Literature DB >> 24399082

The human ear canal: investigation of its suitability for monitoring photoplethysmographs and arterial oxygen saturation.

K Budidha1, P A Kyriacou.   

Abstract

For the last two decades, pulse oximetry has been used as a standard procedure for monitoring arterial oxygen saturation (SpO2). However, SpO2 measurements made from extremities such as the finger, ear lobe and toes become susceptible to inaccuracies when peripheral perfusion is compromised. To overcome these limitations, the external auditory canal has been proposed as an alternative monitoring site for estimating SpO2, on the hypothesis that this central site will be better perfused. Therefore, a dual wavelength optoelectronic probe along with a processing system was developed to investigate the suitability of measuring photoplethysmographic (PPG) signals and SpO2 in the human auditory canal. A pilot study was carried out in 15 healthy volunteers to validate the feasibility of measuring PPGs and SpO2 from the ear canal (EC), and comparative studies were performed by acquiring the same signals from the left index finger (LIF) and the right index finger (RIF) in conditions of induced peripheral vasoconstriction (right hand immersion in ice water). Good quality baseline PPG signals with high signal-to-noise ratio were obtained from the EC, the LIF and the RIF sensors. During the ice water immersion, significant differences in the amplitude of the red and infrared PPG signals were observed from the RIF and the LIF sensors. The average drop in amplitude of red and infrared PPG signals from the RIF was 52.7% and 58.3%. Similarly, the LIF PPG signal amplitudes have reduced by 47.52% and 46.8% respectively. In contrast, no significant changes were seen in the red and infrared EC PPG amplitude measurements, which changed by +2.5% and -1.2% respectively. The RIF and LIF pulse oximeters have failed to estimate accurate SpO2 in seven and four volunteers respectively, while the EC pulse oximeter has only failed in one volunteer. These results suggest that the EC may be a suitable site for reliable monitoring of PPGs and SpO2s even in the presence of peripheral vasoconstriction.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24399082     DOI: 10.1088/0967-3334/35/2/111

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  8 in total

1.  Investigation of peripheral photoplethysmographic morphology changes induced during a hand-elevation study.

Authors:  Michelle Hickey; Justin P Phillips; Panayiotis A Kyriacou
Journal:  J Clin Monit Comput       Date:  2015-08-29       Impact factor: 2.502

2.  Wearable Photoplethysmography for Cardiovascular Monitoring.

Authors:  Peter H Charlton; Panicos A Kyriaco; Jonathan Mant; Vaidotas Marozas; Phil Chowienczyk; Jordi Alastruey
Journal:  Proc IEEE Inst Electr Electron Eng       Date:  2022-03-11       Impact factor: 10.961

3.  In vivo investigation of ear canal pulse oximetry during hypothermia.

Authors:  K Budidha; P A Kyriacou
Journal:  J Clin Monit Comput       Date:  2017-01-27       Impact factor: 2.502

4.  In-Ear Pulse Rate Measurement: A Valid Alternative to Heart Rate Derived from Electrocardiography?

Authors:  Stefanie Passler; Niklas Müller; Veit Senner
Journal:  Sensors (Basel)       Date:  2019-08-21       Impact factor: 3.576

5.  Hearables: New Perspectives and Pitfalls of In-Ear Devices for Physiological Monitoring. A Scoping Review.

Authors:  Michela Masè; Alessandro Micarelli; Giacomo Strapazzon
Journal:  Front Physiol       Date:  2020-10-16       Impact factor: 4.566

6.  Investigation of Photoplethysmography Behind the Ear for Pulse Oximetry in Hypoxic Conditions with a Novel Device (SPYDR).

Authors:  Brian Bradke; Bradford Everman
Journal:  Biosensors (Basel)       Date:  2020-04-04

7.  Earable POCER: Development of a Point-of-Care Ear Sensor for Respiratory Rate Measurement.

Authors:  Kazuhiro Taniguchi; Atsushi Nishikawa
Journal:  Sensors (Basel)       Date:  2018-09-10       Impact factor: 3.576

8.  Photoplethysmography for Quantitative Assessment of Sympathetic Nerve Activity (SNA) During Cold Stress.

Authors:  Karthik Budidha; Panayiotis A Kyriacou
Journal:  Front Physiol       Date:  2019-01-09       Impact factor: 4.566

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.