Literature DB >> 24403416

A level-crossing based QRS-detection algorithm for wearable ECG sensors.

Nassim Ravanshad, Hamidreza Rezaee-Dehsorkh, Reza Lotfi, Yong Lian.   

Abstract

In this paper, an asynchronous analog-to-information conversion system is introduced for measuring the RR intervals of the electrocardiogram (ECG) signals. The system contains a modified level-crossing analog-to-digital converter and a novel algorithm for detecting the R-peaks from the level-crossing sampled data in a compressed volume of data. Simulated with MIT-BIH Arrhythmia Database, the proposed system delivers an average detection accuracy of 98.3%, a sensitivity of 98.89%, and a positive prediction of 99.4%. Synthesized in 0.13 μm CMOS technology with a 1.2 V supply voltage, the overall system consumes 622 nW with core area of 0.136 mm (2), which make it suitable for wearable wireless ECG sensors in body-sensor networks.

Entities:  

Mesh:

Year:  2014        PMID: 24403416     DOI: 10.1109/JBHI.2013.2274809

Source DB:  PubMed          Journal:  IEEE J Biomed Health Inform        ISSN: 2168-2194            Impact factor:   5.772


  8 in total

1.  Sensor fusion methods for reducing false alarms in heart rate monitoring.

Authors:  Gabriel Borges; Valner Brusamarello
Journal:  J Clin Monit Comput       Date:  2015-10-06       Impact factor: 2.502

2.  Straightforward and robust QRS detection algorithm for wearable cardiac monitor.

Authors:  M Sabarimalai Manikandan; Barathram Ramkumar
Journal:  Healthc Technol Lett       Date:  2014-03-21

3.  FPGA Implementation of Heart Rate Monitoring System.

Authors:  D Panigrahy; M Rakshit; P K Sahu
Journal:  J Med Syst       Date:  2015-12-07       Impact factor: 4.460

Review 4.  From Pacemaker to Wearable: Techniques for ECG Detection Systems.

Authors:  Ashish Kumar; Rama Komaragiri; Manjeet Kumar
Journal:  J Med Syst       Date:  2018-01-11       Impact factor: 4.460

5.  Accurate detection of atrial fibrillation events with R-R intervals from ECG signals.

Authors:  Junbo Duan; Qing Wang; Bo Zhang; Chen Liu; Chenrui Li; Lei Wang
Journal:  PLoS One       Date:  2022-08-04       Impact factor: 3.752

Review 6.  A Review of Stimuli-Responsive Smart Materials for Wearable Technology in Healthcare: Retrospective, Perspective, and Prospective.

Authors:  Valentina Trovato; Silvia Sfameni; Giulia Rando; Giuseppe Rosace; Sebania Libertino; Ada Ferri; Maria Rosaria Plutino
Journal:  Molecules       Date:  2022-09-05       Impact factor: 4.927

7.  An Energy efficient application specific integrated circuit for electrocardiogram feature detection and its potential for ambulatory cardiovascular disease detection.

Authors:  Sanjeev Kumar Jain; Basabi Bhaumik
Journal:  Healthc Technol Lett       Date:  2016-01-26

Review 8.  ECG Monitoring Systems: Review, Architecture, Processes, and Key Challenges.

Authors:  Mohamed Adel Serhani; Hadeel T El Kassabi; Heba Ismail; Alramzana Nujum Navaz
Journal:  Sensors (Basel)       Date:  2020-03-24       Impact factor: 3.576

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.