Literature DB >> 20234318

A quick and reliable EEG montage for the detection of seizures in the critical care setting.

Ioannis Karakis1, Georgia D Montouris, James A D Otis, Laurie M Douglass, Rinat Jonas, Naymee Velez-Ruiz, Kesha Wilford, Patricio S Espinosa.   

Abstract

Obtaining an emergent EEG for the diagnosis of nonconvulsive status epilepticus and conconvulsive seizures in the intensive care unit raises logistic problems in most hospitals. Previous studies have looked into the hairline EEG for a broader population than the critically ill, with controversial conclusions. The authors created a montage sufficiently simple to be performed and interpreted by residents and rapidly achievable to meet the time constraints of a busy on-call schedule. Seven electrodes (Fp1, Fp2, T3, T4, O1, O2, and Cz), easily applied without the need for tape measure by using only anatomic landmarks (pupils, ears, vertex, and inion), were used to configure three different montages: double diamond, circumferential, and Cz referential. EEG records obtained with the full 10-20 system in critically ill patients were reformatted into these montages and reviewed retrospectively independently by neurology attending physicians with expertise in EEG interpretation and senior neurology residents. A comparison was done with the previously studied hairline EEG. The average sensitivity of the study montage for seizure detection was 92.5%, whereas the average specificity was 93.5%. These results suggest that the seven-electrode montage could potentially be a quick and reliable EEG montage for the detection of seizures in the intensive care unit, when technical support is not available. Further prospective studies are required to validate these promising results in a larger population sample.

Entities:  

Mesh:

Year:  2010        PMID: 20234318     DOI: 10.1097/WNP.0b013e3181d649e4

Source DB:  PubMed          Journal:  J Clin Neurophysiol        ISSN: 0736-0258            Impact factor:   2.177


  13 in total

Review 1.  Recommendations on the use of EEG monitoring in critically ill patients: consensus statement from the neurointensive care section of the ESICM.

Authors:  Jan Claassen; Fabio S Taccone; Peter Horn; Martin Holtkamp; Nino Stocchetti; Mauro Oddo
Journal:  Intensive Care Med       Date:  2013-05-08       Impact factor: 17.440

2.  Successful treatment of non-convulsive status epilepticus diagnosed using bedside monitoring by a combination of amplitude-integrated and two-channel simplified electroencephalography.

Authors:  Satoshi Egawa; Toru Hifumi; Kenya Kawakita; Arisa Manabe; Hikari Matumura; Tomoya Okazaki; Hideyuki Hamaya; Natuyo Shinohara; Hajime Shishido; Koshiro Takano; Yuko Abe; Masanobu Hagiike; Yasuhiro Kuroda
Journal:  Acute Med Surg       Date:  2015-08-27

3.  Efficacy of a reduced electroencephalography electrode array for detection of seizures.

Authors:  Mark N Rubin; Oliver J Jeffery; Jennifer E Fugate; Jeffery W Britton; Gregory D Cascino; Gregory A Worrell; Sara E Hocker; Eelco F Wijdicks; Alejandro A Rabinstein
Journal:  Neurohospitalist       Date:  2014-01

4.  Guiding Antiepileptic Therapy in a Pediatric Patient with Severe Meningoencephalitis and Decompressive Craniectomy with the Use of Amplitude-Integrated Electroencephalography.

Authors:  Karl F Schettler; Beatrice Heineking; Silvia Fernandez-Rodriguez; Angelika Pilger; Nikolaus Alexander Haas
Journal:  J Pediatr Intensive Care       Date:  2016-08-08

5.  Factors related to delays in pre-hospital management of status epilepticus.

Authors:  Leena Kämppi; Harri Mustonen; Seppo Soinila
Journal:  Neurocrit Care       Date:  2015-02       Impact factor: 3.210

Review 6.  Structure and Outcomes of Educational Programs for Training Non-electroencephalographers in Performing and Screening Adult EEG: A Systematic Review.

Authors:  Julie Kromm; Kirsten M Fiest; Ayham Alkhachroum; Colin Josephson; Andreas Kramer; Nathalie Jette
Journal:  Neurocrit Care       Date:  2021-02-16       Impact factor: 3.210

Review 7.  Neurocritical care update.

Authors:  Yasuhiro Kuroda
Journal:  J Intensive Care       Date:  2016-05-28

8.  Diagnostic Reliability of Headset-Type Continuous Video EEG Monitoring for Detection of ICU Patterns and NCSE in Patients with Altered Mental Status with Unknown Etiology.

Authors:  Satoshi Egawa; Toru Hifumi; Hidetoshi Nakamoto; Yasuhiro Kuroda; Yuichi Kubota
Journal:  Neurocrit Care       Date:  2020-02       Impact factor: 3.210

Review 9.  Electrophysiologic monitoring in acute brain injury.

Authors:  Jan Claassen; Paul Vespa
Journal:  Neurocrit Care       Date:  2014-12       Impact factor: 3.210

Review 10.  Clinical review: neuromonitoring - an update.

Authors:  Nino Stocchetti; Peter Le Roux; Paul Vespa; Mauro Oddo; Giuseppe Citerio; Peter J Andrews; Robert D Stevens; Tarek Sharshar; Fabio S Taccone; Jean-Louis Vincent
Journal:  Crit Care       Date:  2013-01-15       Impact factor: 9.097

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.