Our experience with the titanium soft clip piston stapedotomy.

P P Singh1, Arun Goyal2.   

Abstract

The crimping of stapes prosthesis to the long process of incus has always been the bugbear of an otologist. Malcrimping on one hand can lead to necrosis of the long process on the other it can lead to a residual air-bone gap or a postoperative reappearance of the conductive hearing loss. To solve these problems different types of stapes prostheses having different techniques to achieve a secure attachment to incus have been devised. Retrospective analysis of patient data. Tertiary care hospital. Case records of 20 patients of otosclerosis who had undergone stapedotomy using titanium soft clip stapes piston (Kurz, Germany) were retrospectively analysed. This new type of stapes piston is a modification of the earlier àWengen clip piston (Kurz, Germany) which was designed to avoid the crimping onto the incus in stapedotomy. Hearing results were analyzed using American Academy of Otolaryngology-Head and Neck Surgery guidelines including 4 frequency pure tone average. The mean postoperative air-bone gap was with in 10 dB in 8 (40% of cases), up to 15 dB in another 8 (40%) cases and in rest 4 (20%) was with in 20 dB. No adverse reactions occurred during follow-up. The use of the titanium soft clip stapes piston gives good results in cases of stapedotomy for otosclerosis. The soft clip design is a new development in the evolution of stapes piston prostheses. Surgical introduction, placement, and fixation are easier than the earlier àWengen design of clip piston.

Entities:  

Keywords:  Clip piston; Otosclerosis; Stapedotomy

Year:  2012        PMID: 24427582      PMCID: PMC3696166          DOI: 10.1007/s12070-011-0459-4

Source DB:  PubMed          Journal:  Indian J Otolaryngol Head Neck Surg        ISSN: 2231-3796


  6 in total

1.  Fenestration of the oval window.

Authors:  J J SHEA
Journal:  Ann Otol Rhinol Laryngol       Date:  1958-12       Impact factor: 1.547

2.  An analysis of the air-bone gap closure obtained by a crimping and a non-crimping titanium stapes prosthesis in otosclerosis.

Authors:  Rinze A Tange; Wilko Grolman
Journal:  Auris Nasus Larynx       Date:  2007-11-19       Impact factor: 1.863

3.  Committee on Hearing and Equilibrium guidelines for the evaluation of results of treatment of conductive hearing loss. AmericanAcademy of Otolaryngology-Head and Neck Surgery Ffoundation, Inc.

Authors: 
Journal:  Otolaryngol Head Neck Surg       Date:  1995-09       Impact factor: 3.497

4.  The loose wire syndrome.

Authors:  T M McGee
Journal:  Laryngoscope       Date:  1981-09       Impact factor: 3.325

5.  Causes of conductive hearing loss after stapedectomy or stapedotomy: a prospective study of 279 consecutive surgical revisions.

Authors:  S George Lesinski
Journal:  Otol Neurotol       Date:  2002-05       Impact factor: 2.311

6.  Retrospective analysis of early postoperative hearing results obtained after stapedotomy with implantation of a new titanium stapes prosthesis.

Authors:  C L Zuur; A J G de Bruijn; R Lindeboom; R A Tange
Journal:  Otol Neurotol       Date:  2003-11       Impact factor: 2.311

  6 in total
  1 in total

1.  [Stapes surgery for otosclerosis using a new titanium prosthesis with a superelastic nitinol clip: First experiences].

Authors:  J Zirkler; T Rahne; S K Plontke
Journal:  HNO       Date:  2016-02       Impact factor: 1.284

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.