Literature DB >> 24401427

Quantitative evaluation of besifloxacin ophthalmic suspension by HPLC, application to bioassay method and cytotoxicity studies.

Márcia C N Costa1, Amanda T Barden2, Juliana M M Andrade3, Tércio P Oppe2, Elfrides E S Schapoval2.   

Abstract

Besifloxacin (BSF) is a synthetic chiral fluoroquinolone developed for the topical treatment of ophthalmic infections. The present study reports the development and validation of a microbiological assay, applying the cylinder-plate method, for determination of BSF in ophthalmic suspension. To assess this methodology, the development and validation of the method was performed for the quantification of BSF by high performance liquid chromatography (HPLC). The HPLC method showed specificity, linearity in the range of 20-80 µg mL(-1) (r=0.9998), precision, accuracy and robustness. The microbiological method is based on the inhibitory effect of BSF upon the strain of Staphylococcus epidermidis ATCC 12228 used as a test microorganism. The bioassay validation method yielded excellent results and included linearity, precision, accuracy, robustness and selectivity. The assay results were treated statistically by analysis of variance (ANOVA) and were found to be linear (r=0.9974) in the range of 0.5-2.0 µg mL(-1), precise (inter-assay: RSD=0.84), accurate (101.4%), specific and robust. The bioassay and the previously validated high performance liquid chromatographic (HPLC) method were compared using Student's t test, which indicated that there was no statistically significant difference between these two methods. These results confirm that the proposed microbiological method can be used as routine analysis for the quantitative determination of BSF in an ophthalmic suspension. A preliminary stability study during the HPLC validation was performed and demonstrated that BSF is unstable under UV conditions. The photodegradation kinetics of BSF in water showed a first-order reaction for the drug product (ophthalmic suspension) and a second-order reaction for the reference standard (RS) under UVA light. UVA degraded samples of BSF were also studied in order to determine the preliminary in vitro cytotoxicity against mononuclear cells. The results indicated that BSF does not alter the cell membrane and has been considered non-toxic to human mononuclear cells in the experimental conditions tested.
© 2013 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Besifloxacin; Bioassay; Cytotoxicity; HPLC; Method validation

Mesh:

Substances:

Year:  2013        PMID: 24401427     DOI: 10.1016/j.talanta.2013.10.051

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  4 in total

1.  Inactivation of Polymyxin by Hydrolytic Mechanism.

Authors:  Jianhua Yin; Gang Wang; Dan Cheng; Jianv Fu; Juanping Qiu; Zhiliang Yu
Journal:  Antimicrob Agents Chemother       Date:  2019-05-24       Impact factor: 5.191

2.  In vitro toxic evaluation of two gliptins and their main impurities of synthesis.

Authors:  Camila F A Giordani; Sarah Campanharo; Nathalie R Wingert; Lívia M Bueno; Joanna W Manoel; Barbara Costa; Shanda Cattani; Marcelo Dutra Arbo; Solange Cristina Garcia; Cássia Virginia Garcia; Nádia Maria Volpato; Elfrides Eva Scherman Schapoval; Martin Steppe
Journal:  BMC Pharmacol Toxicol       Date:  2019-12-19       Impact factor: 2.483

3.  Development and Validation of Different Ultraviolet-Spectrophotometric Methods for the Estimation of Besifloxacin in Different Simulated Body Fluids.

Authors:  C L Singh; A Singh; S Kumar; M Kumar; P K Sharma; D K Majumdar
Journal:  Indian J Pharm Sci       Date:  2015 Jul-Aug       Impact factor: 0.975

4.  A novel method to detect bacterial resistance to disinfectants.

Authors:  Xiao-Feng He; Hui-Jie Zhang; Jin-Gui Cao; Fang Liu; Jian-Kang Wang; Wen-Jie Ma; Wen Yin
Journal:  Genes Dis       Date:  2017-07-08
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.