Literature DB >> 24410440

Serological diagnosis of dengue infection in blood plasma using long-range surface plasmon waveguides.

Wei Ru Wong1, Oleksiy Krupin, Shamala Devi Sekaran, Faisal Rafiq Mahamd Adikan, Pierre Berini.   

Abstract

We present a compact, cost-effective, label-free, real-time biosensor based on long-range surface plasmon polariton (LRSPP) gold (Au) waveguides for the detection of dengue-specific immunoglobulin M (IgM) antibody, and we demonstrate detection in actual patient blood plasma samples. Two surface functionalization approaches are proposed and demonstrated: a dengue virus serotype 2 (DENV-2) functionalized surface to capture dengue-specific IgM antibody in blood plasma and the reverse, a blood plasma functionalized surface to capture DENV-2. The results obtained via these two surface functionalization approaches are comparable to, or of greater quality, than those collected by conventional IgM antibody capture enzyme linked immunosorbent assay (MAC-ELISA). Our second functionalization approach was found to minimize nonspecific binding, thus improving the sensitivity and accuracy of the test. We also demonstrate reuse of the biosensors by regenerating the sensing surface down to the virus (or antibody) level or down to the bare Au.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24410440     DOI: 10.1021/ac403539k

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  8 in total

1.  Selective detection of bacteria in urine with a long-range surface plasmon waveguide biosensor.

Authors:  Paul Béland; Oleksiy Krupin; Pierre Berini
Journal:  Biomed Opt Express       Date:  2015-07-16       Impact factor: 3.732

2.  Optics: Leading lights.

Authors:  Elizabeth Gibney
Journal:  Nature       Date:  2015-02-12       Impact factor: 49.962

3.  Screen Printed Carbon Electrode Based Electrochemical Immunosensor for the Detection of Dengue NS1 Antigen.

Authors:  Om Parkash; Chan Yean Yean; Rafidah Hanim Shueb
Journal:  Diagnostics (Basel)       Date:  2014-11-20

4.  Long-Range Surface Plasmon-Polariton Waveguide Biosensors for Human Cardiac Troponin I Detection.

Authors:  Oleksiy Krupin; Pierre Berini
Journal:  Sensors (Basel)       Date:  2019-02-02       Impact factor: 3.576

5.  Development of peptide biosensor for the detection of dengue fever biomarker, nonstructural 1.

Authors:  Ji Hong Kim; Chae Hwan Cho; Myung Yi Ryu; Jong-Gil Kim; Sei-Jung Lee; Tae Jung Park; Jong Pil Park
Journal:  PLoS One       Date:  2019-09-25       Impact factor: 3.240

Review 6.  Advanced Waveguide Based LOC Biosensors: A Minireview.

Authors:  Muzafar A Kanjwal; Amal Al Ghaferi
Journal:  Sensors (Basel)       Date:  2022-07-21       Impact factor: 3.847

Review 7.  Diagnosis of Dengue Infection Using Conventional and Biosensor Based Techniques.

Authors:  Om Parkash; Rafidah Hanim Shueb
Journal:  Viruses       Date:  2015-10-19       Impact factor: 5.048

8.  Sensitive Detection of Dengue Virus Type 2 E-Proteins Signals Using Self-Assembled Monolayers/Reduced Graphene Oxide-PAMAM Dendrimer Thin Film-SPR Optical Sensor.

Authors:  Nur Alia Sheh Omar; Yap Wing Fen; Jaafar Abdullah; Yasmin Mustapha Kamil; Wan Mohd Ebtisyam Mustaqim Mohd Daniyal; Amir Reza Sadrolhosseini; Mohd Adzir Mahdi
Journal:  Sci Rep       Date:  2020-02-11       Impact factor: 4.379

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.