Literature DB >> 24381704

Efficacy of a reduced electroencephalography electrode array for detection of seizures.

Mark N Rubin1, Oliver J Jeffery2, Jennifer E Fugate3, Jeffery W Britton2, Gregory D Cascino2, Gregory A Worrell2, Sara E Hocker3, Eelco F Wijdicks3, Alejandro A Rabinstein3.   

Abstract

BACKGROUND: The expertise required for proper electroencephalography (EEG) setup can make the 10-20 array unwieldy in the hospital setting. There may be a role for an EEG array with reduced leads to improve the efficiency of inpatient practice.
METHODS: Clips from 100 EEG records, 50 ictal and 50 non-ictal, in adult inpatients from January 1, 2007, to January 1, 2012, were retrospectively reviewed and selected for digital lead reduction and blind review. Two epileptologists reviewed these tracings and documented the presence of seizures and severe disturbance of background. The reduced array included 7 leads spanning the scalp. Three different montages were available. Sensitivity and specificity of the reduced array were calculated using the formal EEG report as the comparison standard.
RESULTS: For the detection of any seizure, the reduced array EEG had a sensitivity of 70% and specificity of 96%. Sensitivity for identifying encephalopathic patterns was 62% and specificity was 86%. Focal seizures were more readily identified by the reduced array (20 of 25) than were generalized ictal patterns (13 of 25).
CONCLUSION: The reduced electrode array was insufficiently sensitive to seizure detection. Reducing EEG leads might not be a preferred means of optimizing hospital EEG efficiency.

Entities:  

Keywords:  EEG; array; hospital; montage; reduced; seizure

Year:  2014        PMID: 24381704      PMCID: PMC3869310          DOI: 10.1177/1941874413507930

Source DB:  PubMed          Journal:  Neurohospitalist        ISSN: 1941-8744


  7 in total

1.  Single-channel amplitude integrated EEG recording for the identification of epileptic seizures by nonexpert physicians in the adult acute care setting.

Authors:  Rainer Nitzschke; Jakob Müller; Ria Engelhardt; Gunter N Schmidt
Journal:  J Clin Monit Comput       Date:  2011-10-19       Impact factor: 2.502

2.  EEG outside the hairline: detection of epileptiform abnormalities.

Authors:  S L Bridgers; J S Ebersole
Journal:  Neurology       Date:  1988-01       Impact factor: 9.910

Review 3.  Continuous EEG monitoring in the neuroscience intensive care unit and emergency department.

Authors:  K G Jordan
Journal:  J Clin Neurophysiol       Date:  1999-01       Impact factor: 2.177

4.  A quick and reliable EEG montage for the detection of seizures in the critical care setting.

Authors:  Ioannis Karakis; Georgia D Montouris; James A D Otis; Laurie M Douglass; Rinat Jonas; Naymee Velez-Ruiz; Kesha Wilford; Patricio S Espinosa
Journal:  J Clin Neurophysiol       Date:  2010-04       Impact factor: 2.177

5.  Assessment of hairline EEG as a screening tool for nonconvulsive status epilepticus.

Authors:  Brad J Kolls; Aatif M Husain
Journal:  Epilepsia       Date:  2007-04-13       Impact factor: 5.864

Review 6.  Continuous EEG and evoked potential monitoring in the neuroscience intensive care unit.

Authors:  K G Jordan
Journal:  J Clin Neurophysiol       Date:  1993-10       Impact factor: 2.177

7.  Seizure detection with a commercially available bedside EEG monitor and the subhairline montage.

Authors:  G Bryan Young; Michael D Sharpe; Martin Savard; Eyad Al Thenayan; Loretta Norton; Corrine Davies-Schinkel
Journal:  Neurocrit Care       Date:  2009-12       Impact factor: 3.210

  7 in total
  6 in total

Review 1.  Electroencephalography in survivors of cardiac arrest: comparing pre- and post-therapeutic hypothermia eras.

Authors:  Amy Z Crepeau; Jeffrey W Britton; Jennifer E Fugate; Alejandro A Rabinstein; Eelco F Wijdicks
Journal:  Neurocrit Care       Date:  2015-02       Impact factor: 3.210

Review 2.  Infection Prevention: 2020 Review and Update for Neurodiagnostic Technologists.

Authors:  Anna M Bonner; Petra Davidson
Journal:  Neurodiagn J       Date:  2020-01-22

3.  Simplified frontal EEG in adults under veno-arterial extracorporeal membrane oxygenation.

Authors:  Cyril Touchard; Jérôme Cartailler; Geoffroy Vellieux; Etienne de Montmollin; Pierre Jaquet; Ruben Wanono; Jean Reuter; Marylou Para; Lila Bouadma; Jean-François Timsit; Marie-Pia d'Ortho; Nathalie Kubis; Anny Rouvel Tallec; Romain Sonneville
Journal:  Ann Intensive Care       Date:  2021-05-13       Impact factor: 6.925

4.  Rapid diagnosis of nonconvulsive status epilepticus using reduced-lead electroencephalography.

Authors:  Jay M Brenner; Paul Kent; Susan M Wojcik; William Grant
Journal:  West J Emerg Med       Date:  2015-04-06

5.  Diagnostic utility of eight-channel EEG for detecting generalized or hemispheric seizures and rhythmic periodic patterns.

Authors:  Kapil Gururangan; Babak Razavi; Josef Parvizi
Journal:  Clin Neurophysiol Pract       Date:  2018-03-26

6.  Practical Considerations When Performing Neurodiagnostic Studies on Patients with COVID-19 and Other Highly Virulent Diseases.

Authors:  Seline Haines; Amy Caccamo; Fonda Chan; German Galaso; Alexis Catinchi; Puneet K Gupta
Journal:  Neurodiagn J       Date:  2020-05-06
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.