke G Eijsvoogel; Bastiaan L J H Kietselaer; Joachim E Wildberger; Marco Das
Journal:  PLoS One       Date:  2018-06-28       Impact factor: 3.240

8.  Automatic Detection of the Aortic Annular Plane and Coronary Ostia from Multidetector Computed Tomography.

Authors:  Patricio Astudillo; Peter Mortier; Johan Bosmans; Ole De Backer; Peter de Jaegere; Francesco Iannaccone; Matthieu De Beule; Joni Dambre
Journal:  J Interv Cardiol       Date:  2020-05-28       Impact factor: 2.279

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.