Literature DB >> 24396382

Is sheep lumbar spine a suitable alternative model for human spinal researches? Morphometrical comparison study.

Mahmoud Mageed1, Dagmar Berner2, Henriette Jülke3, Christian Hohaus4, Walter Brehm2, Kerstin Gerlach2.   

Abstract

Sheep are commonly used as a model for human spinal orthopaedic research due to their similarity in morphological and biomechanical features. This study aimed to document the volumes of vertebral bodies and compare the generated results as well as morphometry of the sheep lumbar spine to human published data. For this purpose, computed tomography scans were carried out on five adult Merino sheep under general anaesthesia. Transverse 5 mm thick images were acquired from L1 to L6 using a multi-detector-row helical CT scanner. Volume measurements were performed with dedicated software. Four spinal indices and Pavlov's ratio were calculated. Thereafter, the generated data were compared to published literature on humans. The mean vertebral body volume showed an increase towards the caudal vertebrae, but there were no significant differences between the vertebral levels (P>0.05). Compared to humans, sheep vertebral body volumes were 48.6% smaller. The comparison of absolute values between both species revealed that sheep had smaller, longer and narrower vertebral bodies, thinner intervertebral discs, narrower spinal canal, longer transverse processes, shorter dorsal spinous processes and narrower, higher pedicles with more lateral angulations. The comparison of the spinal indices showed a good similarity to human in terms of the vertebral endplates and spinal canal. The results of this study may be helpful for using the sheep as a model for human orthopaedic spinal research if anatomical differences are taken into account.

Entities:  

Keywords:  Comparative anatomy; human lumbar spine; ovine; spinal index; vertebral body volume

Year:  2013        PMID: 24396382      PMCID: PMC3879336          DOI: 10.5625/lar.2013.29.4.183

Source DB:  PubMed          Journal:  Lab Anim Res        ISSN: 1738-6055


  28 in total

1.  Rapid estimation of the vertebral body volume: a combination of the Cavalieri principle and computed tomography images.

Authors:  Ersan Odaci; Bünyamin Sahin; Osman Fikret Sonmez; Süleyman Kaplan; Orhan Bas; Sait Bilgic; Yüksel Bek; Hayati Ergür
Journal:  Eur J Radiol       Date:  2003-12       Impact factor: 3.528

2.  In vitro spinal arthrodesis implant mechanical testing protocols.

Authors:  R B Ashman; J E Bechtold; W T Edwards; C E Johnston; P C McAfee; A F Tencer
Journal:  J Spinal Disord       Date:  1989-12

3.  Interobserver discrepancies in distance measurements from lumbar spine CT scans.

Authors:  G J Beers; A P Carter; B E Leiter; S P Tilak; R R Shah
Journal:  AJR Am J Roentgenol       Date:  1985-02       Impact factor: 3.959

4.  Are sheep spines a valid biomechanical model for human spines?

Authors:  H J Wilke; A Kettler; L E Claes
Journal:  Spine (Phila Pa 1976)       Date:  1997-10-15       Impact factor: 3.468

5.  Disc chondrocyte transplantation in a canine model: a treatment for degenerated or damaged intervertebral disc.

Authors:  Timothy Ganey; Jeanette Libera; Verena Moos; Olivera Alasevic; Karl-Gerd Fritsch; Hans Joerg Meisel; William C Hutton
Journal:  Spine (Phila Pa 1976)       Date:  2003-12-01       Impact factor: 3.468

6.  Changes in endplate vascularity after an outer anulus tear in the sheep.

Authors:  R J Moore; O L Osti; B Vernon-Roberts; R D Fraser
Journal:  Spine (Phila Pa 1976)       Date:  1992-08       Impact factor: 3.468

7.  Experiences with sheep as an animal model for shoulder surgery: strengths and shortcomings.

Authors:  A Simon Turner
Journal:  J Shoulder Elbow Surg       Date:  2007-05-15       Impact factor: 3.019

Review 8.  The potential of sheep for the study of osteopenia: current status and comparison with other animal models.

Authors:  E Newman; A S Turner; J D Wark
Journal:  Bone       Date:  1995-04       Impact factor: 4.398

Review 9.  Experimental models of fracture repair.

Authors:  D M Nunamaker
Journal:  Clin Orthop Relat Res       Date:  1998-10       Impact factor: 4.176

10.  Statistical diagnosis of lumbar spine disorders using computerized patient pain drawings.

Authors:  N H Mann; M D Brown; I Enger
Journal:  Comput Biol Med       Date:  1991       Impact factor: 4.589

View more
  4 in total

1.  Collateral effects of targeting the nucleus pulposus via a transpedicular or transannular surgical route: a combined X-ray, MRI, and histological long-term descriptive study in sheep.

Authors:  Cyrille Decante; Johann Clouet; Antoine Hamel; Luc Le Fournier; Olivier Gauthier; Dominique Rouleau; Julie Lesoeur; Boris Halgand; Catherine Le Visage; Jérôme Guicheux; Marion Fusellier
Journal:  Eur Spine J       Date:  2020-09-18       Impact factor: 3.134

2.  Neurologic Complications Associated with Transdermal Placement of Intrathecal Catheters in Sheep.

Authors:  Gabrielle C Musk; Nolan J McDonnell; Mark Newman; Matthew W Kemp
Journal:  Comp Med       Date:  2018-04-19       Impact factor: 0.982

3.  Comparison and optimization of sheep in vivo intervertebral disc injury model.

Authors:  Caroline Constant; Warren W Hom; Dirk Nehrbass; Eric-Norman Carmel; Christoph E Albers; Moritz C Deml; Dominic Gehweiler; Yunsoo Lee; Andrew Hecht; Sibylle Grad; James C Iatridis; Stephan Zeiter
Journal:  JOR Spine       Date:  2022-04-22

Review 4.  Zebrafish for Personalized Regenerative Medicine; A More Predictive Humanized Model of Endocrine Disease.

Authors:  Babak Arjmand; Akram Tayanloo-Beik; Najmeh Foroughi Heravani; Setareh Alaei; Moloud Payab; Sepideh Alavi-Moghadam; Parisa Goodarzi; Mahdi Gholami; Bagher Larijani
Journal:  Front Endocrinol (Lausanne)       Date:  2020-07-17       Impact factor: 5.555

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.