An MRI-guided PET Partial Volume Correction Method.

Hesheng Wang1, Baowei Fei2.   

Abstract

Accurate quantification of positron emission tomography (PET) is important for diagnosis and assessment of cancer treatment. The low spatial resolution of PET imaging induces partial volume effect to PET images that biases quantification. A PET partial volume correction method is proposed using high-resolution, anatomical information from magnetic resonance images (MRI). The corrected PET is pursued by removing the convolution of PET point spread function (PSF) and by preserving edges present in PET and the aligned MR images. The correction is implemented in a Bayesian's deconvolution framework that is minimized by a conjugate gradient method. The method is evaluated on simulated phantom and brain PET images. The results show that the method effectively restores 102 ± 7% of the true PET activity with a size of greater than the full-width at half maximum of the point spread function. We also applied the method to synthesized brain PET data. The method does not require prior information about tracer activity within tissue regions. It can offer a partial volume correction method for various PET applications and can be particularly useful for combined PET/MRI studies.

Entities:  

Keywords:  PET/MRI; deconvolution; partial volume effects

Year:  2009        PMID: 24386530      PMCID: PMC3877222          DOI: 10.1117/12.812474

Source DB:  PubMed          Journal:  Proc SPIE Int Soc Opt Eng        ISSN: 0277-786X


  7 in total

1.  Importance of partial-volume correction in brain PET studies.

Authors:  F Fazio; D Perani
Journal:  J Nucl Med       Date:  2000-11       Impact factor: 10.057

2.  Correction of partial-volume effect for PET striatal imaging: fast implementation and study of robustness.

Authors:  Vincent Frouin; Claude Comtat; Anthonin Reilhac; Marie-Claude Grégoire
Journal:  J Nucl Med       Date:  2002-12       Impact factor: 10.057

Review 3.  Partial-volume effect in PET tumor imaging.

Authors:  Marine Soret; Stephen L Bacharach; Irène Buvat
Journal:  J Nucl Med       Date:  2007-05-15       Impact factor: 10.057

4.  A nonlinear spatially variant object-dependent system model for prediction of partial volume effects and scatter in PET.

Authors:  C H Chen; R F Muzic; A D Nelson; L P Adler
Journal:  IEEE Trans Med Imaging       Date:  1998-04       Impact factor: 10.048

5.  Simultaneous recovery of size and radioactivity concentration of small spheroids with PET data.

Authors:  C H Chen; R F Muzic; A D Nelson; L P Adler
Journal:  J Nucl Med       Date:  1999-01       Impact factor: 10.057

6.  Correction for partial volume effects in PET: principle and validation.

Authors:  O G Rousset; Y Ma; A C Evans
Journal:  J Nucl Med       Date:  1998-05       Impact factor: 10.057

7.  Evaluation of anatomy based reconstruction for partial volume correction in brain FDG-PET.

Authors:  Kristof Baete; Johan Nuyts; Koen Van Laere; Wim Van Paesschen; Sarah Ceyssens; Liesbet De Ceuninck; Olivier Gheysens; Annemarie Kelles; Jimmy Van den Eynden; Paul Suetens; Patrick Dupont
Journal:  Neuroimage       Date:  2004-09       Impact factor: 6.556

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.